90 research outputs found

    Assessing mandibular body changes in growing subjects: a comparison of CBCT and reconstructed lateral cephalogram measurements

    Get PDF
    The aim of this study is to compare cone-beam computed tomography (CBCT) and bi-dimensional reconstructed lateral cephalograms (RLCs) in assessing mandibular body length and growth and to evaluate how mandibular reshaping influences the error in measuring mandibular body growth in bi-dimensional radiographs. Twenty-five patients with two CBCT scans taken at a mean distance of 2.21\u2009\ub1\u20090.5 years were selected. The following measurements were performed: right and left mandibular body length at each point in time, mandibular growth, inter-gonial distance and mandibular symphyseal angle. From each CBCT, an RLC was obtained, and mandibular body length and growth were measured. Data analysis revealed a statistically and clinically significant difference in CBCT and RLC regarding the mandibular length of each patient at each point in time. However, mandibular growth was almost identical. A linear regression was performed to predict growth distortion between RLCs and CBCT depending on the ratio between transverse and sagittal mandibular growth. The expected maximum and minimum distortion, however, appeared not to be significant. In fact, a second linear regression model and a Bland-Altman test revealed a strong correlation between measurements of average mandibular body growth by CBCT and RLCs. As the same distortion occurs in the first and second RLCs, bi-dimensional radiographs remain the method of choice in evaluating mandibular body growth

    Comparison of a tridimensional cephalometric analysis performed on 3T-MRI compared with CBCT : a pilot study in adults

    Get PDF
    OBJECTIVE: Since the introduction of cone-beam computed tomography (CBCT) in dentistry, this technology has enabled distortion-free three-dimensional cephalometric analysis for orthodontic and orthognathic surgery diagnosis. However, CBCT is associated with significantly higher radiation exposure than traditional routine bidimensional examinations for orthodontic diagnosis, although low-dose protocols have markedly reduced radiation exposure over time. The objective of this preliminary feasibility study is to compare the accuracy and diagnostic capabilities of an already-validated three-dimensional cephalometric analysis on CBCT to those of an analysis on 3-T magnetic resonance imaging (3T-MRI) to assess whether the latter can deliver a comparable quality of information while avoiding radiation exposure. MATERIALS AND METHODS: In order to test the feasibility of three-dimensional cephalometry on 3T-MRI, 18 subjects (4 male; 14 female) with mean age 37.8\u2009\ub1\u2009SD 10.2, who had undergone both maxillofacial CBCT and maxillofacial 3T-MRI for various purposes within 1 month, were selected from the archive of the Department of Dentistry and Maxillofacial Surgery of Fondazione Ospedale Policlinico Maggiore, IRCCS, Milano, Italy. A three-dimensional cephalometric analysis composed of ten midsagittal and four bilateral landmarks and 24 measurements (11 angular, 13 linear) was performed on both scans using Mimics Research\uae v. 17.0 (NV, Technologielaan 15, 3001 Leuven, Belgium). Cephalometric analysis was performed twice by two independent orthodontists for each scan, and each orthodontist repeated the measurements 3 weeks later. Statistical analysis was performed with SPSS\uae 20.00 for Windows (IBM\uae Corporation, Sommers, NY, USA). A Bland-Altman test for each cephalometric value was performed to assess the agreement between the procedures. The intraclass correlation coefficient (ICC) was used to assess interobserver and intraobserver reliability. The coefficient of variation was used to evaluate precision. RESULTS: Both procedures showed good reliability, with mean intraobserver ICCs of 0.977/0.971 for CBCT and 0.881/0.912 for MRI. The average interobserver ICCs were 0.965 for CBCT and 0.833 for MRI. A Bland-Altman analysis for the cephalometric tracing revealed a similar range of agreement between the two modalities; the bias range (mean\u2009\ub1\u2009SD) was -\u20090.25-0.66\u2009mm (0.174\u2009\ub1\u20090.31) for distances and -\u20090.41-0.54\ub0 (0.12\u2009\ub1\u20090.33) for angles. CONCLUSIONS: Within the main limitation of this pilot study, that is, the small sample, it is possible to state that cephalometric measurements on 3T-MRI seem to possess adequate reliability and repeatability and that they show satisfying agreement with values measured on CBCTs. An MRI examination does not expose patients to ionizing radiation and could provide an alternative to CBCT for three-dimensional cephalometrics in the future

    Isolation and characterization of buccal fat pad and dental pulp mscs from the same donor

    Get PDF
    Mesenchymal stem cells (MSCs) can be harvested from different sites in the oral cavity, representing a reservoir of cells useful for regenerative purposes. As direct comparisons between at least two types of MSCs deriving from the same patient are surprisingly rare in scientific literature, we isolated and investigated the osteoinductive potential of dental pulp stem cells (DPSCs) and buccal fat pad stem cells (BFPSCs). MSCs were isolated from the third molar dental pulp and buccal fat pads of 12 patients. The number of viable cells was quantified through manual count. Proliferation and osteodifferentiation assays, flow cytometry analysis of cell phenotypes, and osteocalcin release in vitro were performed. The isolation of BFPSCs and DPSCs was successful in 7 out of 12 (58%) and 3 out of 12 (25%) of retrieved samples, respectively. The yield of cells expressing typical stem cell markers and the level of proliferation were higher in BFPSCs than in DPSCs. Both BFP-SCs and DPSCs differentiated into osteoblast-like cells and were able to release a mineralized matrix. The release of osteocalcin, albeit greater for BFPSCs, did not show any significant difference between BFPSCs and DPSCs. The yield of MSCs depends on their site of origin as well as on the protocol adopted for their isolation. Our data show that BFP is a valuable source for the derivation of MSCs that can be used for regenerative treatments

    Estimation of percentage breast tissue density: comparison between digital mammography (2D full field digital mammography) and digital breast tomosynthesis according to different BI-RADS categories

    No full text
    OBJECTIVE: To compare breast density estimated from two-dimensional full-field digital mammography (2D FFDM) and from digital breast tomosynthesis (DBT) according to different Breast Imaging–Reporting and Data System (BI-RADS) categories, using automated software. METHODS: Institutional review board approval and written informed patient consent were obtained. DBT and 2D FFDM were performed in the same patients to allow within-patient comparison. A total of 160 consecutive patients (mean age: 50±14 years; mean body mass index: 22±3) were included to create paired data sets of 40 patients for each BI-RADS category. Automatic software (MedDensity(©), developed by Giulio Tagliafico) was used to compare the percentage breast density between DBT and 2D FFDM. The estimated breast percentage density obtained using DBT and 2D FFDM was examined for correlation with the radiologists' visual BI-RADS density classification. RESULTS: The 2D FFDM differed from DBT by 16.0% in BI-RADS Category 1, by 11.9% in Category 2, by 3.5% in Category 3 and by 18.1% in Category 4. These differences were highly significant (p<0.0001). There was a good correlation between the BI-RADS categories and the density evaluated using 2D FFDM and DBT (r=0.56, p<0.01 and r=0.48, p<0.01, respectively). CONCLUSION: Using DBT, breast density values were lower than those obtained using 2D FFDM, with a non-linear relationship across the BI-RADS categories. These data are relevant for clinical practice and research studies using density in determining the risk. ADVANCES IN KNOWLEDGE: On DBT, breast density values were lower than with 2D FFDM, with a non-linear relationship across the classical BI-RADS categories

    A Radon measuring technique with germanium detectors

    No full text
    • …
    corecore