266 research outputs found

    Analysis of demersal assemblages off the Tuscany and Latium coasts (north-western Mediterranean)

    Get PDF
    A four-year time series (1994-1997) of groundfish trawl surveys performed within the European Union Project "MEDITS" (Mediterranean International Trawl Surveys), was analysed to identify and describe the fish assemblages along the continental shelf and slope of Tuscany and Latium (Italy), in the north-western Mediterranean. Cluster analysis was used to group samples with similar species composition in terms of abundance, biomass and frequency of occurrence. Results allowed the identification of four to five broad assemblages along the depth gradient: a strictly coastal group (< 50 m depth), two groups in the upper and lower part of the continental shelf (essentially 50-200 m), an epibathyal group (200450 m) and a group derived from hauls made at depths greater than 450 in. Each assemblage corresponded to a faunistic association with relatively homogeneous and persistent species composition, biomass and density indices

    Feasibility study of adhesive bonding reinforcement by electrospun nanofibers

    Get PDF
    Abstract In previous works, the authors showed that the interleaving of an electrospun nylon nanofibrous mat at the interface between adjacent plies of a composite laminate increases the delamination strength. In particular, the nanomat acts a net-like reinforcing web, enabling a ply-to-ply bridging effect. This reinforcing property of the nanomats can be potentially used in other applications which need to improve the fracture resistance of interfaces, such as adhesive bonding. The present work analyses the feasibility of an electrospun polymeric nanomat as adhesive carrier and reinforcing web in industrial bonding. Thus the adhesive is used to pre-impregnate a nylon nanofibrous mat that is then placed at the interface between two metal pieces and then cured. The aim of the work is first to assess the effectiveness of this procedure, by comparison of the mode-I fracture toughness measured with DCB (Double Cantilever Beam) tests with and without the reinforcement in the adhesive layer. For this purpose, a 2024-T3 aluminum alloy will be bonded using a general purpose, one-part epoxy resin with low viscosity

    A novel random counts estimation method for PET using a symmetrical delayed window technique and random single event acquisition

    Get PDF
    We have developed a novel logic scheme for the estimation of the random count distribution based on a dual symmetrical delayed window technique. The solution has been applied to a dual head PET case. We have also implemented a new method for noise variance reduction in the random count distribution

    First full-beam PET acquisitions in proton therapy with a modular dual-head dedicated system

    Get PDF
    During particle therapy irradiation, positron emitters with half-lives ranging from 2 to 20 min are generated from nuclear processes. The half-lives are such that it is possible either to detect the positron signal in the treatment room using an in-beam positron emission tomography (PET) system, right after the irradiation, or to quickly transfer the patient to a close PET/CT scanner. Since the activity distribution is spatially correlated with the dose, it is possible to use PET imaging as an indirect method to assure the quality of the dose delivery. In this work, we present a new dedicated PET system able to operate in-beam. The PET apparatus consists in two 10 cm × 10 cm detector heads. Each detector is composed of four scintillating matrices of 23 × 23 LYSO crystals. The crystal size is 1.9 mm × 1.9 mm × 16 mm. Each scintillation matrix is read out independently with a modularized acquisition system. The distance between the two opposing detector heads was set to 20 cm. The system has very low dead time per detector area and a 3 ns coincidence window, which is capable to sustain high single count rates and to keep the random counts relatively low. This allows a new full-beam monitoring modality that includes data acquisition also while the beam is on. The PET system was tested during the irradiation at the CATANA (INFN, Catania, Italy) cyclotron-based proton therapy facility. Four acquisitions with different doses and dose rates were analysed. In all cases the random to total coincidences ratio was equal or less than 25%. For each measurement we estimated the accuracy and precision of the activity range on a set of voxel lines within an irradiated PMMA phantom. Results show that the inclusion of data acquired during the irradiation, referred to as beam-on data, improves both the precision and accuracy of the range measurement with respect to data acquired only after irradiation. Beam-on data alone are enough to give precisions better than 1 mm when at least 5 Gy are delivered

    Comparison of two dedicated 'in beam' PET systems via simultaneous imaging of (12)C-induced beta(+)-activity.

    Get PDF
    The selective energy deposition of hadrontherapy has led to a growing interest in quality assurance techniques such as 'in-beam' PET. Due to the current lack of commercial solutions, dedicated detectors need to be developed. In this paper, we compare the performances of two different 'in-beam' PET systems which were simultaneously operated during and after low energy carbon ion irradiation of PMMA phantoms at GSI Darmstadt. The results highlight advantages and drawbacks of a novel in-beam PET prototype against a long-term clinically operated tomograph for ion therapy monitoring

    Reprogrammable Acquisition Architecture for Dedicated Positron Emission Tomography

    Get PDF
    We have developed a flexible, cost-efficient PET architecture adaptPositron Emission Tomographyable to different applications and system geometries, such as positron emission mammography (PEM) and in-beam PET for dose delivery monitoring (ibPET). The acquisition system has been used to implement modularized dual planar detectors with very low front-end dead time, as required in PEM or in ibPET. The flexibility is obtained thanks to the FPGA-based, reprogrammable, TDC-less coincidence processor. The final goal is to propose an effective acquisition methodology and the construction of a compact, low-cost instrument able to provide early diagnosis and to improve the effectiveness of follow-up studies for smaller tumours with respect to those studied with present clinical equipment (e.g., whole-body PET, SPECT, or scintigraphy)

    First tests for an online treatment monitoring system with in-beam PET for proton therapy

    Full text link
    PET imaging is a non-invasive technique for particle range verification in proton therapy. It is based on measuring the beta+ annihilations caused by nuclear interactions of the protons in the patient. In this work we present measurements for proton range verification in phantoms, performed at the CNAO particle therapy treatment center in Pavia, Italy, with our 10 x 10 cm^2 planar PET prototype DoPET. PMMA phantoms were irradiated with mono-energetic proton beams and clinical treatment plans, and PET data were acquired during and shortly after proton irradiation. We created 1-D profiles of the beta+ activity along the proton beam-axis, and evaluated the difference between the proximal rise and the distal fall-off position of the activity distribution. A good agreement with FLUKA Monte Carlo predictions was obtained. We also assessed the system response when the PMMA phantom contained an air cavity. The system was able to detect these cavities quickly after irradiation.Comment: 11 pages, 6 figures, Proceedings for International Workshop on Radiation Imaging Detectors, 201

    A flexible acquisition system for modular dual head Positron Emission Mammography

    Get PDF
    We have developed a dedicated scanner for Positron Emission Mammography, equipped with a new detection architecture that enhances its flexibility and reduces dead time. The scanner is going to use Luthetium based scintillators, which offer good detection efficiency, and a novel modular acquisition system, capable of sustaining the high scintillation rate and being less sensitive to background radiation. The final goal is the construction of an instrument able to provide an early diagnosis and to improve the effectiveness of follow-up studies for smaller tumours with respect to those studied with present clinical equipment (e.g. PET, SPECT o scintigraphy) so as to be able to visualize and characterize breast lesions with diameters < 5 mm

    Characteristics of a prototype matrix of Silicon PhotoMultipliers (SiPM)

    Get PDF
    International audienceThis work reports on the electrical (static and dynamic) as well as on the optical characteristics of a prototype matrix of Silicon Photomultipliers (SiPM). The prototype matrix consists of 4 Ă— 4 SiPM's on the same substrat fabricated at FBK-irst (Trento, Italy). Each SiPM of the matrix has an area of 1 Ă— 1mm2 and it is composed of 625 microcells connected in parallel. Each microcell of the SiPM is a GM-APD (n+/p junction on P+ substrate) with an area of 40 Ă— 40 ÎĽm2 connected in series with its integrated polysilicon quenching resistance. The static characteristics as breakdown voltage, quenching resistance, post-breakdown dark current as well as the dynamic characteristics as gain and dark count rate have been analysed. The photon detection efficiency as a function of wavelength and operation voltage has been also estimated
    • …
    corecore