277 research outputs found

    Fast determination of coarse grained cell anisotropy and size in epithelial tissue images using Fourier transform

    Full text link
    Mechanical strain and stress play a major role in biological processes such as wound healing or morphogenesis. To assess this role quantitatively, fixed or live images of tissues are acquired at a cellular precision in large fields of views. To exploit these data, large numbers of cells have to be analyzed to extract cell shape anisotropy and cell size. Most frequently, this is performed through detailed individual cell contour determination, using so-called segmentation computer programs, complemented if necessary by manual detection and error corrections. However, a coarse grained and faster technique can be recommended in at least three situations. First, when detailed information on individual cell contours is not required, for instance in studies which require only coarse-grained average information on cell anisotropy. Second, as an exploratory step to determine whether full segmentation can be potentially useful. Third, when segmentation is too difficult, for instance due to poor image quality or too large a cell number. We developed a user-friendly, Fourier transform-based image analysis pipeline. It is fast (typically 10410^4 cells per minute with a current laptop computer) and suitable for time, space or ensemble averages. We validate it on one set of artificial images and on two sets of fully segmented images, one from a Drosophila pupa and the other from a chicken embryo; the pipeline results are robust. Perspectives include \textit{in vitro} tissues, non-biological cellular patterns such as foams, and xyzxyz stacks.Comment: 13 pages; 9 figure

    A migrating epithelial monolayer flows like a Maxwell viscoelastic liquid

    Full text link
    We perform a bidimensional Stokes experiment in an active cellular material: an autonomously migrating monolayer of Madin-Darby Canine Kidney (MDCK) epithelial cells flows around a circular obstacle within a long and narrow channel, involving an interplay between cell shape changes and neighbour rearrangements. Based on image analysis of tissue flow and coarse-grained cell anisotropy, we determine the tissue strain rate, cell deformation and rearrangement rate fields, which are spatially heterogeneous. We find that the cell deformation and rearrangement rate fields correlate strongly, which is compatible with a Maxwell viscoelastic liquid behaviour (and not with a Kelvin-Voigt viscoelastic solid behaviour). The value of the associated relaxation time is measured as τ=70±15\tau = 70 \pm 15~min, is observed to be independent of obstacle size and division rate, and is increased by inhibiting myosin activity. In this experiment, the monolayer behaves as a flowing material with a Weissenberg number close to one which shows that both elastic and viscous effects can have comparable contributions in the process of collective cell migration.Comment: 17 pages, 15 figure

    Fretting wear performances of multilayered PVD TiAlZrN/TiAlN/TiAl on AISI 4140 steel

    Get PDF
    Nowadays, most surface treatments are realized through vapor deposition techniques as thin hard coatings to guarantee; high surface hardness, low friction coefficient and improve wear resistance. Several experimental investigations have let to the development of a (TiAlCN/TiAlN/TiAl) and (TiAlZrN/TiAlN/TiAl) coatings in preference to the traditional TiN coating. In the current paper research conducted on fretting wear of a (TiAlCN/TiAlN/TiAl) and a (TiAlZrN/TiAlN/TiAl) multilayer coatings deposited by reactive DC (magnetron sputtering) of Ti-Al and Ti-Al-Zr alloys on AISI4140 steel. Fretting wear tests (20.000 cycles at 5 Hz) were conducted in ambient conditions, where the interaction between normal load and displacement amplitude determines the fretting regime. The influence of the normal load and displacement amplitude on the coefficients of instantaneous coefficient of friction and stabilized coefficient of friction is different from the two multilayer coated steels. The PVD coating (TiAlZrN/TiAlN/TiAl) reduces the friction. The worn volume of coated AISI4140 steel is sensitive to normal load and displacement amplitude. The relation between worn volume and cumulative dissipated energy was established for the two coated steels. The energetic fretting wear coefficients were also determined. A multilayer (TiAlZrN/TiAlN/TiAl) coating has a low energetic wear coefficient

    ‘Pole Test’ Measurements in Critical Leg Ischaemia

    Get PDF
    AbstractBackgroundFor the quantification of critical limb ischaemia (CLI) most vascular surgery units use sphygmo-manometric and transcutaneous oxygen pressure (TcPO2) measurements. However, measurements obtained by cuff-manometry can be overestimated especially in diabetic patients because of medial calcification that makes leg arteries less compressible. TcPO2 measurements present a considerable overlap in the values obtained for patients with different degrees of ischaemia and its reproducibility has been questioned. Arterial wall stiffness has less influence on the pole test, based on hydrostatic pressure derived by leg elevation, and this test seems to provide a reliable index of CLI.ObjectiveThe objective of this study was to evaluate the pole pressure test for detection of critical lower limb ischaemia, correlating results with cuff-manometry and transcutaneous oxygen pressure.DesignUniversity hospital-prospective study.Materials and methodsSeventy-four patients (83 legs) with rest pain or gangrene were evaluated by four methods: pole test, cuff-manometry, TcPO2 and arteriography. CLI was present if the following criteria were met: (a) important arteriographic lesions+rest pain with an ankle systolic pressure (ASP) ≤40mmHg and/or a TcPO2 ≤30mmHg, or (b) important arteriographic lesions+tissue loss with an ASP ≤60mmHg and/or a TcPO2 ≤40mmHg. Fifty-seven lower limbs met the criteria for CLI.ResultsMeasurements obtained by cuff-manometry were significantly higher to those obtained by pole test (mean pressure difference: 40mmHg, p<0.001). The difference between the two methods remained statistically significant for both diabetics (50.73, p<0.001) and non-diabetics (31.46, p<0.001). Mean TcPO2 value was 15.51mmHg and there was no important difference between patients with and without diabetes. Overall, there was a correlation between sphygmomanometry and pole test (r=0.481). The correlation persisted for patients without diabetes (r=0.581), but was not evident in patients with diabetes. Correlation between pole test and TcPO2 was observed only for patients with diabetes (r=0.444). There was no correlation between cuff-manometry and TcPO2. The pole test offered an accuracy of 88% for the detection of CLI. The sensitivity of this test was 95% and the specificity 73%

    Trace element contamination in the mine-affected stream sediments of Oued Rarai in north-western Tunisia. A river basin scale assessment

    Get PDF
    High-quality and accurate environmental investigations are essential for the evaluation of contamination and subsequent decision-making processes. A combination of environmental geochemical indices, multivariate analyses and geographic information system approach was successfully used to assess contamination status and source apportionment of trace elements (Ag, As, Cd, Cr, Cu, Hg, Ni, Pb, Sb, V and Zn) in surface stream sediments from the Oued Rarai basin in north-western Tunisia, containing various metal and metalloid ores. The contamination level reported in this study indicates a non-negligible potential ecological risk, mainly related to sediment transport along the river. Antimony (concentrations ranged from 0.02 to 297&nbsp;mg&nbsp;kg−1 and Igeo &gt; 5), arsenic (from 0.5 to 1490&nbsp;mg&nbsp;kg−1 and Igeo &gt; 5), lead (from 2.9 to 5150&nbsp;mg&nbsp;kg−1 and Igeo &gt; 5) mercury (from 0.05 to 54.4&nbsp;mg&nbsp;kg−1 and Igeo &gt; 5) and silver (from 0.05 to 9.4&nbsp;mg&nbsp;kg−1 and Igeo &gt; 5) showed the most crucial contamination. Besides, potential ecological risk index values were maximum for arsenic with a median of 302, indicating a very high to serious ecological risk (&gt; 160). Results from correlation analysis and principal component analysis revealed three main geochemical associations related to lithologic, tectonic and anthropogenic sources. V, Cr and Cu mainly originated from natural bedrock and soil. Ag and Cd were more controlled by both natural and mining enrichments. Mercury and Pb were mostly influenced by the ancient ore-related activities at the Oued Rarai site and north-east–south-west trending faults. Finally, Sb, As, Ni and Zn were largely controlled by the siliciclastic continental Neogene sequences. Finally, the physical and chemical dynamics of the watershed system, lithological properties, mineralisation, tectonic settings and mobilisation of subsurface sediments largely controlled both concentrations and spatial patterns of trace elements in the study basin. These results need to be considered in the strategies of suitable environmental management at former and current mining sites in north-western Tunisia

    Invariant vector fields and the prolongation method for supersymmetric quantum systems

    Full text link
    The kinematical and dynamical symmetries of equations describing the time evolution of quantum systems like the supersymmetric harmonic oscillator in one space dimension and the interaction of a non-relativistic spin one-half particle in a constant magnetic field are reviewed from the point of view of the vector field prolongation method. Generators of supersymmetries are then introduced so that we get Lie superalgebras of symmetries and supersymmetries. This approach does not require the introduction of Grassmann valued differential equations but a specific matrix realization and the concept of dynamical symmetry. The Jaynes-Cummings model and supersymmetric generalizations are then studied. We show how it is closely related to the preceding models. Lie algebras of symmetries and supersymmetries are also obtained.Comment: 37 pages, 7 table

    Fretting wear performances of multilayered PVD TiAlZrN/TiAlN/TiAl on AISI 4140 steel

    Get PDF
    Nowadays, most surface treatments are realized through vapor deposition techniques as thin hard coatings to guarantee; high surface hardness, low friction coefficient and improve wear resistance. Several experimental investigations have let to the development of a (TiAlCN/TiAlN/TiAl) and (TiAlZrN/TiAlN/TiAl) coatings in preference to the traditional TiN coating. In the current paper research conducted on fretting wear of a (TiAlCN/TiAlN/TiAl) and a (TiAlZrN/TiAlN/TiAl) multilayer coatings deposited by reactive DC (magnetron sputtering) of Ti-Al and Ti-Al-Zr alloys on AISI4140 steel. Fretting wear tests (20.000 cycles at 5 Hz) were conducted in ambient conditions, where the interaction between normal load and displacement amplitude determines the fretting regime. The influence of the normal load and displacement amplitude on the coefficients of instantaneous coefficient of friction and stabilized coefficient of friction is different from the two multilayer coated steels. The PVD coating (TiAlZrN/TiAlN/TiAl) reduces the friction. The worn volume of coated AISI4140 steel is sensitive to normal load and displacement amplitude. The relation between worn volume and cumulative dissipated energy was established for the two coated steels. The energetic fretting wear coefficients were also determined. A multilayer (TiAlZrN/TiAlN/TiAl) coating has a low energetic wear coefficient

    DepQBF 6.0: A Search-Based QBF Solver Beyond Traditional QCDCL

    Full text link
    We present the latest major release version 6.0 of the quantified Boolean formula (QBF) solver DepQBF, which is based on QCDCL. QCDCL is an extension of the conflict-driven clause learning (CDCL) paradigm implemented in state of the art propositional satisfiability (SAT) solvers. The Q-resolution calculus (QRES) is a QBF proof system which underlies QCDCL. QCDCL solvers can produce QRES proofs of QBFs in prenex conjunctive normal form (PCNF) as a byproduct of the solving process. In contrast to traditional QCDCL based on QRES, DepQBF 6.0 implements a variant of QCDCL which is based on a generalization of QRES. This generalization is due to a set of additional axioms and leaves the original Q-resolution rules unchanged. The generalization of QRES enables QCDCL to potentially produce exponentially shorter proofs than the traditional variant. We present an overview of the features implemented in DepQBF and report on experimental results which demonstrate the effectiveness of generalized QRES in QCDCL.Comment: 12 pages + appendix; to appear in the proceedings of CADE-26, LNCS, Springer, 201
    corecore