33 research outputs found

    Can Experienced Observers Differentiate between Lipoma and Well-Differentiated Liposarcoma Using Only MRI?

    Get PDF
    Well-differentiated liposarcoma represents a radiographic diagnostic dilemma. To determine the accuracy, interrater reliability, and relationship of stranding, nodularity, and size in the MRI differentiation of lipoma and well-differentiated liposarcoma, MRI scans of 60 patients with large (\u3e5 cm), deep, pathologically proven lipomas or well-differentiated liposarcomas were examined by 10 observers with subspecialty training blinded to diagnosis. Observers indicated whether the amount of stranding, nodularity, and size of each tumor suggested a benign or malignant diagnosis and rendered a diagnosis of lipoma or well-differentiated liposarcoma. The accuracy, reliability, and relationship of stranding, nodularity, and size to diagnosis were calculated for all samples. 69% of reader MRI diagnoses agreed with final pathology diagnosis (95% CI 65-73%). Readers tended to err choosing a diagnosis of liposarcoma, correctly identifying lipomas in 63% of cases (95% CI 58-69%) and liposarcomas in 75% of cases (95% CI 69-80%). Assessment of the relationship of stranding, nodularity, and size to correct diagnosis showed that the presence of each was associated with a decreased likelihood of a lipoma pathological diagnosis (P \u3c 0.01). While the radiographic diagnosis of lipoma or well-differentiated liposarcoma cannot be made with 100% certainty, experienced observers have a 69% chance of rendering a correct diagnosis

    Superficial Soft-Tissue Sarcomas Rarely Require Advanced Soft-Tissue Reconstruction Following Resection

    Get PDF
    Objective: Soft-tissue sarcomas are most frequently located deep within myofascial compartments. Superficial soft-tissue sarcomas (S-STS) are relatively less common and may be managed differently than deep sarcomas because generous resection margins are often possible without sacrificing critical structures. We sought to investigate the frequency and types of soft-tissue reconstructive procedures that are required following excision of S-STS. Methods: We reviewed 457 consecutively treated patients with S-STS with a minimum 2-year follow-up from our prospectively maintained database between 1989 and 2009. Results: Mean follow-up was 10.5 years (range, 2–23). Four hundred twenty-one tumors (91%) were excised with negative margins, 38 (8.3%) had microscopically positive margins, and three (0.7%) had grossly positive margins. One patient required an amputation. In 271 (58%) patients, the wounds were closed primarily. In comparison, 93 patients (20%) required a rotation flap, 70 (15%) required a split-thickness skin graft, and 23 (5%) underwent a free tissue transfer (ie, advanced reconstructive procedure). The overall complication rate was 12%, although 43% of patients undergoing free tissue transfer developed complications (P = 0.04). An unplanned excision before referral to our center was a risk factor for local recurrence (P = 0.03) when residual tumor was recovered in the reexcision specimen pathologically. Conclusions: Although concern about the morbidity associated with a free tissue transfer (ie, advanced reconstructive procedure) may potentially limit the adequacy of resection in some patients with S-STS, the results of this study showed that the majority of patients had complete excisions with negative margins and primary closure. Obtaining a negative margin when excising a known or suspected S-STS rarely requires an advanced reconstructive procedure and almost never results in loss of limb

    Can Experienced Observers Differentiate between Lipoma and Well-Differentiated Liposarcoma Using Only MRI?

    Get PDF
    Well-differentiated liposarcoma represents a radiographic diagnostic dilemma. To determine the accuracy, interrater reliability, and relationship of stranding, nodularity, and size in the MRI differentiation of lipoma and well-differentiated liposarcoma, MRI scans of 60 patients with large (>5 cm), deep, pathologically proven lipomas or well-differentiated liposarcomas were examined by 10 observers with subspecialty training blinded to diagnosis. Observers indicated whether the amount of stranding, nodularity, and size of each tumor suggested a benign or malignant diagnosis and rendered a diagnosis of lipoma or well-differentiated liposarcoma. The accuracy, reliability, and relationship of stranding, nodularity, and size to diagnosis were calculated for all samples. 69% of reader MRI diagnoses agreed with final pathology diagnosis (95% CI 65–73%). Readers tended to err choosing a diagnosis of liposarcoma, correctly identifying lipomas in 63% of cases (95% CI 58–69%) and liposarcomas in 75% of cases (95% CI 69–80%). Assessment of the relationship of stranding, nodularity, and size to correct diagnosis showed that the presence of each was associated with a decreased likelihood of a lipoma pathological diagnosis (P < 0.01). While the radiographic diagnosis of lipoma or well-differentiated liposarcoma cannot be made with 100% certainty, experienced observers have a 69% chance of rendering a correct diagnosis

    A mouse-human phase 1 co-clinical trial of a protease-activated fluorescent probe for imaging cancer

    Get PDF
    Local recurrence is a common cause of treatment failure for patients with solid tumors. Intraoperative detection of microscopic residual cancer in the tumor bed could be used to decrease the risk of a positive surgical margin, reduce rates of reexcision, and tailor adjuvant therapy. We used a protease-activated fluorescent imaging probe, LUM015, to detect cancer in vivo in a mouse model of soft tissue sarcoma (STS) and ex vivo in a first-in-human phase 1 clinical trial. In mice, intravenous injection of LUM015 labeled tumor cells, and residual fluorescence within the tumor bed predicted local recurrence. In 15 patients with STS or breast cancer, intravenous injection of LUM015 before surgery was well tolerated. Imaging of resected human tissues showed that fluorescence from tumor was significantly higher than fluorescence from normal tissues. LUM015 biodistribution, pharmacokinetic profiles, and metabolism were similar in mouse and human subjects. Tissue concentrations of LUM015 and its metabolites, including fluorescently labeled lysine, demonstrated that LUM015 is selectively distributed to tumors where it is activated by proteases. Experiments in mice with a constitutively active PEGylated fluorescent imaging probe support a model where tumor-selective probe distribution is a determinant of increased fluorescence in cancer. These co-clinical studies suggest that the tumor specificity of protease-activated imaging probes, such as LUM015, is dependent on both biodistribution and enzyme activity. Our first-in-human data support future clinical trials of LUM015 and other protease-sensitive probes

    Minichromosome maintenance protein 6, a proliferation marker superior to Ki-67 and independent predictor of survival in patients with mantle cell lymphoma

    Get PDF
    Minichromosome maintenance protein 6 (MCM6) is one of six proteins of the MCM family which are involved in the initiation of DNA replication and thus represent a marker of proliferating cells. Since the level of cell proliferation is the most valuable predictor of survival in mantle cell lymphoma (MCL), we investigated lymph node biopsy specimens from 70 patients immunohistochemically with a monoclonal antibody against MCM6. The percentage of MCM6 expressing lymphoma cells ranged from 12.0 to 95.6%, with a mean of 61.0%, and was significantly higher than the percentage of Ki-67-positive cells (P<0.0001). Surprisingly, the ratio of MCM6-positive cells to Ki-67-positive cells was higher than in normal stimulated peripheral blood mononuclear cells, indicating a cell early G1-phase arrest in MCL. A high MCM6 expression level of more than 75% positive cells was associated with a significantly shorter overall survival time (16 months) compared to MCL with a low MCM6 expression level of less than 25% (no median reached, P<0.0001). Multivariate analysis revealed MCM6 to be an independent predictor of survival that is superior to the international prognostic factor and the Ki-67 index. Therefore, aside from gene expression profiling, immunohistochemical detection of MCM6 seems to be the most promising marker for predicting the outcome in MCL

    Can Experienced Observers Differentiate between Lipoma and Well-Differentiated Liposarcoma Using Only MRI?

    Get PDF
    Well-differentiated liposarcoma represents a radiographic diagnostic dilemma. To determine the accuracy, interrater reliability, and relationship of stranding, nodularity, and size in the MRI differentiation of lipoma and well-differentiated liposarcoma, MRI scans of 60 patients with large (>5 cm), deep, pathologically proven lipomas or well-differentiated liposarcomas were examined by 10 observers with subspecialty training blinded to diagnosis. Observers indicated whether the amount of stranding, nodularity, and size of each tumor suggested a benign or malignant diagnosis and rendered a diagnosis of lipoma or well-differentiated liposarcoma. The accuracy, reliability, and relationship of stranding, nodularity, and size to diagnosis were calculated for all samples. 69% of reader MRI diagnoses agreed with final pathology diagnosis (95% CI 65–73%). Readers tended to err choosing a diagnosis of liposarcoma, correctly identifying lipomas in 63% of cases (95% CI 58–69%) and liposarcomas in 75% of cases (95% CI 69–80%). Assessment of the relationship of stranding, nodularity, and size to correct diagnosis showed that the presence of each was associated with a decreased likelihood of a lipoma pathological diagnosis (P < 0.01). While the radiographic diagnosis of lipoma or well-differentiated liposarcoma cannot be made with 100% certainty, experienced observers have a 69% chance of rendering a correct diagnosis

    Training femoral neck screw insertion skills to surgical trainees: computer-assisted surgery versus conventional fluoroscopic technique

    Full text link
    BACKGROUND: Femoral neck fractures are among the most common orthopaedic injuries impacting the health care system. Surgical management of such fractures with cannulated screws is a commonly performed procedure. The acquisition of surgical skills necessary to perform this procedure typically involves learning on real patients with fluoroscopic guidance. This study attempts to determine if a novel computer-navigated training model improves the learning of this basic surgical skill. METHODS A multicenter, prospective, randomized, and controlled study was conducted using surgical trainees with no prior experience in surgically managing femoral neck fractures. After a training session, participants underwent a pretest by performing the surgical task (screw placement) on a simulated hip fracture using fluoroscopic guidance. Immediately after, participants were randomized into either undergoing a training session using conventional fluoroscopy or computer-based navigation. Immediate posttest, retention (4 weeks later), and transfer tests were performed. Performance during the tests was determined by radiographic analysis of hardware placement. RESULTS Screw placement by trainees was ultimately equal to the level of an expert surgeon with either training technique. Participants who trained with computer navigation took fewer attempts to position hardware and used less fluoroscopy time than those trained with fluoroscopy. When those trained with fluoroscopy used computer navigation at the transfer test, less fluoroscopy time and dosage was used. The concurrent augmented feedback provided by computer navigation did not affect the learning of this basic surgical skill in surgical novices. No compromise in learning occurred if the surgical novice trained with one type of technology and transferred to using the other. CONCLUSIONS The findings of this study suggest that computer navigation may be safely used to train surgical novices in a basic procedure. This model avoids using both live patients and harmful radiation without a compromise in the acquisition of a 3-dimensional technical skill
    corecore