2,349 research outputs found

    Drosophila TIF-IA is required for ribosome synthesis and cell growth and is regulated by the TOR pathway

    Get PDF
    Synthesis of ribosomal RNA (rRNA) is a key step in ribosome biogenesis and is essential for cell growth. Few studies, however, have investigated rRNA synthesis regulation in vivo in multicellular organisms. Here, we present a genetic analysis of transcription initiation factor IA (TIF-IA), a conserved RNA polymerase I transcription factor. Drosophila melanogaster Tif-IA−/− mutants have reduced levels of rRNA synthesis and sustain a developmental arrest caused by a block in cellular growth. We find that the target of rapamycin (TOR) pathway regulates TIF-IA recruitment to rDNA. Furthermore, we show that the TOR pathway regulates rRNA synthesis in vivo and that TIF-IA overexpression can maintain rRNA transcription when TOR activity is reduced in developing larvae. We propose that TIF-IA acts in vivo as a downstream growth–regulatory target of the TOR pathway. Overexpression of TIF-IA also elevates levels of both 5S RNA and messenger RNAs encoding ribosomal proteins. Stimulation of rRNA synthesis by TIF-IA may therefore provide a feed-forward mechanism to coregulate the levels of other ribosome components

    Membrane geometry with auxiliary variables and quadratic constraints

    Get PDF
    Consider a surface described by a Hamiltonian which depends only on the metric and extrinsic curvature induced on the surface. The metric and the curvature, along with the basis vectors which connect them to the embedding functions defining the surface, are introduced as auxiliary variables by adding appropriate constraints, all of them quadratic. The response of the Hamiltonian to a deformation in each of the variables is examined and the relationship between the multipliers implementing the constraints and the conserved stress tensor of the theory established.Comment: 8 page

    Dynamical density functional theory for interacting Brownian particles: stochastic or deterministic?

    Get PDF
    We aim to clarify confusions in the literature as to whether or not dynamical density functional theories for the one-body density of a classical Brownian fluid should contain a stochastic noise term. We point out that a stochastic as well as a deterministic equation of motion for the density distribution can be justified, depending on how the fluid one-body density is defined -- i.e. whether it is an ensemble averaged density distribution or a spatially and/or temporally coarse grained density distribution.Comment: 10 pages, 1 figure, to be submitted to Journal of Physics A: Mathematical and Genera

    The density functional theory of classical fluids revisited

    Full text link
    We reconsider the density functional theory of nonuniform classical fluids from the point of view of convex analysis. From the observation that the logarithm of the grand-partition function logΞ[ϕ]\log \Xi [\phi] is a convex functional of the external potential ϕ\phi it is shown that the Kohn-Sham free energy A[ρ]{\cal A}[\rho] is a convex functional of the density ρ\rho. logΞ[ϕ]\log \Xi [\phi] and A[ρ]{\cal A}[\rho] constitute a pair of Legendre transforms and each of these functionals can therefore be obtained as the solution of a variational principle. The convexity ensures the unicity of the solution in both cases. The variational principle which gives logΞ[ϕ]\log \Xi [\phi] as the maximum of a functional of ρ\rho is precisely that considered in the density functional theory while the dual principle, which gives A[ρ]{\cal A}[\rho] as the maximum of a functional of ϕ\phi seems to be a new result.Comment: 10 page

    In Situ Surface Voltage Measurements of Dielectrics Under Electron Beam Irradiation

    Get PDF
    New instrumentation has been developed for non-contact, in vacuo measurements of the electron beam-induced surface voltage as a function of time and position for non-conductive spacecraft materials in a simulated space environment. Used in conjunction with the capabilities of an existing ultrahigh vacuum electron emission analysis chamber, the new instrumentation facilitates measurements of charge accumulation, bulk resistivity, effects of charge depletion and accumulation on yield measurements, electron induced electrostatic breakdown potentials, radiation induced conductivity effects, and the radial dispersion of surface voltage. The novel system uses two movable capacitive sensor electrodes that can be swept across the sample to measure surface charge distributions on samples, using a non-contact method that does not dissipate sample charge. Design details, calibration and characterization measurements of the system are presented, for a surface voltage range from30 kV, voltage resolution \u3c1 \u3eV, and spatial resolutio

    Correlation functions in ionic liquid at coexistence with ionic crystal. Results of the Brazovskii-type field theory

    Full text link
    Correlation functions in the restricted primitive model are calculated within a field-theoretic approach in the one-loop self-consistent Hartree approximation. The correlation functions exhibit damped oscillatory behavior as found before in the Gaussian approximation [Ciach at. al., J. Chem. Phys. {\bf 118}, 3702 (2003)]. The fluctuation contribution leads to a renormalization of both the amplitude and the decay length of the correlation functions. The renormalized quantities show qualitatively different behavior than their mean-field (MF) counterparts. While the amplitude and the decay length both diverge in MF when the λ\lambda-line is approached, the renormalized quantities remain of order of unity in the same dimensionless units down to the coexistence with the ionic crystal. Along the line of the phase transition the decay length and the period of oscillations are independent of density, and their values in units of the diameter of the ions are α011\alpha_0^{-1}\approx 1 and 2π/α12.82\pi/\alpha_1\approx 2.8 respectively.Comment: 21 pages including 9 figure

    Electron Beam Induced Luminescence of SiO2 Optical Coatings

    Get PDF
    Optical coatings of disordered thin film SiO2/SiOx dielectric samples on reflective metal substrates exhibited cathodoluminescence under electron beam irradiation. Measurements of the absolute radiance and emission spectra as functions of incident electron energy, flux and power over a range of sample temperatures are reported. Radiance reached a saturation plateau at high incident electron power. Well below saturation radiance scaled with deposited power, that is linearly with incident power for lower-energy non-penetrating electrons and decreasing with increasing energy for penetrating radiation. Four bands were observed in spectral measurements from 300 nm to 1000 nm. Changes in peak intensity and shifts in peak energies as functions of temperature are described. The observations are explained in terms of a simple disordered band theory model and the transitions that take place between electrons in extended conduction states and localized trapped states associated with structural or compositional defects in the highly disordered insulating materials; this provides a fundamental basis for understanding the dependence of cathodoluminescence on irradiation time, incident flux and energy, and sample thickness and temperature

    Point-of-care versus central testing of hemoglobin during large volume blood transfusion.

    Get PDF
    BACKGROUND: Point-of-care (POC) hemoglobin testing has the potential to revolutionize massive transfusion strategies. No prior studies have compared POC and central laboratory testing of hemoglobin in patients undergoing massive transfusions. METHODS: We retrospectively compared the results of our point-of-care hemoglobin test (EPOC®) to our core laboratory complete blood count (CBC) hemoglobin test (Sysmex XE-5000™) in patients undergoing massive transfusion protocols (MTP) for hemorrhage. One hundred seventy paired samples from 90 patients for whom MTP was activated were collected at a single, tertiary care hospital between 10/2011 and 10/2017. Patients had both an EPOC® and CBC hemoglobin performed within 30 min of each other during the MTP. We assessed the accuracy of EPOC® hemoglobin testing using two variables: interchangeability and clinically significant differences from the CBC. The Clinical Laboratory Improvement Amendments (CLIA) proficiency testing criteria defined interchangeability for measurements. Clinically significant differences between the tests were defined by an expert panel. We examined whether these relationships changed as a function of the hemoglobin measured by the EPOC® and specific patient characteristics. RESULTS: Fifty one percent (86 of 170) of paired samples\u27 hemoglobin results had an absolute difference of ≤7 and 73% (124 of 170) fell within ±1 g/dL of each other. The mean difference between EPOC® and CBC hemoglobin had a bias of - 0.268 g/dL (p = 0.002). When the EPOC® hemoglobin was \u3c 7 g/dL, 30% of the hemoglobin values were within ±7, and 57% were within ±1 g/dL. When the measured EPOC® hemoglobin was ≥7 g/dL, 55% of the EPOC® and CBC hemoglobin values were within ±7, and 76% were within ±1 g/dL. EPOC® and CBC hemoglobin values that were within ±1 g/dL varied by patient population: 77% for cardiac surgery, 58% for general surgery, and 72% for non-surgical patients. CONCLUSIONS: The EPOC® device had minor negative bias, was not interchangeable with the CBC hemoglobin, and was less reliable when the EPOC® value was \u3c 7 g/dL. Clinicians must consider speed versus accuracy, and should check a CBC within 30 min as confirmation when the EPOC® hemoglobin is \u3c 7 g/dL until further prospective trials are performed in this population

    Helfrich-Canham bending energy as a constrained non-linear sigma model

    Full text link
    The Helfrich-Canham bending energy is identified with a non-linear sigma model for a unit vector. The identification, however, is dependent on one additional constraint: that the unit vector be constrained to lie orthogonal to the surface. The presence of this constraint adds a source to the divergence of the stress tensor for this vector so that it is not conserved. The stress tensor which is conserved is identified and its conservation shown to reproduce the correct shape equation.Comment: 5 page
    corecore