49 research outputs found

    Deep Learning Convolutional Neural Network Reconstruction and Radial k-Space Acquisition MR Technique for Enhanced Detection of Retropatellar Cartilage Lesions of the Knee Joint

    Full text link
    OBJECTIVES To assess diagnostic performance of standard radial k-space (PROPELLER) MRI sequences and compare with accelerated acquisitions combined with a deep learning-based convolutional neural network (DL-CNN) reconstruction for evaluation of the knee joint. METHODS Thirty-five patients undergoing MR imaging of the knee at 1.5 T were prospectively included. Two readers evaluated image quality and diagnostic confidence of standard and DL-CNN accelerated PROPELLER MR sequences using a four-point Likert scale. Pathological findings of bone, cartilage, cruciate and collateral ligaments, menisci, and joint space were analyzed. Inter-reader agreement (IRA) for image quality and diagnostic confidence was assessed using intraclass coefficients (ICC). Cohen's Kappa method was used for evaluation of IRA and consensus between sequences in assessing different structures. In addition, image quality was quantitatively evaluated by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements. RESULTS Mean acquisition time of standard vs. DL-CNN sequences was 10 min 3 s vs. 4 min 45 s. DL-CNN sequences showed significantly superior image quality and diagnostic confidence compared to standard MR sequences. There was moderate and good IRA for assessment of image quality in standard and DL-CNN sequences with ICC of 0.524 and 0.830, respectively. Pathological findings of the knee joint could be equally well detected in both sequences (Îş-value of 0.8). Retropatellar cartilage could be significantly better assessed on DL-CNN sequences. SNR and CNR was significantly higher for DL-CNN sequences (both p < 0.05). CONCLUSIONS In MR imaging of the knee, DL-CNN sequences showed significantly higher image quality and diagnostic confidence compared to standard PROPELLER sequences, while reducing acquisition time substantially. Both sequences perform comparably in the detection of knee-joint pathologies, while DL-CNN sequences are superior for evaluation of retropatellar cartilage lesions

    Application of deep learning-based image reconstruction in MR imaging of the shoulder joint to improve image quality and reduce scan time

    Full text link
    OBJECTIVES To compare the image quality and diagnostic performance of conventional motion-corrected periodically rotated overlapping parallel line with enhanced reconstruction (PROPELLER) MRI sequences with post-processed PROPELLER MRI sequences using deep learning-based (DL) reconstructions. METHODS In this prospective study of 30 patients, conventional (19 min 18 s) and accelerated MRI sequences (7 min 16 s) using the PROPELLER technique were acquired. Accelerated sequences were post-processed using DL. The image quality and diagnostic confidence were qualitatively assessed by 2 readers using a 5-point Likert scale. Analysis of the pathological findings of cartilage, rotator cuff tendons and muscles, glenoid labrum and subacromial bursa was performed. Inter-reader agreement was calculated using Cohen's kappa statistic. Quantitative evaluation of image quality was measured using the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). RESULTS Mean image quality and diagnostic confidence in evaluation of all shoulder structures were higher in DL sequences (p value = 0.01). Inter-reader agreement ranged between kappa values of 0.155 (assessment of the bursa) and 0.947 (assessment of the rotator cuff muscles). In 17 cases, thickening of the subacromial bursa of more than 2 mm was only visible in DL sequences. The pathologies of the other structures could be properly evaluated by conventional and DL sequences. Mean SNR (p value = 0.01) and CNR (p value = 0.02) were significantly higher for DL sequences. CONCLUSIONS The accelerated PROPELLER sequences with DL post-processing showed superior image quality and higher diagnostic confidence compared to the conventional PROPELLER sequences. Subacromial bursa can be thoroughly assessed in DL sequences, while the other structures of the shoulder joint can be assessed in conventional and DL sequences with a good agreement between sequences. KEY POINTS • MRI of the shoulder requires long scan times and can be hampered by motion artifacts. • Deep learning-based convolutional neural networks are used to reduce image noise and scan time while maintaining optimal image quality. The radial k-space acquisition technique (PROPELLER) can reduce the scan time and has potential to reduce motion artifacts. • DL sequences show a higher diagnostic confidence than conventional sequences and therefore are preferred for assessment of the subacromial bursa, while conventional and DL sequences show comparable performance in the evaluation of the shoulder joint

    Diagnostic value of T1_{1}- and T2_{2}-weighted 3-Tesla MRI for postmortem detection and age stage classification of myocardial infarction

    Full text link
    The aims of this study are to retrospectively evaluate the diagnostic value of T1_{1}- and T2_{2}-weighted 3-T magnetic resonance imaging (MRI) for postmortem detection of myocardial infarction (MI) in terms of sensitivity and specificity and to compare the MRI appearance of the infarct area with age stages. Postmortem MRI examinations (n = 88) were retrospectively reviewed for the presence or absence of MI by two raters blinded to the autopsy results. The sensitivity and specificity were calculated using the autopsy results as the gold standard. A third rater, who was not blinded to the autopsy findings, reviewed all cases in which MI was detected at autopsy for MRI appearance (hypointensity, isointensity, hyperintensity) of the infarct area and the surrounding zone. Age stages (peracute, acute, subacute, chronic) were assigned based on the literature and compared with the age stages reported in the autopsy reports. The interrater reliability between the two raters was substantial (κ = 0.78). Sensitivity was 52.94% (both raters). Specificity was 85.19% and 92.59%. In 34 decedents, autopsy identified an MI (peracute: n = 7, acute: n = 25, chronic: n = 2). Of 25 MI classified as acute at autopsy, MRI classified peracute in four cases and subacute in nine cases. In two cases, MRI suggested peracute MI, which was not detected at autopsy. MRI could help to classify the age stage and may indicate the area for sampling for further microscopic examination. However, the low sensitivity requires further additional MRI techniques to increase the diagnostic value

    Added value of ultra-short echo time and fast field echo using restricted echo-spacing MR imaging in the assessment of the osseous cervical spine

    Full text link
    PURPOSE To evaluate the added value of ultra-short echo time (UTE) and fast field echo resembling a CT using restricted echo-spacing (FRACTURE) MR sequences in the assessment of the osseous cervical spine using CT as reference. MATERIALS AND METHODS Twenty-seven subjects underwent postmortem CT and MRI within 48 h. Datasets were anonymized and analyzed retrospectively by two radiologists. Morphological cervical spine alterations were rated on CT, UTE and FRACTURE images. Afterward, neural foraminal stenosis was graded on standard MR and again after viewing additional UTE/FRACTURE sequences. To evaluate interreader and intermodality reliability, intra-class correlation coefficients (ICC) and for stenosis grading Wilcoxon-matched-pairs testing with multiple comparison correction were calculated. RESULTS Moderate interreader reliability (ICC = 0.48-0.71) was observed concerning morphological findings on all modalities. Intermodality reliability was good between modalities regarding degenerative vertebral and joint alterations (ICC = 0.69-0.91). Compared to CT neural stenosis grades were more often considered as nonsignificant on all analyzed MR sequences. Neural stenosis grading scores differed also significantly between specific bone imaging sequences, UTE and FRACTURE, to standard MR sequences. However, no significant difference was observed between UTE and FRACTURE sequences. CONCLUSION Compared to CT as reference, UTE or FRACTURE sequence added to standard MR sequences can deliver comparable information on osseous cervical spine status. Both led to changes in clinically significant stenosis gradings when added to standard MR, mainly reducing the severity of neural foramina stenosis

    Simultaneous intra/extravascular administration of antiproliferative agents as a new strategy to inhibit restenosis: The peak of reactive cell proliferation as a hallmark for the duration of the treatment

    Get PDF
    BACKGROUND: Strictly intravascular approaches for the treatment of postangioplasty restenosis are effective in the intima and the inner parts of the media but may be insufficient to control redundant pathways in the more outer parts of the media and the adventitia. An inverse situation may occur subsequently to a strictly extravascular approach, like the recently suggested pericardial approach in pigs. We hypothesized that simultaneous intra/extravascular administration of anti-restenotic agents inhibits restenosis by blocking all stimulatory pathways in the entire arterial wall. METHODS: Fresh hearts of 25 domestic pigs were obtained from a local slaughterhouse. Left anterior descending coronary arteries (LAD) were harvested, cut into cylindric 5 mm segments, and cultured as ex vivo porcine organ cultures (POCs). After 9 bar ballooning simultaneous intra/extravascular administration of high dose diltiazem (50 μg/mL) was carried out for a period of 1, 2, 3, 4, 5, 6, and 7 days. At day 7 and 28 proliferative activity (BrdU), neointimal thickening, and staining against smooth muscle α-actin and vWF was analysed. RESULTS: 7 days after ballooning administration of diltiazem for 4, 5, 6, and 7 days inhibited reactive cell proliferation by more than 50% (n.s.) as compared to control, 28 days after ballooning administration for 6 and 7 days inhibited neointimal thickening by more than 75% (p < 0.05). Simultaneous intra/extravascular administration of high dose diltiazem did not affect the expression of vWF in endothelial cells or smooth muscle α-actin in smooth muscle cells. CONCLUSIONS: Simultaneous intra/extravascular administration of high dose diltiazem (50 μg/mL) has to be maintained for at least 6 days to achieve a significant inhibition of neointimal thickening. The data demonstrate the importance of the maximal reactive cell proliferation (= day 7 in the POC-model) for the calculation of the duration of the treatment period

    Institutional Environments for Enabling Agricultural Technology Innovations: The Role of Land Rights in Ethiopia, Ghana, India and Bangladesh

    Full text link

    Social Safety Nets for Food and Nutritional Security in India

    Full text link
    This paper brings together existing literature on the Mahatma Gandhi National Rural Employment Guarantee Act (MGNRGEA) and the Public Distribution System (PDS) in India, offering a narrative review of the evidence on impacts on food security, health and nutrition of beneficiaries. Both programs operate on a large scale and have the capacity to impact the factors leading to undernutrition. It is evident that despite the deficiencies in implementation, both the MGNREGA and the PDS are inclusive and reach the poor and the marginalized who are likely to also experience greater undernutrition and poor health. Data challenges have however prevented researchers from conducting studies that assess the ultimate impact of these two large-scale programs on health and nutrition. The evidence that exists suggests largely positive impacts indicating a clear potential to make these programs more nutrition sensitive not just by incorporating elements that would explicitly address nutritional concerns but also by directing specific attention to innovations that strengthen critical complementarities and synergies that exist between the two programs

    Postmortem magnetic resonance imaging and postmortem computed tomography in ligature and manual strangulation

    Full text link
    PURPOSE:The aim of this study was to evaluate magnetic resonance imaging (MRI) findings in cases of fatal manual or ligature strangulation. Verification of strangulation by computed tomography (CT), MRI, and at autopsy as well as its detectability in each modality was assessed. METHODS:We retrospectively analyzed 6 manual and ligature strangulation cases between 2013 and 2019 who all underwent a whole-body CT, head and neck MRI, and an autopsy. Two radiologists examined head and neck imaging data and compared the data to autopsy findings. RESULTS:Magnetic resonance imaging showed a high efficiency in verifying intramuscular hemorrhages, which were confirmed in autopsy. Moreover, in one case without a visible strangulation mark, soft tissue injuries associated with strangulation were detected. Fractures, especially thyroid cartilage fractures, were successfully diagnosed by CT. CONCLUSIONS:As MRI showed a successful detection of soft tissue lesions in relation to strangulation, it can serve as an alternative method or provide additional value to an autopsy. Intramuscular hemorrhages are a common finding in manual and ligature strangulation, providing a useful sign of applied pressure on the neck. However, to evaluate fractures, an additional CT or autopsy is recommended

    7-T MRI for brain virtual autopsy: a proof of concept in comparison to 3-T MRI and CT

    Get PDF
    The detection and assessment of cerebral lesions and traumatic brain injuries are of particular interest in forensic investigations in order to differentiate between natural and traumatic deaths and to reconstruct the course of events in case of traumatic deaths. For this purpose, computed tomography (CT) and magnetic resonance imaging (MRI) are applied to supplement autopsy (traumatic death) or to supplant autopsy (natural deaths). This approach is termed “virtual autopsy.” The value of this approach increases as more microlesions and traumatic brain injuries are detected and assessed. Focusing on these findings, this article describes the examination of two decedents using CT, 3-T, and 7-T MRI. The main question asked was whether there is a benefit in using 7-T over 3-T MRI. To answer this question, the 3-T and 7-T images were graded regarding the detectability and the assessability of coup/contrecoup injuries and microlesions using 3-point Likert scales. While CT missed these findings, they were detectable on 3-T and 7-T MRI. However, the 3-T images appeared blurry in direct comparison with the 7-T images; thus, the detectability and assessability of small findings were hampered on 3-T MRI. The potential benefit of 7-T over 3-T MRI is discussed

    Evaluation of ultrashort echo-time (UTE) and fast-field-echo (FRACTURE) sequences for skull bone visualization and fracture detection - A postmortem study

    Get PDF
    BACKGROUND AND PURPOSE CT is considered the modality of choice in the assessment of the skull due to the fast and accurate depiction of bone structures. Nevertheless, MRI has evolved into a possible alternative due to optimal soft tissue contrast and recent advances with the ability to visualize tissues with shortest T2 times, such as osseous structures. In this study we compare skull bone visualization and fracture detection across two MRI sequences to CT as reference standard. MATERIAL AND METHODS Twenty subjects underwent CT and MRI with less than 72 h between examination. The MRI protocol included a 2D ultrashort echo time (UTE) and a 3D multi-echo in-phase fast-field-echo (FRACTURE) sequence. Independent raters evaluated qualitative characteristics and fracture detectability in different skull subregions (skull vault, skull base and viscerocranium). Interrater and intermodality agreement was evaluated by calculating intraclass coefficients (ICC). RESULTS FRACTURE ICC indicated a good agreement in all subregions (ICC = 0.83 - 0.88), whereas UTE had excellent results calculated in the skull vault and viscerocranium (ICC = 0.91 - 0.94). At the skull vault, both MRI sequences received an overall good rating (UTE: 2.63 ± 0.42 FRACTURE. 2.81 ± 0.32). Fracture detection using MRI sequences for the skull vault, was highest compared to other subregions. CONCLUSIONS Both MRI sequences may provide an alternative e.g. for surgical planning or follow up exams of the osseous neurocranium; although, at the skull base and viscerocranium bone visualization with MRI bone imaging sequences perform inferior to CT standard imaging
    corecore