3 research outputs found

    Guidelines for performing skin tests with drugs in the investigation of cutaneous adverse drug reactions

    Get PDF
    Skin testing with a suspected drug has been reported to be helpful in determining the cause of cutaneous adverse drug reactions (CADR). Many isolated reports of positive drug skin tests are published, but without detailed information concerning the clinical features of the CADR and the method used in performing drug skin tests, such data are not very informative. A working party of the European Society of Contact Dermatitis (ESCD) for the study of skin testing in investigating cutaneous adverse drug reactions, has proposed the herein-reported guidelines for performing skin testing in CADR in order to standardize these procedures. In each reported case, the imputability of each drug taken at the onset of the CADR and a highly detailed description and characterization of the dermatitis need to be given. Drug skin tests are performed 6 weeks to 6 months after complete healing of the CADR. Drug patch tests are performed according to the methods used in patch testing in studying contact dermatitis. The commercialized form of the drug used by the patient is tested diluted at 30% pet. (pet.) and/or water (aq.). The pure drug is tested diluted at 10% in pet. or aq. In severe CADR, drug patch tests are performed at lower concentrations. It is also of value to test on the most affected site of the initial CADR. Drug prick tests are performed on the volar forearm skin with the commercialized form of the drug, but with sequential dilutions in cases of urticaria. Intradermal tests (IDT) are performed with sterile sequential dilutions (10-4, 10-3, 10-2, 10-1) of a pure sterile or an injectable form of the suspected drug with a small volume of 0.04 ml. Drug skin tests need to be read at 20 min and also later at D2 and D4 for patch tests, at D1 for prick tests and IDT. All these tests also need to be read at 1 week. The success of skin tests varies with the drug tested, with a high % of positive results, for example, with betalactam antibiotics, pristinamycin, carbamazepine and tetrazepam on patch testing, or with betalactam antibiotics and heparins on delayed readings of IDT. The results of drug skin tests also depend on the clinical features of the CADR. The use of appropriate control patients is necessary to avoid false-positive results

    Position statement: The need for EU legislation to require disclosure and labelling of the composition of medical devices

    No full text
    BACKGROUND: In recent years, skin reactions secondary to the use of medical devices (MD), such as allergic contact dermatitis have increasingly been observed (e.g. to continuous blood sugar monitoring systems, insulin pumps, wound dressings, medical gloves, etc.): this is regarded as a developing epidemic. Lack of labelling of the composition of MD, as well as frequent lack of cooperation of manufacturers to disclose this relevant information, even when contacted by the clinician for the individual case of an established adverse reaction, significantly impede patient care. OBJECTIVES: To advocate for full ingredient labelling in the implementation of EU regulation for MD. METHODS: This position paper reviews the scientific literature, the current regulatory framework adopted for MD to date, and the likely impact, including some costs data in case of the absence of such labelling. RESULTS: Efforts made by several scientific teams, who are trying to identify the culprit of such adverse effects, either via asking for cooperation from companies, or using costly chemical analyses of MD, can only partly, and with considerable delay, compensate for the absence of meaningful information on the composition of MD; hence, patient management is compromised. Indeed, without knowing the chemical substances present, physicians are unable to inform patients about which substances they should avoid, and which alternative MD may be suitable/tolerated. CONCLUSION: There is an urgent need for full and accurate labelling of the chemical composition of MD in contact with the human body

    The European baseline series: Criteria for allergen inclusion (with reference to formaldehyde releasers)

    No full text
    Data de publicació electrònica: 21-03-2021Existing criteria for inclusion in the European baseline series are summarized. Additional criteria are developed to aid decision making where the current criteria do not yield an unequivocal result. These include a consideration of whether an allergen (hapten) is better placed in a special series and the frequency with which an allergen cross-reacts with existing markers in the baseline series
    corecore