485 research outputs found

    Translation and validation of the Korean confusion assessment method for the intensive care unit

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Delirium is a common problem and associated with poor outcomes in intensive care unit (ICU) patients. Diagnosis of delirium in ICU patients is limited and usually underdiagnosed by physicians. The Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) is one of the most widely used screening methods for detection of ICU delirium. Our goal was to translate and validate the CAM-ICU for use in the Korean ICU setting.</p> <p>Methods</p> <p>Translation of the CAM-ICU was done according to the guidelines suggested by the Translation and Cultural Adaptation Group. For validation and interrater reliability assessment of the Korean CAM-ICU, two nurses independently assessed delirium in ICU patients and the results were compared with the reference evaluation, which was done by a psychiatrist using the Diagnostic and Statistical Manual of Mental Disorders IV (DSM-IV).</p> <p>Results</p> <p>Twenty-two patients were evaluated by two nurses and one psychiatrist expert independently. During the study period, we have continuously educated study nurses. Based on DSM-IV criteria, 16 out of 22 (72.7%) patients developed delirium. The sensitivities of the two nurses' evaluations using the Korean CAM-ICU were 89.80% for nurse 1 and 77.40% for nurse 2. Their specificities were 72.40% and 75.80% and their overall accuracy was 83.33% and 88.37% respectively. The Korean CAM-ICU was done with reasonable interrater reliability between nurse 1 and nurse 2 (κ = 0.81, <it>p </it>< 0.001).</p> <p>Conclusions</p> <p>The Korean CAM-ICU showed good validity and could be incorporated into clinical practice in Korean ICUs.</p> <p>Trial registration</p> <p>ISRCTN: <a href="http://www.controlled-trials.com/ISRCTN50265663">ISRCTN50265663</a></p

    Separation of Electrolytic Reduction Product from Stainless Steel Wire Mesh Cathode Basket via Salt Draining and Reuse of the Cathode Basket

    Get PDF
    We demonstrated that the metallic product obtained after electrolytic reduction (also called oxide reduction (OR)) can be simply separated from a stainless steel wire mesh cathode basket only by using a salt drain. First, the OR run of a simulated oxide fuel (0.6 kg/batch) was conducted in a molten Li2O–LiCl salt electrolyte at 650°C. The simulated oxide fuel of the porous cylindrical pellets was used as a cathode by loading a stainless steel wire mesh cathode basket. Platinum was employed as an anode. After the electrolysis, the residual salt of the cathode basket containing the reduction product was drained by placing it at gas phase above the molten salt using a holder. Then, at a room temperature, the complete separation of the reduction product from the cathode basket was achieved by inverting it without damaging or deforming the basket. Finally, the emptied cathode basket obtained after the separation was reused for the second OR run by loading a fresh simulated oxide fuel. We also succeeded in the separation of the metallic product from the reused cathode basket for the second OR run

    Quantitative Analysis of Oxygen Gas Exhausted from Anode through In Situ Measurement during Electrolytic Reduction

    Get PDF
    Quantitative analysis by in situ measurement of oxygen gas evolved from an anode was employed to monitor the progress of electrolytic reduction of simulated oxide fuel in a molten Li2O–LiCl salt. The electrolytic reduction of 0.6 kg of simulated oxide fuel was performed in 5 kg of 1.5 wt.% Li2O–LiCl molten salt at 650°C. Porous cylindrical pellets of simulated oxide fuel were used as the cathode by loading a stainless steel wire mesh cathode basket. A platinum plate was employed as the anode. The oxygen gas evolved from the anode was exhausted to the instrumentation for in situ measurement during electrolytic reduction. The instrumentation consisted of a mass flow controller, pump, wet gas meter, and oxygen gas sensor. The oxygen gas was successfully measured using the instrumentation in real time. The measured volume of the oxygen gas was comparable to the theoretically calculated volume generated by the charge applied to the simulated oxide fuel

    Electrical conductivity enhancement of epitaxially grown TiN thin films

    Full text link
    Titanium nitride (TiN) presents superior electrical conductivity with mechanical and chemical stability and compatibility with the semiconductor fabrication process. Here, we fabricated epitaxial and polycrystalline TiN (111) thin films on MgO (111), sapphire (001), and mica substrates at 640oC and room temperature by using a DC sputtering, respectively. The epitaxial films show less amount of surface oxidation than the polycrystalline ones grown at room temperature. The epitaxial films show drastically reduced resistivity (~30 micro-ohm-cm), much smaller than the polycrystalline films. Temperature-dependent resistivity measurements show a nearly monotonic temperature slope down to low temperature. These results demonstrate that high temperature growth of TiN thin films leads to significant enhancement of electrical conductivity, promising for durable and scalable electrode applications.Comment: 14 pages, 3 figure

    Fabrication and evaluation of bilateral Helmholtz radiofrequency coil for thermo-stable breast image with reduced artifacts

    Get PDF
    PURPOSE: The positron emission tomography (PET)-magnetic resonance (MR) system is a newly emerging technique that yields hybrid images with high-resolution anatomical and metabolic information. With PET-MR imaging, a definitive diagnosis of breast abnormalities will be possible with high spatial accuracy and images will be acquired for the optimal fusion of anatomic locations. Therefore, we propose a PET-compatible two-channel breast MR coil with minimal disturbance to image acquisition which can be used for simultaneous PET-MR imaging in patients with breast cancer. MATERIALS AND METHODS: For coil design and construction, the conductor loops of the Helmholtz coil were tuned, matched, and subdivided with nonmagnetic components. Element values were optimized with an electromagnetic field simulation. Images were acquired on a GE 600 PET-computed tomography (CT) and GE 3.0 T MR system. For this study, we used the T1-weighted image (volunteer; repetition time (TR), 694 ms; echo time (TE), 9.6 ms) and T2-weighted image (phantom; TR, 8742 ms; TE, 104 ms) with the fast spin-echo sequence. RESULTS: The results of measuring image factors with the proposed radiofrequency (RF) coil and standard conventional RF coil were as follows: signal-to-noise ratio (breast; 207.7 vs. 175.2), percent image uniformity (phantom; 89.22%-91.27% vs. 94.63%-94.77%), and Hounsfield units (phantom; -4.51 vs. 2.38). CONCLUSIONS: Our study focused on the feasibility of proposed two-channel Helmholtz loops (by minimizing metallic components and soldering) for PET-MR imaging and found the comparable image quality to the standard conventional coil. We believe our work will help significantly to improve image quality with the development of a less metallic breast MR coil

    Proteomics-based dissection of biotic stress responsive proteins in bread wheat (Triticum aestivum L.)

    Get PDF
    Proteomic techniques that allow the identification and quantification of stress-related proteins, mapping dynamics of their expression and post translational modifications represent an important approach in the research of plant stresses. Biotic stress is one of the major stresses limiting crop productivity and the geographical distribution of many important crops worldwide. Two hundred and seventeen protein spots reproducibly were detected from six gels by using two-dimensional electrophoresis. After tryptic digestion, MALDI-TOF/MS analysis and database searching of some of the identified proteins indicated that the proteins are known to be involved in several biotic stress related functions as disease associate with pathogens. Mass spectrometry analysis allowed the identification of 185 differential expressed proteins with isoforms including well known biotic stress  esponsive proteins. Keumgang (13%), Jinpum (8%), China-108 (14%), Yeonnon-67 (11%), Norin-61 (22%) and Kantou-107 (32%) were identified as biotic stress responses proteins directly coupled to disease and pathogen infection on wheat. Nevertheless, our studies provides new insights into identification of biotic stress responses protein in disease infected wheat grain by natural condition, the post-translational modification in  protein sequences, verify eventual differences among the genotypes in relation to them, and demonstrates the advantages of proteomic analysis.Key words: Biotic stress, matrix-assisted laser desorption ionization-time of flight, proteomics, posttranslational modification, two-dimensional electrophoresis, wheat

    The Effectiveness of Short Message Service to Assure the Preparation-to-Colonoscopy Interval before Bowel Preparation for Colonoscopy

    Get PDF
    Background/Aims. The preparation-to-colonoscopy (PC) interval is one of several important factors for the bowel preparation. Short message service (SMS) reminder from a cellular phone has been suggested to improve compliance in various medical situations. We evaluated the effectiveness of SMS reminders to assure the PC interval for colonoscopy. Methodology. This prospective randomized study was investigator blinded. In the No-SMS group, patients took the first 2 L polyethylene glycol (PEG) between 6 and 8 PM on the day before colonoscopy and the second 2 L PEG approximately 6 hours before the colonoscopy without SMS. In the SMS group, patients took first 2 L PEG in the same manner as the No-SMS group and the second 2 L PEG after receiving an SMS 6 hours before the colonoscopy. Results. The SMS group had a lower score than the No-SMS group, according to the Ottawa Bowel Preparation Scale (P<0.001). Multivariate logistic regression analysis showed that compliance with diet instructions (odds ratio (OR) 2.109; 95% confidence interval (CI), 1.11–3.99, P=0.022) and intervention using SMS ((OR) 2.329; 95% (CI), 1.34–4.02, P=0.002) were the independent significant factors for satisfactory bowel preparation. Conclusions. An SMS reminder to assure PC interval improved the bowel preparation quality for colonoscopy with bowel preparation

    A Case of Superficial Giant Basal Cell Carcinoma with Satellite Lesions on Scalp

    Get PDF
    Giant basal cell carcinoma (BCC), defined as a lesion greater than 5 cm at its largest diameter, is a rare variant of BCC. In contrast to small BCC, giant BCC develops on skin that is not exposed to sunlight, including the back, shoulder, groin and thigh. Most of the histopathologic subtypes of giant BCC are micronodular, morpheaform and nodular, but the superficial subtype is rare. Giant superficial BCC arising on the scalp is extremely rare. We report the case of giant superficial BCC with four satellite lesions on the scalp in a 53-year-old male without predisposing factors

    Active pulmonary tuberculosis and latent tuberculosis infection among homeless people in Seoul, South Korea: a cross-sectional study

    Get PDF
    Background : The aim of this study was to determine the prevalence rate of latent TB infection (LTBI) and active TB among homeless in Seoul metropolitan city, South Korea, and to compare the TB burden among homeless people with that of a control group. Methods : The homeless participants were recruited from five sites between October 30, 2009 and April 12, 2010. LTBI was diagnosed through the QuantiFERON(R) TB Gold In-Tube(QFT-GIT) assay and a tuberculin skin test(TST) and, and active PTB was diagnosed based on chest radiography. Results : Among 313 participants, the prevalence of LTBI was 75.9% (95% CI, 71.1-80.8%) and 79.8% (95% CI, 74.9-84.7%) based on a QFT-GIT assay and the TST, respectively, and that of active PTB was 5.8% (95% CI, 3.2-8.3%). The prevalence of LTBI among homeless participants was about five times higher than controls. Also, the age-specific prevalence rate ratio of active PTB was as high as 24.86. Conclusions : The prevalence rate of LTBI as well as active PTB among homeless people was much higher than that of the general population in South Korea. Thus, adequate strategies to reduce the TB burden among homeless people are needed.Peer Reviewe
    corecore