CAIPIRINHA-accelerated 10-min 3D TSE MRI of the ankle for the diagnosis of painful ankle conditions: Performance evaluation in 70 patients
OBJECTIVES To test the hypothesis that MRI of the ankle with a 10-min 3D CAIPIRINHA SPACE TSE protocol is at least equivalent for the detection of painful conditions when compared to a 20-min 2D TSE standard of reference protocol.
METHODS Following institutional review board approval and informed consent, 70 symptomatic subjects underwent 3T MRI of the ankle. Six axial, sagittal and coronal intermediate-weighted (IW) and fat-saturated T2-weighted (T2FS) 2D TSE (total acquisition time, 20 min), and two sagittal isotropic IW and T2FS 3D CAIPIRINHA TSE (10 min) pulse sequence prototypes were obtained. Following randomization and anonymization, two musculoskeletal radiologists evaluated the 2D and 3D datasets independently. Descriptive statistics, inter-reader reliability, inter-method concordance, diagnostic definitiveness tests were applied. P-values < 0.05 were considered significant.
RESULTS Raters diagnosed 116 cartilage defects with 2D and 109 with 3D MRI, 35 ligament tears with 2D and 65 with 3D MRI, 18 tendon tears with 2D and 20 with 3D MRI, and 137 osseous abnormalities with 2D and 149 with 3D MRI. The inter-reader agreement was high for 2D (Kendall W, 0.925) and 3D MRI (W, 0.936) (p < 0.05), as was the inter-method concordance (W, 0.919). The diagnostic definitiveness of readers was higher for 3D MRI than 2D MRI in 10-27% of the time, while the reverse was true in 7-11% of the time (p < 0.01).
CONCLUSIONS The performance of 10-min 3D CAIPIRINHA SPACE MRI for the detection of painful ankle conditions is similar to that of a 20-min 2D TSE MRI reference standard.
KEY POINTS • CAIPIRINHA Acceleration facilitates isotropic 3D MRI of the Ankle in 10 min. • 10-min 3D CAIPIRINHA MRI and 20-min 2D TSE MRI have similar performance. • 3D CAIPIRINHA SPACE MRI afforded higher diagnostic definitiveness of readers
Recommended from our members
Surveillance of abdominal aortic aneurysm using accelerated 3D non-contrast black-blood cardiovascular magnetic resonance with compressed sensing (CS-DANTE-SPACE).
BACKGROUND:3D non-contrast high-resolution black-blood cardiovascular magnetic resonance (CMR) (DANTE-SPACE) has been used for surveillance of abdominal aortic aneurysm (AAA) and validated against computed tomography (CT) angiography. However, it requires a long scan time of more than 7 min. We sought to develop an accelerated sequence applying compressed sensing (CS-DANTE-SPACE) and validate it in AAA patients undergoing surveillance. METHODS:Thirty-eight AAA patients (all males, 73 ± 6 years) under clinical surveillance were recruited for this study. All patients were scanned with DANTE-SPACE (scan time 7:10 min) and CS-DANTE-SPACE (scan time 4:12 min, a reduction of 41.4%). Nine 9 patients were scanned more than 2 times. In total, 50 pairs of images were available for comparison. Two radiologists independently evaluated the image quality on a 1-4 scale, and measured the maximal diameter of AAA, the intra-luminal thrombus (ILT) and lumen area, ILT-to-muscle signal intensity ratio, and the ILT-to-lumen contrast ratio. The sharpness of the aneurysm inner/outer boundaries was quantified. RESULTS:CS-DANTE-SPACE achieved comparable image quality compared with DANTE-SPACE (3.15 ± 0.67 vs. 3.03 ± 0.64, p = 0.06). There was excellent agreement between results from the two sequences for diameter/area and ILT ratio measurements (ICCs> 0.85), and for quantifying growth rate (3.3 ± 3.1 vs. 3.3 ± 3.4 mm/year, ICC = 0.95.) CS-DANTE-SPACE showed a higher ILT-to-lumen contrast ratio (p = 0.01) and higher sharpness than DANTE-SPACE (p = 0.002). Both sequences had excellent inter-reader reproducibility for quantitative measurements (ICC > 0.88). CONCLUSION:CS-DANTE-SPACE can reduce scan time while maintaining image quality for AAA imaging. It is a promising tool for the surveillance of patients with AAA disease in the clinical setting
Recommended from our members
Surveillance of abdominal aortic aneurysm using accelerated 3D non-contrast black-blood cardiovascular magnetic resonance with compressed sensing (CS-DANTE-SPACE).
Background3D non-contrast high-resolution black-blood cardiovascular magnetic resonance (CMR) (DANTE-SPACE) has been used for surveillance of abdominal aortic aneurysm (AAA) and validated against computed tomography (CT) angiography. However, it requires a long scan time of more than 7 min. We sought to develop an accelerated sequence applying compressed sensing (CS-DANTE-SPACE) and validate it in AAA patients undergoing surveillance.MethodsThirty-eight AAA patients (all males, 73 ± 6 years) under clinical surveillance were recruited for this study. All patients were scanned with DANTE-SPACE (scan time 7:10 min) and CS-DANTE-SPACE (scan time 4:12 min, a reduction of 41.4%). Nine 9 patients were scanned more than 2 times. In total, 50 pairs of images were available for comparison. Two radiologists independently evaluated the image quality on a 1-4 scale, and measured the maximal diameter of AAA, the intra-luminal thrombus (ILT) and lumen area, ILT-to-muscle signal intensity ratio, and the ILT-to-lumen contrast ratio. The sharpness of the aneurysm inner/outer boundaries was quantified.ResultsCS-DANTE-SPACE achieved comparable image quality compared with DANTE-SPACE (3.15 ± 0.67 vs. 3.03 ± 0.64, p = 0.06). There was excellent agreement between results from the two sequences for diameter/area and ILT ratio measurements (ICCs> 0.85), and for quantifying growth rate (3.3 ± 3.1 vs. 3.3 ± 3.4 mm/year, ICC = 0.95.) CS-DANTE-SPACE showed a higher ILT-to-lumen contrast ratio (p = 0.01) and higher sharpness than DANTE-SPACE (p = 0.002). Both sequences had excellent inter-reader reproducibility for quantitative measurements (ICC > 0.88).ConclusionCS-DANTE-SPACE can reduce scan time while maintaining image quality for AAA imaging. It is a promising tool for the surveillance of patients with AAA disease in the clinical setting
Fully Automated 10-Minute 3D CAIPIRINHA SPACE TSE MRI of the Knee in Adults: A Multicenter, Multireader, Multifield-Strength Validation Study
10-Min 3D Turbo Spin Echo MRI of the Knee in Children: Arthroscopy-Validated Accuracy for the Diagnosis of Internal Derangement
BACKGROUND Ten-minute MRI of the pediatric knee can add value through increased cost-effectiveness and decreased sedation needs but requires validation of its clinical efficacy. PURPOSE To determine the arthroscopy-based diagnostic accuracy and interreader reliability of 10-min 3D Controlled Aliasing In Parallel Imaging Results In Higher Acceleration (CAIPIRINHA) turbo spin echo (TSE) MRI with two isotropic pulse sequences for the diagnosis of internal derangement in children with painful knee conditions. STUDY TYPE Prospective. SUBJECTS Sixty children. FIELD STRENGTH/SEQUENCE 3T, gradient echo-based scout with automatic anatomical landmark recognition and plane prescription, 3D CAIPIRINHA SPACE TSE. ASSESSMENT Three fellowship-trained musculoskeletal radiologists evaluated the MRI studies independently and resolved discrepancies through consensus. Outcome variables included image quality, motion artifacts, meniscal abnormalities, anterior and posterior cruciate ligament tears, and cartilage lesions. Arthroscopic surgery served as the standard of reference, which was performed after 37 (range, 1-143) days post-MRI. STATISTICAL TESTS Diagnostic accuracy analysis of MRI with arthroscopic surgery as the standard of reference. Reliability analysis through calculation of interreader agreements with kappa statistics. RESULTS All studies were suitable for diagnostic interpretation with good-to-very-good image quality ratings and little-to-no motion degradation ratings in the majority of cases. The sensitivities/specificities/accuracies of 3D CAIPIRINHA TSE MRI were 0.93/0.96/0.94 for 15/60 (25%) medial meniscal tears, 0.95/0.92/0.94 for 21/60 (35%) lateral meniscal tears, 0.83/1.00/0.92 for 6/60 (17%) discoid menisci, 1.00/0.98/0.99 for 16/60 (27%) anterior cruciate ligament tears, 1.0/1.0/1.0 for 2/60 (3%) posterior cruciate ligament tears, 1.00/1.00/1.00 for 5/60 (8%) osteochondritis dissecans lesions, 0.71/0.96/0.84 for 48 (13%) defects in 360 cartilage segments, and 0.85/0.97/0.91 overall. The interreader agreements were overall good-to-very-good (kappa, 0.72-1.00). DATA CONCLUSION The clinical use of 10-min 3D CAIPIRINHA TSE MRI of the knee in children with painful knee conditions yields an overall high arthroscopy-validated diagnostic accuracy of 91% and good-to-very good interreader reliability for the diagnosis of internal knee derangements. LEVEL OF EVIDENCE 1 Technical Efficacy: Stage 6 J. MAGN. RESON. IMAGING 2018
Recommended from our members
Accelerated whole brain intracranial vessel wall imaging using black blood fast spin echo with compressed sensing (CS-SPACE)
OBJECTIVE:Develop and optimize an accelerated, high-resolution (0.5 mm isotropic) 3D black blood MRI technique to reduce scan time for whole-brain intracranial vessel wall imaging. MATERIALS AND METHODS:A 3D accelerated T1-weighted fast-spin-echo prototype sequence using compressed sensing (CS-SPACE) was developed at 3T. Both the acquisition [echo train length (ETL), under-sampling factor] and reconstruction parameters (regularization parameter, number of iterations) were first optimized in 5 healthy volunteers. Ten patients with a variety of intracranial vascular disease presentations (aneurysm, atherosclerosis, dissection, vasculitis) were imaged with SPACE and optimized CS-SPACE, pre and post Gd contrast. Lumen/wall area, wall-to-lumen contrast ratio (CR), enhancement ratio (ER), sharpness, and qualitative scores (1-4) by two radiologists were recorded. RESULTS:The optimized CS-SPACE protocol has ETL 60, 20% k-space under-sampling, 0.002 regularization factor with 20 iterations. In patient studies, CS-SPACE and conventional SPACE had comparable image scores both pre- (3.35 ± 0.85 vs. 3.54 ± 0.65, p = 0.13) and post-contrast (3.72 ± 0.58 vs. 3.53 ± 0.57, p = 0.15), but the CS-SPACE acquisition was 37% faster (6:48 vs. 10:50). CS-SPACE agreed with SPACE for lumen/wall area, ER measurements and sharpness, but marginally reduced the CR. CONCLUSION:In the evaluation of intracranial vascular disease, CS-SPACE provides a substantial reduction in scan time compared to conventional T1-weighted SPACE while maintaining good image quality