15 research outputs found

    Cross-imaging system comparison of backscatter coefficient estimates from a tissue-mimicking material

    Get PDF
    A key step toward implementing quantitative ultrasound techniques in a clinical setting is demonstrating that parameters such as the ultrasonic backscatter coefficient (BSC) can be accurately estimated independent of the clinical imaging system used. In previous studies, agreement in BSC estimates for well characterized phantoms was demonstrated across different laboratory systems. The goal of this study was to compare the BSC estimates of a tissue mimicking sample measured using four clinical scanners, each providing RF echo data in the 1-15 MHz frequency range. The sample was previously described and characterized with single-element transducer systems. Using a reference phantom for analysis, excellent quantitative agreement was observed across the four array-based imaging systems for BSC estimates. Additionally, the estimates from data acquired with the clinical systems agreed with theoretical predictions and with estimates from laboratory measurements using single-element transducers

    Angle-dependent ultrasonic detection and imaging of two types of brachytherapy seeds using singular spectrum analysis

    No full text
    Brachytherapy to treat prostate cancer uses transrectal ultrasound to guide implantation of titanium-shelled radioactive seeds. Transperitoneal implantation allows errors in placement that cause suboptimal dosimetry. Conventional ultrasound cannot reliably image implanted seeds; therefore, seed misplacements cannot be corrected in the operating room. Previously, an algorithm based on singular spectrum analysis was shown to image palladium seeds better than B-mode ultrasound could. The algorithm is now applied to imaging an iodine seed in gel and in beef tissue as a function of seed angle relative to the incident ultrasound. Results indicate that both seed types are imaged reliably by the algorithm

    Determination of Carotid Plaque Risk By Ultrasonic Tissue Characterization.

    No full text
    This in vitro study investigated the ability of ultrasonic tissue characterization (UTC) to discriminate between plaques from asymptomatic and symptomatic patients and to compare UTC findings with quantitative measurements of plaque morphology. A total of 34 plaque specimens removed at carotid endarterectomy were scanned transversely at intervals of 1 mm, and compared to tissue cross-sections examined by optical microscopy employing computer-assisted planimetry. UTC was performed by spectral analysis of backscattered radiofrequency signals. The slope, intercept and total power parameters of the spectrum were evaluated. Discriminant analysis was used to compare the ability of the UTC spectral parameters and morphological constituents to correctly classify plaques according to their symptom group membership. UTC correctly classified 88.2% of the plaques. Thrombus was present in 93.9% of the plaques, and there was little difference in the morphological constituents of plaques from asymptomatic and symptomatic patients. Morphological constituents correctly classified 60.7% of the plaques. We conclude, in this preliminary study, that UTC can discriminate between carotid plaques from asymptomatic and symptomatic patients with moderate accuracy, despite a similarity in their morphological composition. UTC discrimination is not related to differences in the type or amount of morphological constituents in the plaques
    corecore