3 research outputs found

    Impact of the lockdown on acute stroke treatments during the first surge of the COVID-19 outbreak in the Netherlands

    Get PDF
    INTRODUCTION: We investigated the impact of the Corona Virus Disease 2019 (COVID-19) pandemic and the resulting lockdown on reperfusion treatments and door-to-treatment times during the first surge in Dutch comprehensive stroke centers. Furthermore, we studied the association between COVID-19-status and treatment times. METHODS: We included all patients receiving reperfusion treatment in 17 Dutch stroke centers from May 11th, 2017, until May 11th, 2020. We collected baseline characteristics, National Institutes of Health Stroke Scale (NIHSS) at admission, onset-to-door time (ODT), door-to-needle time (DNT), door-to-groin time (DGT) and COVID-19-status at admission. Parameters during the lockdown (March 15th, 2020 until May 11th, 2020) were compared with those in the same period in 2019, and between groups stratified by COVID-19-status. We used nationwide data and extrapolated our findings to the increasing trend of EVT numbers since May 2017. RESULTS: A decline of 14% was seen in reperfusion treatments during lockdown, with a decline in both IVT and EVT delivery. DGT increased by 12 min (50 to 62 min, p-value of < 0.001). Furthermore, median NIHSS-scores were higher in COVID-19 - suspected or positive patients (7 to 11, p-value of 0.004), door-to-treatment times did not differ significantly when stratified for COVID-19-status. CONCLUSIONS: During the first surge of the COVID-19 pandemic, a decline in acute reperfusion treatments and a delay in DGT was seen, which indicates a target for attention. It also appeared that COVID-19-positive or -suspected patients had more severe neurologic symptoms, whereas their EVT-workflow was not affected. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12883-021-02539-4

    Mobility particle size spectrometers: harmonization of technical standards and data structure to facilitate high quality long-term observations of atmospheric particle number size distributions

    No full text
    Mobility particle size spectrometers often referred to as DMPS (Differential Mobility Particle Sizers) or SMPS (Scanning Mobility Particle Sizers) have found a wide range of applications in atmospheric aerosol research. However, comparability of measurements conducted world-wide is hampered by lack of generally accepted technical standards and guidelines with respect to the instrumental set-up, measurement mode, data evaluation as well as quality control. Technical standards were developed for a minimum requirement of mobility size spectrometry to perform long-term atmospheric aerosol measurements. Technical recommendations include continuous monitoring of flow rates, temperature, pressure, and relative humidity for the sheath and sample air in the differential mobility analyzer. We compared commercial and custom-made inversion routines to calculate the particle number size distributions from the measured electrical mobility distribution. All inversion routines are comparable within few per cent uncertainty for a given set of raw data. Furthermore, this work summarizes the results from several instrument intercomparison workshops conducted within the European infrastructure project EUSAAR (European Supersites for Atmospheric Aerosol Research) and ACTRIS (Aerosols, Clouds, and Trace gases Research InfraStructure Network) to determine present uncertainties especially of custom-built mobility particle size spectrometers. Under controlled laboratory conditions, the particle number size distributions from 20 to 200 nm determined by mobility particle size spectrometers of different design are within an uncertainty range of around ±10% after correcting internal particle losses, while below and above this size range the discrepancies increased. For particles larger than 200 nm, the uncertainty range increased to 30%, which could not be explained. The network reference mobility spectrometers with identical design agreed within ±4% in the peak particle number concentration when all settings were done carefully. The consistency of these reference instruments to the total particle number concentration was demonstrated to be less than 5%. Additionally, a new data structure for particle number size distributions was introduced to store and disseminate the data at EMEP (European Monitoring and Evaluation Program). This structure contains three levels: raw data, processed data, and final particle size distributions. Importantly, we recommend reporting raw measurements including all relevant instrument parameters as well as a complete documentation on all data transformation and correction steps. These technical and data structure standards aim to enhance the quality of long-term size distribution measurements, their comparability between different networks and sites, and their transparency and traceability back to raw data.JRC.H.2-Air and Climat
    corecore