34 research outputs found
Impact of route of access and stenosis subtype on outcome after transcatheter aortic valve replacement
Introduction: Previous analyses have reported the outcomes of transcatheter aortic valve replacement (TAVR) for patients with low-flow, low-gradient (LFLG) aortic stenosis (AS), without stratifying according to the route of access. Differences in mortality rates among access routes have been established for high-gradient (HG) patients and hypothesized to be even more pronounced in LFLG AS patients. This study aims to compare the outcomes of patients with LFLG or HG AS following transfemoral (TF) or transapical (TA) TAVR.
Methods: A total of 910 patients, who underwent either TF or TA TAVR with a median follow-up of 2.22 (IQR: 1.22-4.03) years, were included in this multicenter cohort study. In total, 146 patients (16.04%) suffered from LFLG AS. The patients with HG and LFLG AS were stratified according to the route of access and compared statistically.
Results: The operative mortality rates of patients with HG and LFLG were found to be comparable following TF access. The operative mortality rate was significantly increased for patients who underwent TA access [odds ratio (OR): 2.91 (1.54-5.48), p = 0.001] and patients with LFLG AS [OR: 2.27 (1.13-4.56), p = 0.02], which could be corroborated in a propensity score-matched subanalysis. The observed increase in the risk of operative mortality demonstrated an additive effect [OR for TA LFLG: 5.45 (2.35-12.62), p < 0.001]. LFLG patients who underwent TA access had significantly higher operative mortality rates (17.78%) compared with TF LFLG (3.96%, p = 0.016) and TA HG patients (6.36%, p = 0.024).
Conclusions: HG patients experienced a twofold increase in operative mortality rates following TA compared with TF access, while LFLG patients had a fivefold increase in operative mortality rates. TA TAVR appears suboptimal for patients with LFLG AS. Prospective studies should be conducted to evaluate alternative options in cases where TF is not possible
Impact of route of access and stenosis subtype on outcome after transcatheter aortic valve replacement.
INTRODUCTION
Previous analyses have reported the outcomes of transcatheter aortic valve replacement (TAVR) for patients with low-flow, low-gradient (LFLG) aortic stenosis (AS), without stratifying according to the route of access. Differences in mortality rates among access routes have been established for high-gradient (HG) patients and hypothesized to be even more pronounced in LFLG AS patients. This study aims to compare the outcomes of patients with LFLG or HG AS following transfemoral (TF) or transapical (TA) TAVR.
METHODS
A total of 910 patients, who underwent either TF or TA TAVR with a median follow-up of 2.22 (IQR: 1.22-4.03) years, were included in this multicenter cohort study. In total, 146 patients (16.04%) suffered from LFLG AS. The patients with HG and LFLG AS were stratified according to the route of access and compared statistically.
RESULTS
The operative mortality rates of patients with HG and LFLG were found to be comparable following TF access. The operative mortality rate was significantly increased for patients who underwent TA access [odds ratio (OR): 2.91 (1.54-5.48), p = 0.001] and patients with LFLG AS [OR: 2.27 (1.13-4.56), p = 0.02], which could be corroborated in a propensity score-matched subanalysis. The observed increase in the risk of operative mortality demonstrated an additive effect [OR for TA LFLG: 5.45 (2.35-12.62), p < 0.001]. LFLG patients who underwent TA access had significantly higher operative mortality rates (17.78%) compared with TF LFLG (3.96%, p = 0.016) and TA HG patients (6.36%, p = 0.024).
CONCLUSIONS
HG patients experienced a twofold increase in operative mortality rates following TA compared with TF access, while LFLG patients had a fivefold increase in operative mortality rates. TA TAVR appears suboptimal for patients with LFLG AS. Prospective studies should be conducted to evaluate alternative options in cases where TF is not possible
A Neuronal Network-Based Score Predicting Survival in Patients Undergoing Aortic Valve Intervention: The ABC-AS Score.
Background: Despite being the most commonly performed valvular intervention, risk prediction for aortic valve replacement in patients with severe aortic stenosis by currently used risk scores remains challenging. The study aim was to develop a biomarker-based risk score by means of a neuronal network. Methods: In this multicenter study, 3595 patients were divided into test and validation cohorts (70% to 30%) by random allocation. Input variables to develop the ABC-AS score were age, the cardiac biomarker high-sensitivity troponin T, and a patient history of cardiac decompensation. The validation cohort was used to verify the scores' value and for comparison with the Society of Thoracic Surgery Predictive Risk of Operative Mortality score. Results: Receiver operating curves demonstrated an improvement in prediction by using the ABC-AS score compared to the Society of Thoracic Surgery Predictive Risk of Operative Mortality (STS prom) score. Although the difference in predicting cardiovascular mortality was most notable at 30-day follow-up (area under the curve of 0.922 versus 0.678), ABC-AS also performed better in overall follow-up (0.839 versus 0.699). Furthermore, univariate analysis of ABC-AS tertiles yielded highly significant differences for all-cause (p < 0.0001) and cardiovascular mortality (p < 0.0001). Head-to-head comparison between both risk scores in a multivariable cox regression model underlined the potential of the ABC-AS score (HR per z-unit 2.633 (95% CI 2.156-3.216), p < 0.0001), while the STS prom score failed to reach statistical significance (p = 0.226). Conclusions: The newly developed ABC-AS score is an improved risk stratification tool to predict cardiovascular outcomes for patients undergoing aortic valve intervention
A new web-based method for automated analysis of muscle histology
Background: Duchenne Muscular Dystrophy is an inherited degenerative neuromuscular disease characterised by rapidly progressive muscle weakness. Currently, curative treatment is not available. Approaches for new treatments that improve muscle strength and quality of life depend on preclinical testing in animal models. The mdx mouse model is the most frequently used animal model for preclinical studies in muscular dystrophy research. Standardised pathology-relevant parameters of dystrophic muscle in mdx mice for histological analysis have been developed in international, collaborative efforts, but automation has not been accessible to most research groups. A standardised and mainly automated quantitative assessment of histopathological parameters in the mdx mouse model is desirable to allow an objective comparison between laboratories.
Methods: Immunological and histochemical reactions were used to obtain a double staining for fast and slow myosin. Additionally, fluorescence staining of the myofibre membranes allows defining the minimal Feret's diameter. The staining of myonuclei with the fluorescence dye bisbenzimide H was utilised to identify nuclei located internally within myofibres. Relevant structures were extracted from the image as single objects and assigned to different object classes using web-based image analysis (MyoScan). Quantitative and morphometric data were analysed, e. g. the number of nuclei per fibre and minimal Feret's diameter in 6 month old wild-type C57BL/10 mice and mdx mice.
Results: In the current version of the module "MyoScan", essential parameters for histologic analysis of muscle sections were implemented including the minimal Feret’s diameter of the myofibres and the automated calculation of the percentage of internally nucleated myofibres. Morphometric data obtained in the present study were in good agreement with previously reported data in the literature and with data obtained from manual analysis.
Conclusions: A standardised and mainly automated quantitative assessment of histopathological parameters in the mdx mouse model is now available. Automated analysis of histological parameters is more rapid and less time-consuming. Moreover, results are unbiased and more reliable. Efficacy of therapeutic interventions, e.g. within the scope of a drug screening or therapeutic exon skipping, can be monitored. The automatic analysis system MyoScan used in this study is not limited exclusively to dystrophin-deficient mice but also represents a useful tool for applications in the research of other dystrophic pathologies, various other skeletal muscle diseases and degenerative neuromuscular disorders
institute for biomedical engineering
Model-based segmentation techniques for fast volume conductor generatio