19 research outputs found
The dilemma of recalling well-circumscribed masses in a screening population: A narrative literature review and exploration of Dutch screening practice
Background: In Dutch breast cancer screening, solitary, new or growing well-circumscribed masses should be recalled for further assessment. This results in cancers detected but also in false positive recalls, especially at initial screening. The aim of this study was to determine characteristics of well-circumscribed masses at mammography and identify potential methods to improve the recall strategy. Methods: A systematic literature search was performed using PubMed. In addition, follow-up data were retrieved on all 8860 recalled women in a Dutch screening region from 2014 to 2019. Results: Based on 15 articles identified in the literature search, we found that probably benign well-circumscribed masses that were kept under surveillance had a positive predictive value (PPV) of 0–2%. New or enlarging solitary well-circumscribed masses had a PPV of 10–12%. In general the detected carcinomas had a favorable prognosis. In our exploration of screening practice, 25% of recalls (2133/8860) were triggered by a well-circumscribed mass. Those recalls had a PPV of 2.0% for initial and 10.6% for subsequent screening. Most detected carcinomas had a favorable prognosis as well. Conclusion: To recognize malignancies presenting as well-circumscribed masses, identifying solitary, new or growing lesions is key. This information is missing at initial screening since prior examinations are not available, leading to a low PPV. Access to prior clinical examinations may therefore improve this PPV. In addition, given the generally favorable prognosis of screen-detected malignant well-circumscribed masses, one may opt to recall these lesions at subsequent screening, if grown, rather than at initial screening
Current management and prognostic factors in physiotherapy practice for patients with shoulder pain: Design of a prospective cohort study
Background: Shoulder pain is disabling and has a considerable socio-economic impact. Over 50% of patients presenting in primary care still have symptoms after 6 months; moreover, prognostic factors such as pain intensity, age, disability level and duration of complaints are associated with poor outcome. Most shoulder complaints in this group are categorized as non-specific. Musculoskeletal ultrasound might be a useful imaging method to detect subgroups of patients with subacromial disorders.This article describes the design of a prospective cohort study evaluating the influence of known prognostic and possible prognostic factors, such as findings from musculoskeletal ultrasound outcome and working alliance, on the recovery of shoulder pain. Also, to assess the usual physiotherapy care for shoulder pain and examine the inter-rater reliability of musculoskeletal ultrasound between radiologists and physiotherapists for patients with shoulder pain. Methods. A prospective cohort study including an inter-rater reliability study. Patients presenting in primary care physiotherapy practice with shoulder pain are enrolled. At baseline validated questionnaires are used to measure patient characteristics, disease-specific characteristics and social factors. Physical examination is performed according to the expertise of the physiotherapists. Follow-up measurements will be performed 6, 12 and 26 weeks after inclusion. Primary outcome measure is perceived recovery, measured on a 7-point Likert scale. Logistic regression analysis will be used to evaluate the association between prognostic factors and recovery. Discussion. The ShoCoDiP (Shoulder Complaints and using Diagnostic ultrasound in Physiotherapy practice) cohort study will provide information on current management of patients with shoulder pain in primary care, provide data to develop a prediction model for shoulder pain in primary care and to evaluate whether musculoskeletal ultrasound can improve prognosis
Long-term Survival in Breast Cancer Patients Is Associated with Contralateral Parenchymal Enhancement at MRI: Outcomes of the SELECT Study
Background Several single-center studies found that high contralateral parenchymal enhancement (CPE) at breast MRI was associated with improved long-term survival in patients with estrogen receptor (ER)-positive and human epidermal growth factor receptor 2 (HER2)-negative breast cancer. Due to varying sample sizes, population characteristics, and follow-up times, consensus of the association is currently lacking. Purpose To confirm whether CPE is associated with long-term survival in a large multicenter retrospective cohort, and to investigate if CPE is associated with endocrine therapy effectiveness. Materials and Methods This multicenter observational cohort included women with unilateral ER-positive HER2-negative breast cancer (tumor size ≤50 mm and ≤three positive lymph nodes) who underwent MRI from January 2005 to December 2010. Overall survival (OS), recurrence-free survival (RFS), and distant RFS (DRFS) were assessed. Kaplan-Meier analysis was performed to investigate differences in absolute risk after 10 years, stratified according to CPE tertile. Multivariable Cox proportional hazards regression analysis was performed to investigate whether CPE was associated with prognosis and endocrine therapy effectiveness. Results Overall, 1432 women (median age, 54 years [IQR, 47-63 years]) were included from 10 centers. Differences in absolute OS after 10 years were stratified according to CPE tertile as follows: 88.5% (95% CI: 88.1, 89.1) in tertile 1, 85.8% (95% CI: 85.2, 86.3) in tertile 2, and 85.9% (95% CI: 85.4, 86.4) in tertile 3. CPE was independently associated with OS, with a hazard ratio (HR) of 1.17 (95% CI: 1.0, 1.36; P = .047), but was not associated with RFS (HR, 1.11; P = .16) or DRFS (HR, 1.11; P = .19). The effect of endocrine therapy on survival could not be accurately assessed; therefore, the association between endocrine therapy efficacy and CPE could not reliably be estimated. Conclusion High contralateral parenchymal enhancement was associated with a marginally decreased overall survival in patients with estrogen receptor-positive and human epidermal growth factor receptor 2-negative breast cancer, but was not associated with recurrence-free survival (RFS) or distant RFS. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Honda and Iima in this issue
Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures
Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo
The dilemma of recalling well-circumscribed masses in a screening population: A narrative literature review and exploration of Dutch screening practice.
BACKGROUND: In Dutch breast cancer screening, solitary, new or growing well-circumscribed masses should be recalled for further assessment. This results in cancers detected but also in false positive recalls, especially at initial screening. The aim of this study was to determine characteristics of well-circumscribed masses at mammography and identify potential methods to improve the recall strategy. METHODS: A systematic literature search was performed using PubMed. In addition, follow-up data were retrieved on all 8860 recalled women in a Dutch screening region from 2014 to 2019. RESULTS: Based on 15 articles identified in the literature search, we found that probably benign well-circumscribed masses that were kept under surveillance had a positive predictive value (PPV) of 0-2%. New or enlarging solitary well-circumscribed masses had a PPV of 10-12%. In general the detected carcinomas had a favorable prognosis. In our exploration of screening practice, 25% of recalls (2133/8860) were triggered by a well-circumscribed mass. Those recalls had a PPV of 2.0% for initial and 10.6% for subsequent screening. Most detected carcinomas had a favorable prognosis as well. CONCLUSION: To recognize malignancies presenting as well-circumscribed masses, identifying solitary, new or growing lesions is key. This information is missing at initial screening since prior examinations are not available, leading to a low PPV. Access to prior clinical examinations may therefore improve this PPV. In addition, given the generally favorable prognosis of screen-detected malignant well-circumscribed masses, one may opt to recall these lesions at subsequent screening, if grown, rather than at initial screening
Pain Experience and Image Quality with Curved versus Standard Compression for Breast Cancer Screening Mammography: A Randomized Controlled Trial
Background A curve-shaped compression paddle could reduce the pain experienced by some women at breast cancer screening. Purpose To compare curved and standard compression systems in terms of pain experience and image quality in mammography screening. Materials and Methods In this randomized controlled trial conducted between October 2021 and February 2022, participants screened at three screening sites in the Netherlands were randomized to either a curved-paddle or sham-paddle group. The sham paddle was a standard paddle that was presented as a new paddle. At a standard screening examination, one additional image was acquired with a curved or sham paddle. Pain was measured on a numerical rating scale (range, 0-10). Participants provided a pain score after compression with the standard and test paddles, resulting in two scores per participant. Differences in pain scores were compared between groups using analysis of covariance, adjusting for pain score after standard-paddle compression. Two radiographers and two radiologists performed unblinded paired comparisons of curved-paddle vs standard-paddle images, using standard image quality criteria (radiographers evaluated 1246 image pairs using 12 criteria; radiologists evaluated 320 image pairs using six criteria). The one-sample Wilcoxon signed-rank test was used to determine if there was a significant preference for either paddle. Results In total, 2499 female participants (mean age, 61.6 years ± 7.1 [SD]) were studied; 1250 in the curved-paddle group and 1249 in the sham-paddle group. The mean pain score decreased by an additional 0.19 points in the curved-paddle group compared with the sham-paddle group (95% CI: 0.09, 0.28; P .99) and visibility of structures were the main concerns for curved-paddle images. Conclusion The use of the curved paddle resulted in a minimal pain reduction during mammography breast compression but image quality was reduced
Added Value of Prereading Screening Mammograms for Breast Cancer by Radiologic Technologists on Early Screening Outcomes
Item does not contain fulltex