28 research outputs found

    Independent Risk Factors for Fast-Track Failure Using a Predefined Fast-Track Protocol in Preselected Cardiac Surgery Patients

    Get PDF
    ObjectisvesThe purpose of this study was to identify the independent risk factors for fast-track failure (FTF) in cardiac surgery patients.DesignA retrospective analysis.SettingA university-affiliated heart center.ParticipantsIn a 2-year period, 1,704 consecutive preselected patients undergoing elective cardiac surgery were treated according to the local fast-track protocol in the postanesthetic care unit (PACU), bypassing the intensive care unit (ICU).Measurements and ResultsIndependent risk factors for FTF in the univariate regression analysis were tested in a multivariate regression analysis. FTF was defined as any transfer of the preselected patient to the ICU. FTF was primary when the patient was transferred directly from the postanesthetic care unit to the ICU and secondary when the patient was transferred from the intermediate care unit or ward to the ICU. FTF rate was 11.6% for primary and 5.6% for secondary FTF. In the multivariate regression analysis, age>70 years, female sex, prolonged surgery, and prolonged cross-clamp time could be defined as independent risk factors for FTF.ConclusionsIn a preselected patient population, fast-track treatment could be done with a low FTF rate. Independent risk factors for FTF are age, female sex, prolonged surgery, and prolonged cross-clamp time

    Current Anesthetic Care of Patients Undergoing Transcatheter Aortic Valve Replacement in Europe:Results of an Online Survey

    Get PDF
    Objectives: Transcatheter aortic valve replacement (TAVR) has become an alternative treatment for patients with symptomatic aortic stenosis not eligible for surgical valve replacement due to a high periprocedural risk or comorbidities. However, there are several areas of debate concerning the pre-, intra- and post-procedural management. The standards and management for these topics may vary widely among different institutions and countries in Europe. Design: Structured web-based, anonymized, voluntary survey. Setting: Distribution of the survey via email among members of the European Association of Cardiothoracic Anaesthesiology working in European centers performing TAVR between September and December 2018. Participants: Physicians. Measurements and main results: The survey consisted of 25 questions, including inquiries regarding number of TAVR procedures, technical aspects of TAVR, medical specialities present, preoperative evaluation of TAVR candidates, anesthesia regimen, as well as postoperative management. Seventy members participated in the survey. Reporting members mostly performed 151-to-300 TAVR procedures per year. In 90% of the responses, a cardiologist, cardiac surgeon, cardiothoracic anesthesiologist, and perfusionist always were available. Sixty-six percent of the members had a national curriculum for cardiothoracic anesthesia. Among 60% of responders, the decision for TAVR was made preoperatively by an interdisciplinary heart team with a cardiothoracic anesthesiologist, yet in 5 countries an anesthesiologist was not part of the decision-making. General anesthesia was employed in 40% of the responses, monitored anesthesia care in 44%, local anesthesia in 23%, and in 49% all techniques were offered to the patients. In cases of general anesthesia, endotracheal intubation almost always was performed (91%). It was stated that norepinephrine was the vasopressor of choice (63% of centers). Transesophageal echocardiography guiding, whether performed by an anesthesiologist or cardiologist, was used only Conclusion: The results indicated that requirements and quality indicators (eg, periprocedural anesthetic management, involvement of the anesthesiologist in the heart team, etc) for TAVR procedures as published within the European guideline are largely, yet still not fully implemented in daily routine. In addition, anesthetic TAVR management also is performed heterogeneously throughout Europe. (C) 2020 Elsevier Inc. All rights reserved

    Outcomes of elective liver surgery worldwide: a global, prospective, multicenter, cross-sectional study

    Get PDF
    Background: The outcomes of liver surgery worldwide remain unknown. The true population-based outcomes are likely different to those vastly reported that reflect the activity of highly specialized academic centers. The aim of this study was to measure the true worldwide practice of liver surgery and associated outcomes by recruiting from centers across the globe. The geographic distribution of liver surgery activity and complexity was also evaluated to further understand variations in outcomes. Methods: LiverGroup.org was an international, prospective, multicenter, cross-sectional study following the Global Surgery Collaborative Snapshot Research approach with a 3-month prospective, consecutive patient enrollment within January–December 2019. Each patient was followed up for 90 days postoperatively. All patients undergoing liver surgery at their respective centers were eligible for study inclusion. Basic demographics, patient and operation characteristics were collected. Morbidity was recorded according to the Clavien–Dindo Classification of Surgical Complications. Country-based and hospital-based data were collected, including the Human Development Index (HDI). (NCT03768141). Results: A total of 2159 patients were included from six continents. Surgery was performed for cancer in 1785 (83%) patients. Of all patients, 912 (42%) experienced a postoperative complication of any severity, while the major complication rate was 16% (341/2159). The overall 90-day mortality rate after liver surgery was 3.8% (82/2,159). The overall failure to rescue rate was 11% (82/ 722) ranging from 5 to 35% among the higher and lower HDI groups, respectively. Conclusions: This is the first to our knowledge global surgery study specifically designed and conducted for specialized liver surgery. The authors identified failure to rescue as a significant potentially modifiable factor for mortality after liver surgery, mostly related to lower Human Development Index countries. Members of the LiverGroup.org network could now work together to develop quality improvement collaboratives

    Real-time three-dimensional echocardiographic assessment of mitral valve: Is it really superior to 2D transesophageal echocardiography?

    No full text
    Aim of our study was to investigate the feasibility of use and possible additional value of real-time 3D transesophageal echocardiography (RT-3D-TEE) compared to conventional 2D-TEE in patients undergoing elective mitral valve repair. After ethical committee approval, patients were included in this prospective study. After induction of anesthesia, a comprehensive 2D-TEE examination was performed, followed with RT-3D-TEE. The intraoperative surgical finding was used as the gold standard for segmental analysis. Only such segments which were surgically corrected either by resection or insertion of artificial chords were judged pathologic. A total of 50 patients were included in this study; usable data were available from 42 of these patients . Based on the Carpentier classification, the pathology found was type I in 2 (5%) patients, type II in 39 (93%) patients and type IIIb in 1 (2%) patient. We found that 3D imaging of complex mitral disease involving multiple segments, when compared to 2D-TEE did not show any statistically significant difference.RT-3D-TEE did not show any major advantage when compared to conventional 2D-TEE for assessing mitral valve pathology, although further study in a larger population is required to establish the validity of this study

    Innovative Thinking in the Care of Cardiac Surgical Patients

    No full text

    Transesophageal echocardiography for verification of the position of the electrocardiographically-placed central venous catheter

    No full text
    OBJECTIVE: Compare changes in P-wave amplitude of the intra-atrial electrocardiogram (ECG) and its corresponding transesophageal echocardiography (TEE)-controlled position to verify the exact localization of a central venous catheter (CVC) tip. DESIGN: A prospective study. SETTING: University, single-institutional setting. PARTICIPANTS: Two hundred patients undergoing elective cardiac surgery. INTERVENTIONS: CVC placement via the right internal jugular vein with ECG control using the guidewire technique and TEE control in 4 different phases: phase 1: CVC placement with normalized P wave and measurement of distance from the crista terminalis to the CVC tip; phase 2: TEE-controlled placement of the CVC tip; parallel to the superior vena cava (SVC) and measurements of P-wave amplitude; phase 3: influence of head positioning on CVC migration; and phase 4: evaluation of positioning of the CVC postoperatively using a chest x-ray. MEASUREMENTS AND MAIN RESULTS: The CVC tip could only be visualized in 67 patients on TEE with a normalized P wave. In 198 patients with the CVC parallel to the SVC wall controlled by TEE (phase 2), an elevated P wave was observed. Different head movements led to no significant migration of the CVC (phase 3). On a postoperative chest-x-ray, the CVC position was correct in 87.6% (phase 4). CONCLUSION: The study suggests that the position of the CVC tip is located parallel to the SVC and 1.5 cm above the crista terminalis if the P wave starts to decrease during withdrawal of the catheter. The authors recommend that ECG control as per their study should be routinely used for placement of central venous catheters via the right internal jugular vein

    Intrathecal morphine is superior to intravenous PCA in patients undergoing minimally invasive cardiac surgery

    No full text
    Aim of our study was to evaluate the beneficial effect of low dose intrathecal morphine on postoperative analgesia, over the use of intravenous patient controlled anesthesia (PCA), in patients undergoing fast track anesthesia during minimally invasive cardiac surgical procedures. A randomized controlled trial was undertaken after approval from local ethical committee. Written informed consent was obtained from 61 patients receiving mitral or tricuspid or both surgical valve repair in minimal invasive technique. Patients were assigned randomly to 2 groups. Group 1 received general anesthesia and intravenous patient controlled analgesia (PCA) pump with Piritramide (GA group). Group 2 received a single shot of intrathecal morphine (1.5 μg/kg body weight) prior to the administration of general anesthesia (ITM group). Site of puncture was confined to lumbar (L1-2 or L2-3) intrathecal space. The amount of intravenous piritramide used in post anesthesia care unit (PACU) and the first postoperative day was defined as primary end point. Secondary end points included: time for tracheal extubation, pain and sedation scores in PACU upto third postoperative day. For statistical analysis Mann-Whitney-U Test and Fishers exact test (SPSS) were used. We found that the demand for intravenous opioids in PACU was significantly reduced in ITM group (P <0.001). Pain scores were significantly decreased in ITM group until second postoperative day (P <0.01). There was no time delay for tracheal extubation in ITM group, and sedation scores did not differ in either group. We conclude that low dose single shot intrathecal morphine provides adequate postoperative analgesia, reduces the intravenous opioid consumption during the early postoperative period and does not defer early extubation
    corecore