1 research outputs found
Pressurized Liquid Extraction of Diesel and Air Particulate Standard Reference Materials: Effect of Extraction Temperature and Pressure
Four particulate matter Standard Reference Materials
(SRMs) available from the National Institute of Standards and Technology
(NIST) were used to evaluate the effect of solvent, number of static
cycles and static times, pressure, and temperature when using pressurized
liquid extraction (PLE) for the extraction of polycyclic aromatic
hydrocarbons (PAHs) and nitrated-PAHs. The four materials used in
the study were SRM 1648a Urban Particulate Matter, SRM 1649b Urban
Dust, SRM 1650b Diesel Particulate Matter, and SRM 2975 Diesel Particulate
Matter (Industrial Forklift). The results from the study indicate
that the choice of solvent, dichloromethane compared to toluene and
toluene/methanol mixtures, had little effect on the extraction efficiency.
With three to five extraction cycles, increasing the extraction time
for each cycle from 5 to 30 min had no significant effect on the extraction
efficiency. The differences in extraction efficiency were not significant
(with over 95% of the differences being <10%) when the pressure
was increased from 13.8 to 20.7 MPa. The largest increase in extraction
efficiency occurred for selected PAHs when the temperature of extraction
was increased from 100 to 200 °C. At 200 °C naphthalene,
biphenyl, fluorene, dibenzothiophene, and anthracene show substantially
higher mass fractions (>30%) than when extracted at 100 °C
in all the SRMs studied. For SRM 2975, large increases (>100%)
are also observed for some other PAHs including benz[<i>a</i>]anthracene, benzo[<i>k</i>]fluoranthene, benzo[<i>e</i>]pyrene, benzo[<i>a</i>]pyrene, benzo[<i>ghi</i>]perylene, and benzo[<i>b</i>]chrysene when
extracted at the higher temperatures; however, similar trends were
not observed for the other diesel particulate sample, SRM 1650b. The
results are discussed in relation to the use of the SRMs for evaluating
analytical methods