4 research outputs found

    Extubation Failure after Neonatal Cardiac Surgery: A Multicenter Analysis

    Get PDF
    Objectives To describe the epidemiology of extubation failure and identify risk factors for its occurrence in a multicenter population of neonates undergoing surgery for congenital heart disease. Study design We conducted a prospective observational study of neonates ≤30 days of age who underwent cardiac surgery at 7 centers within the US in 2015. Extubation failure was defined as reintubation within 72 hours of the first planned extubation. Risk factors were identified with the use of multivariable logistic regression analysis and reported as OR with 95% CIs. Multivariable logistic regression analysis was conducted to examine the relationship between extubation failure and worse clinical outcome, defined as hospital length of stay in the upper 25% or operative mortality. Results We enrolled 283 neonates, of whom 35 (12%) failed their first extubation at a median time of 7.5 hours (range 1-70 hours). In a multivariable model, use of uncuffed endotracheal tubes (OR 4.6; 95% CI 1.8-11.6) and open sternotomy of 4 days or more (OR 4.8; 95% CI 1.3-17.1) were associated independently with extubation failure. Accordingly, extubation failure was determined to be an independent risk factor for worse clinical outcome (OR 5.1; 95% CI 2-13). Conclusions In this multicenter cohort of neonates who underwent surgery for congenital heart disease, extubation failure occurred in 12% of cases and was associated independently with worse clinical outcome. Use of uncuffed endotracheal tubes and prolonged open sternotomy were identified as independent and potentially modifiable risk factors for the occurrence of this precarious complication

    Near-Infrared Spectroscopy for Prediction of Extubation Success after Neonatal Cardiac Surgery

    Get PDF
    Introduction: Reliable predictors of extubation readiness are needed and may reduce morbidity related to extubation failure. We aimed to examine the relationship between changes in pre-extubation near-infrared spectroscopy measurements from baseline and extubation outcomes after neonatal cardiac surgery. Materials and Methods: In this retrospective cross-sectional multi-centre study, a secondary analysis of prospectively collected data from neonates who underwent cardiac surgery at seven tertiary-care children’s hospitals in 2015 was performed. Extubation failure was defined as need for re-intubation within 72 hours of the first planned extubation attempt. Near-infrared spectroscopy measurements obtained before surgery and before extubation in patients who failed extubation were compared to those of patients who extubated successfully using t-tests. Results: Near-infrared spectroscopy measurements were available for 159 neonates, including 52 with single ventricle physiology. Median age at surgery was 6 days (range: 1–29 days). A total of 15 patients (9.4 %) failed extubation. Baseline cerebral and renal near-infrared spectroscopy measurements were not statistically different between those who were successfully extubated and those who failed, but pre-extubation cerebral and renal values were significantly higher in neonates who extubated successfully. An increase from baseline to time of extubation values in cerebral oximetry saturation by ≥ 5 % had a positive predictive value for extubation success of 98.6 % (95%CI: 91.1–99.8 %). Conclusion: Pre-extubation cerebral near-infrared spectroscopy measurements, when compared to baseline, were significantly associated with extubation outcomes. These findings demonstrate the potential of this tool as a valuable adjunct in assessing extubation readiness after paediatric cardiac surgery and warrant further evaluation in a larger prospective study
    corecore