5 research outputs found

    An experimental animal model of aseptic loosening of hip prostheses in sheep to study early biochemical changes at the interface membrane

    Get PDF
    Background Aseptic loosening of hip prosthesis as it occurs in clinical cases in human patients was attributed to wear particles of the implants, the response of the tissue dominated by macrophages and the production of inflammatory mediators and matrix degrading enzymes; however, the cascade of events initiating the process and their interaction regarding the time course is still open and discussed controversially. Therefore, the goal of this study was to establish an experimental animal model in sheep allowing to follow the cascade of early mechanical and biochemical events within the interface membrane and study the sequence of how they contribute to the pathological bone resorption necessary for aseptic loosening of the implant. Methods A cemented modular system (Biomedtrix) was used as a hip replacement in 24 adult Swiss Alpine sheep, with one group receiving a complete cement mantle as controls (n = 12), and the other group a cement mantle with a standardized, lateral, primary defect in the cement mantle (n = 12). Animals were followed over time for 2 and 8.5 months (n = 6 each). After sacrifice, samples from the interface membranes were harvested from five different regions of the femur and joint capsule. Explant cell cultures were performed and supernatant of cultures were tested and assayed for nitric oxide, prostaglandin E2, caseinolytic and collagenolytic activity. RNA extraction and quantification were performed for inducible nitric oxide synthase, cyclooxygenase-2, interleukin 1, and interleukin 6. Overall differences between groups and time periods and interactions thereof were calculated using a factorial analysis of variance (ANOVA). Results The development of an interface membrane was noticed in both groups at both time points. However, in the controls the interface membrane regressed in thickness and biological activity, while both variables increased in the experimental group with the primary cement mantle defect over time. Nitric oxide (NO) and PGE2 concentrations were higher in the 8.5 months group (P < 0.0001) compared to the 2 months group with a tendency for the unstable group to have higher concentrations. The same was true for collagenolytic activity (P = 0.05), but not for caseinolytic activity that decreased over time (P < 0.0001). Conclusion In this study, a primary cement mantle defect of the femoral shaft elicited biomechanical instability and biochemical changes over time in an experimental animal study in sheep, that resembled the changes described at the bone cement-interface in aseptic loosening of total hip prosthesis in humans. The early biochemical changes may well explain the pathologic bone resorption and formation of an interface membrane as is observed in clinical cases. This animal model may aid in future studies aiming at prevention of aseptic loosening of hip prosthesis and reflect some aspects of the pathogenesis involved.ISSN:1471-247

    Gait analysis in clinically healthy sheep from three different age groups using a pressure-sensitive walkway

    No full text
    Background: Understanding normal gait requires allowing for variations in normal patterns by the sex, age, and species in question. Therefore, the aim of this study was to evaluate kinetic and temporospatial parameters in clinically healthy sheep from three different age groups with a pressure-sensing walkway. The sheep were judged to be healthy based on the results of complete physical and orthopaedic examinations and had no history of lameness. Twenty-one clinically healthy female Santa Ines sheep were divided into three groups: G1 - seven animals, aged from 8 to 12 months and weighing 19.5-33 kg; G2 - seven individuals, aged from 2 to 4 years and weighing 26.5-42 kg; and G3 - seven sheep, aged more than 5 years and weighing 37.3-45 kg. The animals were examined from two directions: first on the left side and then on the right side of the handler. The data from the first five valid trials in each direction were collected for each sheep and analysed using the designated software. A trial was considered valid if the sheep walked within the correct velocity (1.1-1.3 m/s) and acceleration (from -0.15 to 0.15 m/s(2)) ranges. The peak vertical force (PVF), vertical impulse (VI), gait cycle time, stance time, swing time, stride length, and the percentage body weight distribution among the four limbs were determined.Results: No significant differences were observed, in either the forelimbs or the hind limbs, between the left and right sides or between the two directions for any of the variables. No significant temporospatial differences were found among the groups. Significant PVF (%BW) differences were observed in the forelimbs (G1 > G3) and hind limbs (G1 > G3), and significant VI differences were observed in the forelimbs (G1 > G3).Conclusions: Young healthy sheep differ from older sheep in the vertical forces they create when walking at the same velocity on a pressure-sensing walkway

    Finite Element Modeling for Development and Optimization of a Bone Plate for Mandibular Fracture in Dogs

    No full text
    This study aimed to develop a plate to treat fractures of the mandibular body in dogs and to validate the project using finite elements and biomechanical essays. Mandible prototypes were produced with 10 oblique ventrorostral fractures (favorable) and 10 oblique ventrocaudal fractures (unfavorable). Three groups were established for each fracture type. Osteosynthesis with a pure titanium plate of double-arch geometry and blocked monocortical screws offree angulanon were used. The mechanical resistance of the prototype with unfavorable fracture was lower than that of the fcworable fracture. In both fractures, the deflection increased and the relative stiffness decreased proportionally to the diminishing screw number The finite element analysis validated this plate study, since the maximum tension concentration observed on the plate was lower than the resistance limit tension admitted by the titanium. In conclusion, the double-arch geometry plate fixed with blocked monocortical screws has sufficient resistance to stabilize oblique,fractures, without compromising mandibular dental or neurovascular structures. J Vet Dent 24 (7); 212 - 221, 201

    Finite Element Modeling for Development and Optimization of a Bone Plate for Mandibular Fracture in Dogs

    No full text
    This study aimed to develop a plate to treat fractures of the mandibular body in dogs and to validate the project using finite elements and biomechanical essays. Mandible prototypes were produced with 10 oblique ventrorostral fractures (favorable) and 10 oblique ventrocaudal fractures (unfavorable). Three groups were established for each fracture type. Osteosynthesis with a pure titanium plate of double-arch geometry and blocked monocortical screws offree angulanon were used. The mechanical resistance of the prototype with unfavorable fracture was lower than that of the fcworable fracture. In both fractures, the deflection increased and the relative stiffness decreased proportionally to the diminishing screw number The finite element analysis validated this plate study, since the maximum tension concentration observed on the plate was lower than the resistance limit tension admitted by the titanium. In conclusion, the double-arch geometry plate fixed with blocked monocortical screws has sufficient resistance to stabilize oblique,fractures, without compromising mandibular dental or neurovascular structures. J Vet Dent 24 (7); 212 - 221, 201
    corecore