532 research outputs found

    Investigation into the Hybrid Production of a Superelastic Shape Memory Alloy with Additively Manufactured Structures for Medical Implants

    Get PDF
    The demographic change in and the higher incidence of degenerative bone disease have resulted in an increase in the number of patients with osteoporotic bone tissue causing. amongst other issues, implant loosening. Revision surgery to treat and correct the loosenings should be avoided, because of the additional patient stress and high treatment costs. Shape memory alloys (SMA) can help to increase the anchorage stability of implants due to their superelastic behavior. The present study investigates the potential of hybridizing NiTi SMA sheets with additively manufactured Ti6Al4V anchoring structures using laser powder bed fusion (LPBF) technology to functionalize a pedicle screw. Different scanning strategies are evaluated, aiming for minimized warpage of the NiTi SMA sheet. For biomechanical tests, functional samples were manufactured. A good connection between the additively manufactured Ti6Al4V anchoring structures and NiTi SMA substrate could be observed though crack formation occurring at the transition area between the two materials. These cracks do not propagate during biomechanical testing, nor do they lead to flaking structures. In summary, the hybrid manufacturing of a NiTi SMA substrate with additively manufactured Ti6Al4V structures is suitable for medical implants

    A Comparison of Single- and Multiparametric MRI Models for Differentiation of Recurrent Glioblastoma from Treatment-Related Change

    No full text
    To evaluate single- and multiparametric MRI models to differentiate recurrent glioblastoma (GBM) and treatment-related changes (TRC) in clinical routine imaging. Selective and unselective apparent diffusion coefficient (ADC) and minimum, mean, and maximum cerebral blood volume (CBV) measurements in the lesion were performed. Minimum, mean, and maximum ratiosCBV (CBVlesion to CBVhealthy white matter) were computed. All data were tested for lesion discrimination. A multiparametric model was compiled via multiple logistic regression using data demonstrating significant difference between GBM and TRC and tested for its diagnostic strength in an independent patient cohort. A total of 34 patients (17 patients with recurrent GBM and 17 patients with TRC) were included. ADC measurements showed no significant difference between both entities. All CBV and ratiosCBV measurements were significantly higher in patients with recurrent GBM than TRC. A minimum CBV of 8.5, mean CBV of 116.5, maximum CBV of 327 and ratioCBV minimum of 0.17, ratioCBV mean of 2.26 and ratioCBV maximum of 3.82 were computed as optimal cut-off values. By integrating these parameters in a multiparametric model and testing it in an independent patient cohort, 9 of 10 patients, i.e., 90%, were classified correctly. The multiparametric model further improves radiological discrimination of GBM from TRC in comparison to single-parameter approaches and enables reliable identification of recurrent tumors

    Improved Detection of Cavernous Sinus Invasion of Pituitary Macroadenomas with Ultra-High-Field 7 T MRI

    No full text
    To compare 7 T magnetic resonance imaging (MRI) of pituitary macroadenomas (PMA) with standard MRI and intraoperative findings regarding tumor detection, localization, size, and extension. Patients with suspected pituitary adenoma underwent pre-operative 1.5 T or 3 T and 7 T MRI; 14 patients with a PMA were included. A qualitative (lesion detection, location, cavernous sinus infiltration) and quantitative (lesion size, depth of cavernous sinus infiltration) analysis of 1.5 T, 3 T and 7 T MRI was performed and compared with intraoperative findings. Both 1.5/3 T and 7 T MRI enabled the detection of all PMAs; lesion size determination was equal. 7 T MRI enables more precise assessments of cavernous sinus infiltration of PMA (ncorrect 7T = 78.6%, ncorrect 1.5/3T = 64.3%). Ultra-high-field MRI is a reliable imaging modality for evaluation of PMAs providing exact information on lesion location and size. 7 T MRI yielded more accurate information on cavernous sinus infiltration with better agreement with intraoperative findings than standard MRI

    Improved Detection of Cavernous Sinus Invasion of Pituitary Macroadenomas with Ultra-High-Field 7 T MRI

    No full text
    To compare 7 T magnetic resonance imaging (MRI) of pituitary macroadenomas (PMA) with standard MRI and intraoperative findings regarding tumor detection, localization, size, and extension. Patients with suspected pituitary adenoma underwent pre-operative 1.5 T or 3 T and 7 T MRI; 14 patients with a PMA were included. A qualitative (lesion detection, location, cavernous sinus infiltration) and quantitative (lesion size, depth of cavernous sinus infiltration) analysis of 1.5 T, 3 T and 7 T MRI was performed and compared with intraoperative findings. Both 1.5/3 T and 7 T MRI enabled the detection of all PMAs; lesion size determination was equal. 7 T MRI enables more precise assessments of cavernous sinus infiltration of PMA (ncorrect 7T = 78.6%, ncorrect 1.5/3T = 64.3%). Ultra-high-field MRI is a reliable imaging modality for evaluation of PMAs providing exact information on lesion location and size. 7 T MRI yielded more accurate information on cavernous sinus infiltration with better agreement with intraoperative findings than standard MRI

    A Comparison of Single- and Multiparametric MRI Models for Differentiation of Recurrent Glioblastoma from Treatment-Related Change

    No full text
    To evaluate single- and multiparametric MRI models to differentiate recurrent glioblastoma (GBM) and treatment-related changes (TRC) in clinical routine imaging. Selective and unselective apparent diffusion coefficient (ADC) and minimum, mean, and maximum cerebral blood volume (CBV) measurements in the lesion were performed. Minimum, mean, and maximum ratiosCBV (CBVlesion to CBVhealthy white matter) were computed. All data were tested for lesion discrimination. A multiparametric model was compiled via multiple logistic regression using data demonstrating significant difference between GBM and TRC and tested for its diagnostic strength in an independent patient cohort. A total of 34 patients (17 patients with recurrent GBM and 17 patients with TRC) were included. ADC measurements showed no significant difference between both entities. All CBV and ratiosCBV measurements were significantly higher in patients with recurrent GBM than TRC. A minimum CBV of 8.5, mean CBV of 116.5, maximum CBV of 327 and ratioCBV minimum of 0.17, ratioCBV mean of 2.26 and ratioCBV maximum of 3.82 were computed as optimal cut-off values. By integrating these parameters in a multiparametric model and testing it in an independent patient cohort, 9 of 10 patients, i.e., 90%, were classified correctly. The multiparametric model further improves radiological discrimination of GBM from TRC in comparison to single-parameter approaches and enables reliable identification of recurrent tumors

    Investigation into the Hybrid Production of a Superelastic Shape Memory Alloy with Additively Manufactured Structures for Medical Implants

    No full text
    The demographic change in and the higher incidence of degenerative bone disease have resulted in an increase in the number of patients with osteoporotic bone tissue causing. amongst other issues, implant loosening. Revision surgery to treat and correct the loosenings should be avoided, because of the additional patient stress and high treatment costs. Shape memory alloys (SMA) can help to increase the anchorage stability of implants due to their superelastic behavior. The present study investigates the potential of hybridizing NiTi SMA sheets with additively manufactured Ti6Al4V anchoring structures using laser powder bed fusion (LPBF) technology to functionalize a pedicle screw. Different scanning strategies are evaluated, aiming for minimized warpage of the NiTi SMA sheet. For biomechanical tests, functional samples were manufactured. A good connection between the additively manufactured Ti6Al4V anchoring structures and NiTi SMA substrate could be observed though crack formation occurring at the transition area between the two materials. These cracks do not propagate during biomechanical testing, nor do they lead to flaking structures. In summary, the hybrid manufacturing of a NiTi SMA substrate with additively manufactured Ti6Al4V structures is suitable for medical implants
    corecore