525 research outputs found

    Bibliometric Analysis of Ophthalmic Journals

    Get PDF
    Importance: The primary vehicle for reporting and testing advances in eye care is refereed ophthalmic journals, which can be characterized using targeted bibliometric analyses. Objective: To identify all ophthalmic journals and evaluate citation metrics relating to articles, journals, authors, institutions, and countries published therein. Design and Setting: A bibliometric analysis was undertaken of all ophthalmic journals included in the Scopus database (Elsevier). The search was restricted to all article types published in ophthalmic journals in English from inception through November 18, 2022. After excluding general medical journals, journals published in a language other than English, and spurious titles unrelated to the ophthalmic field, the Scopus database was found to list 335 ophthalmic journal titles that have published 471184 articles, constituting the data set for this analysis. The 20 most highly cited articles were identified. Rank-order lists by article count were assembled for journals, authors, institutions, and countries. Main Outcomes and Measures: An h-index for ophthalmic journal articles was derived from citations and article counts for each constituent of each category. Results: The h-index for ophthalmic journal articles was determined to be 494. The journal with the highest h-index was Ophthalmology (h-index, 297). The journal with the greatest number of articles was American Journal of Ophthalmology (38441 articles). The most highly cited article was by Quigley and Broman, 2006 (5147 citations), concerning the epidemiology of glaucoma. The author with the highest h-index for ophthalmic journal articles was Ronald Klein, MD (h-index, 126), and the most prolific was Carol L. Shields, MD (1400 articles). Johns Hopkins University (h-index, 215) was the institution with the highest h-index for ophthalmic journal articles, and Harvard University was the most prolific (10071 articles). The United States was the nation with the highest h-index for ophthalmic journal articles (h-index, 444) and was the most prolific (180017 articles). Conclusions and Relevance: In this study, the most highly cited articles published in ophthalmic journals were revealed, as well as the leading journals, authors, institutions, and countries. While excluding ophthalmology articles in general medical journals, this investigation affords a means of identifying highly cited authors, institutions, and countries which individuals or institutions can use as a guide regarding contributions to the field.</p

    Incidence of keratitis of varying severity among contact lens wearers

    Get PDF
    AIM: To determine the incidence of non-severe keratitis (NSK) and severe keratitis (SK) among wearers of current generation contact lenses. METHODS: A 12 month, prospective, hospital based epidemiological study was conducted by examining all contact lens wearers presenting with a corneal infiltrate/ulcer to a hospital centre in Manchester. A clinical severity matrix was used to differentiate between NSK and SK, based on the severity of signs and symptoms. The size of the hospital catchment population and the wearing modalities (daily wear (DW) or extended wear (EW)) and lens types being used were estimated from relevant demographic and market data. RESULTS: During the survey period, 80 and 38 patients presented with NSK and SK, respectively. The annual incidences (cases per 10,000 wearers) for each wearing modality and lens type were: DW rigid--NSK 5.7, SK 2.9; DW hydrogel daily disposable--NSK 9.1, SK 4.9; DW hydrogel (excluding daily disposable)--NSK 14.1, SK 6.4; DW silicone hydrogel--NSK 55.9, SK 0.0; EW rigid--NSK 0.0, SK 0.0; EW hydrogel--NSK 48.2, SK 96.4; EW silicone hydrogel--NSK 98.8, SK 19.8. The difference in SK between EW hydrogel and EW silicone hydrogel was significant (p = 0.04). CONCLUSIONS: A clinical severity matrix has considerable utility in assessing contact lens related keratitis. There is a significantly higher incidence of SK in wearers who sleep in contact lenses compared with those who only use lenses during the waking hours. Those who choose to sleep in lenses should be advised to wear silicone hydrogel lenses, which carry a five times decreased risk of SK for extended wear compared with hydrogel lenses

    Incidence and morbidity of hospital-presenting corneal infiltrative events associated with contact lens wear

    No full text
    Aim: To determine the incidence and morbidity (visual loss) of hospital-presenting corneal infiltrative events (CIEs) associated with the wearing of current generation contact lenses. Methods: All contact lens wearers presenting with any form of corneal infiltrate/ulcer to a hospital centre in Manchester, UK, were surveyed in this 12-month, prospective, hospital-based epidemiological study. A clinical severity matrix was used to quantify the overall severity of presenting signs and symptoms. The size of the hospital catchment population and the wearing modalities (daily wear [DW] or extended wear [EW]) and lens types used in that population were estimated from relevant demographic and market data to facilitate the calculation of incidence. We also attempted to ascertain, from their eye care practitioners, the visual acuity (VA) of patients suffering from CIEs prior to and at about six months following attendance at the hospital. Results: During the survey period, 118 patients presented with CIEs of varying severity. The annual incidence (cases per 10,000 wearers) for all wearing modalities and lens types is 21.3 (95 per cent confidence interval 17.8 to 25.5). The incidence of CIEs for each wearing modality and lens type is: DW rigid, 8.6 (3.9 to 18.7); DW hydrogel daily disposable, 14.0 (9.3 to 21.0); DW hydrogel (excluding daily disposable), 20.4 (15.9 to 26.2); DW silicone hydrogel, 55.9 (9.9 to 309.6); EW rigid, zero (0.0 to 1758.8); EW hydrogel, 144.6 (66.4 to 311.8) and EW silicone hydrogel, 118.6 (75.2 to 186.7). The risk of developing a CIE with EW lenses was 8.1 (5.3 to 12.5) times greater than that with DW lenses (p < 0.0001). Although there was no difference between EW hydrogel and EW silicone hydrogel lenses with respect to the risk of developing CIEs, the clinical severity of CIEs was greater with EW hydrogel lenses (p = 0.04). Results of VA for pre- and post-hospital attendance were obtained from 38 patients, none of whom lost more than one line of VA. For the study population, zero patients (95 per cent CI: 0 to 9.2 per cent) suffered a significant loss of VA as a result of developing a CIE. Conclusions: Overall, there is an eight times higher incidence of CIEs in wearers who sleep in contact lenses compared with wearers who use lenses only during the waking hours. For those who choose to routinely or intermittently sleep in soft contact lenses, silicone hydrogels are the lens of first choice because CIEs are less clinically severe with this lens type compared with hydrogel lenses. The rate of significant visual loss as a result of developing a CIE is low

    Comparative Clinical Performance Of Two Silicone Hydrogel Contact Lenses For Continuous Wear

    No full text
    BACKGROUND: Silicone hydrogel soft contact lenses are now available for use on a 30-day continuous wear basis. The aim of this study was to compare the clinical performance of two such lenses. METHODS: In a single-centre, randomised, subject-masked, two-period crossover study, 30 subjects wore a pair of PureVision lenses (Bausch &amp; Lomb) and a pair of Focus Night &amp; Day lenses (CIBA Vision), alternately, for successive eight-week periods. Assessment was made of lens fit and surface characteristics, logMAR visual acuity, ocular response and subjective reaction. RESULTS: Lens fit, deposition and post-lens debris were similar for the two lens types. High contrast visual acuity was statistically significantly better for the PureVision lens, as was the subject-reported quality of vision, although these differences were not considered clinically significant. For both lenses, limbal and conjunctival redness reduced throughout the duration of the study, whereas there was a slight increase in the overall amount of corneal staining. The incidence of mucin balls peaked four weeks after commencing lens wear and began to decline thereafter; more mucin balls were noticed in subjects wearing Focus Night &amp; Day lenses. No differences between the lenses were observed for any other biomicroscopic signs. CONCLUSIONS: This study demonstrates similar clinical performance with the two silicone hydrogel lenses evaluated. We believe that, with careful monitoring, both of these new-generation lenses can be prescribed for continuous wear

    Overlapping but disparate inflammatory and immunosuppressive responses to SARS-CoV-2 and bacterial sepsis: An immunological time course analysis

    Get PDF
    Both severe SARS-CoV-2 infections and bacterial sepsis exhibit an immunological dyscrasia and propensity for secondary infections. The nature of the immunological dyscrasias for these differing etiologies and their time course remain unclear. In this study, thirty hospitalized patients with SARS-CoV-2 infection were compared with ten critically ill patients with bacterial sepsis over 21 days, as well as ten healthy control subjects. Blood was sampled between days 1 and 21 after admission for targeted plasma biomarker analysis, cellular phenotyping, and leukocyte functional analysi
    • …
    corecore