45 research outputs found

    Microsatellite instability and intratumoural heterogeneity in 100 right-sided sporadic colon carcinomas

    Get PDF
    Microsatellite instability has been proposed as an alternative pathway of colorectal carcinogenesis. The aim of this study was to evaluate the interest of immunohistochemistry as a new tool for highlighting mismatch repair deficiency and to compare the results with a PCR-based microsatellite assay. A total of 100 sporadic proximal colon adenocarcinomas were analysed. The expression of hMLH1, hMSH2 and hMSH6 proteins evaluated by immunohistochemistry was altered in 39% of the cancers, whereas microsatellite instability assessed by PCR was detected in 43%. There was discordance between the two methods in eight cases. After further analyses performed on other tumoural areas for these eight cases, total concordance between the two techniques was observed (Kappa=100%). Our results demonstrate that immunohistochemistry may be as efficient as microsatellite amplification in the detection of unstable phenotype provided that at least two samples of each carcinoma are screened, because of intratumoural heterogeneity

    PotentialitĂ© de la spectroscopie visible & proche infrarouge couplĂ©e ou non Ă  de l’imagerie pour identifier les grains de diffĂ©rents gĂ©notypes au sein de lots de grains de 2 variĂ©tĂ©s de blĂ© dur

    No full text
    Historiquement l’expĂ©rience basĂ©e sur l’analyse de donnĂ©es spectrales collectĂ©es sur le grain tel quel nous a permis de d’infĂ©rer des traits liĂ©s Ă  la physique du grain et Ă  leur contenu biochimique. Les propriĂ©tĂ©s optiques des grains peuvent ĂȘtre utilisĂ©es pour caractĂ©riser la composition d’un mĂ©lange de grains. Dans le cas des mĂ©langes variĂ©taux, l’analyse et la comprĂ©hension de leurs performances agronomiques nĂ©cessite de disposer d’indicateurs pertinents notamment lors de l’analyse de la rĂ©colte. L’évaluation de l’aptitude des variĂ©tĂ©s au mĂ©lange nĂ©cessite donc de dĂ©velopper, outre des prĂ©dictions quantitatives des propriĂ©tĂ©s physiques et biochimiques des grains, des mĂ©thodologies permettant une caractĂ©risation rapide, non destructive et non invasive de l’importance relative de chaque composante au sein d’un mĂ©lange. Nous avons testĂ© les potentialitĂ©s de la spectromĂ©trie couplĂ©e ou non Ă  de l’imagerie pour identifier les grains de 2 gĂ©notypes au sein d’un mĂ©lange. Quelle que soit la technique utilisĂ©e, les rĂ©sultats obtenus suggĂšrent qu’une analyse discriminante basĂ©e sur des modĂšles linĂ©aires permet de discriminer les signatures spectrales gĂ©notypiques et de caractĂ©riser la proportion de chaque composante au sein du mĂ©lange. Des investigations complĂ©mentaires sont nĂ©cessaires notamment pour prĂ©ciser le domaine de validitĂ© de ces rĂ©sultats : compte tenu de la faiblesse de la base d’apprentissage (2 ans), la robustesse inter annuelle du modĂšle reste limitĂ©e et nĂ©cessite le redĂ©veloppement d’un modĂšle par expĂ©rience

    Mesure de la qualité du grain de blé dur par spectrométrie proche infrarouge

    Get PDF
    Le blĂ© dur fait l'objet de nombreux programmes d'amĂ©lioration gĂ©nĂ©tique qui, outre la sĂ©lection sur des caractĂšres agronomiques (productivitĂ©, rĂ©sistance aux maladies), portent sur l’amĂ©lioration des propriĂ©tĂ©s du grain en relation avec sa valorisation dans le processus de transformation en semoule et/ou en pĂątes. Au cours de ce processus industriel, diffĂ©rents critĂšres liĂ©s au contenu biochimique du grain (teneur en azote, couleur) ou Ă  ses propriĂ©tĂ©s physiques (taille, masse volumique, taux de mitadin) sont pris en considĂ©ration. Le coĂ»t des analyses nĂ©cessaires, leur caractĂšre destructif, la diversitĂ© des appareillages nĂ©cessaires font qu’il n’est pas rĂ©aliste de mesurer l’ensemble de ces paramĂštres sur un trĂšs grand nombre de gĂ©notypes comme cela est classiquement le cas dans les programmes de sĂ©lection. La spectromĂ©trie proche infrarouge (en anglais NIRS: Near InfraRed Spectroscopy) a Ă©tĂ© utilisĂ©e afin de dĂ©velopper une mĂ©thode rapide et non destructive, directement sur les grains entiers. Les spectres obtenus par rĂ©flectance ont Ă©tĂ© collectĂ©s dans les zones du visible et du proche infrarouge (400-2500nm). En parallĂšle, des mesures ont Ă©tĂ© rĂ©alisĂ©es au laboratoire en suivant les mĂ©thodes chimiomĂ©triques normalisĂ©es permettant de construire des modĂšles statistiques. Les calibrations/ validations obtenues permettent de correctement prĂ©dire la teneur en protĂ©ines, le taux de mitadin, le rendement semoulier (RÂČ > 0.85). Les calibrations pour le poids de 1000 grains et l’indice de jaune ont des rĂ©sultats lĂ©gĂšrement infĂ©rieurs (0.68 < RÂČ < 0.80)

    PotentialitĂ© de la spectroscopie visible & proche infrarouge couplĂ©e ou non Ă  de l’imagerie pour identifier les grains de diffĂ©rents gĂ©notypes au sein de lots de grains de 2 variĂ©tĂ©s de blĂ© dur

    No full text
    National audienceHistoriquement l’expĂ©rience basĂ©e sur l’analyse de donnĂ©es spectrales collectĂ©es sur le grain tel quel nous a permis de d’infĂ©rer des traits liĂ©s Ă  la physique du grain et Ă  leur contenu biochimique. Les propriĂ©tĂ©s optiques des grains peuvent ĂȘtre utilisĂ©es pour caractĂ©riser la composition d’un mĂ©lange de grains. Dans le cas des mĂ©langes variĂ©taux, l’analyse et la comprĂ©hension de leurs performances agronomiques nĂ©cessite de disposer d’indicateurs pertinents notamment lors de l’analyse de la rĂ©colte. L’évaluation de l’aptitude des variĂ©tĂ©s au mĂ©lange nĂ©cessite donc de dĂ©velopper, outre des prĂ©dictions quantitatives des propriĂ©tĂ©s physiques et biochimiques des grains, des mĂ©thodologies permettant une caractĂ©risation rapide, non destructive et non invasive de l’importance relative de chaque composante au sein d’un mĂ©lange. Nous avons testĂ© les potentialitĂ©s de la spectromĂ©trie couplĂ©e ou non Ă  de l’imagerie pour identifier les grains de 2 gĂ©notypes au sein d’un mĂ©lange. Quelle que soit la technique utilisĂ©e, les rĂ©sultats obtenus suggĂšrent qu’une analyse discriminante basĂ©e sur des modĂšles linĂ©aires permet de discriminer les signatures spectrales gĂ©notypiques et de caractĂ©riser la proportion de chaque composante au sein du mĂ©lange. Des investigations complĂ©mentaires sont nĂ©cessaires notamment pour prĂ©ciser le domaine de validitĂ© de ces rĂ©sultats : compte tenu de la faiblesse de la base d’apprentissage (2 ans), la robustesse inter annuelle du modĂšle reste limitĂ©e et nĂ©cessite le redĂ©veloppement d’un modĂšle par expĂ©rience

    Assessing leaf nitrogen content and leaf mass per unit area of wheat in the field throughout plant cycle with a portable spectrometer

    No full text
    Leaf nitrogen content (LNC) and leaf mass per unit area (LMA) were assessed by near-infrared spectroscopy (NIRS) on fresh and dried plants of durum wheat (Triticum turgidum ssp). Individual leaves were scanned with a portable spectrometer and reference analyses of LNC and LMA were then carried out. Partial least squares (PLS) regression was used for calibration and cross-validation. INC was accurately predicted for both fresh and dry leaves whatever the phenologic stage (correlation coefficient of calibration R(2)cal ranging from 0.932 to 0.958, standard error of cross-validation SECV ranging from 0.215 to 0.320% (dry matter)). LMA was predicted with R(2)cal = 0.942 and SECV = 4.84g m(-2). The combination of these two calibrations made it possible to predict leaf nitrogen per unit area (R(2)cross-validation = 0.94, SECV = 0.248 gN m(-2)) and provides a relevant and non-destructive tool for following the dynamics of three major leaf parameters

    Rapid phenotyping of the tomato fruit model, Micro-Tom, with a portable VISeNIR spectrometer

    Get PDF
    International audienceTomato (Solanum lycopersicum) quality traits such as juice soluble solid content (Brix), juice pH, color parameters (Hue and Chroma), firmness and water content, are critical factors for fruit quality assessment. The need for screening very large numbers of fruit has led to the development of a highthroughput method using visibleenear infrared (VISeNIR) spectrometry. We are reporting here a set of results obtained with a portable spectrometer using the 350e2500 nm range, showing good prediction of the quality traits cited above, over a wide range of developmental stages from immature green to ripe tomato fruit, cv. Micro-Tom. This is a rather good set of quality traits compared to previous publications predicting tomato quality with VIS-NIR spectrometry, and the prediction is robust, as it was obtained by grouping sets of different operators. This would be a useful tool to phenotype hundreds of Micro-Tom per day, making it possible to follow the dynamics of the described parameters on growing fruits. Thus the method can be used to study the biochemistry and physiology of fruit development in planta
    corecore