46 research outputs found

    Intelligent integration of BIPV and load management systems for modern buildings

    Get PDF
    This paper outlines the basics of load management, and highlights the possibility of maximising the contribution from the Building Integrated Photovoltaic (BIPV) power generation. It will also explain the underlying principles of a dynamic modelling approach and its application in supporting the anticipatory control strategy for load shifting. For many types of building applications, the load profiles are well matched with the BIPV generation profiles such that the BIPV power source is already acting as the peak clipping device. The application of Building Management Systems (BMS) in load shifting should consider the supply from BIPV system. Secondly, due to the thermal mass of the building, there exists time delay in the response of the power requirement of the HVAC system in the building from the solar radiation data. The BIPV system, on the contrary, is responding almost instantaneously to the solar irradiance. A dynamic BIPV model could be applied in aiding the prediction of the load profile. This paper will outline these aspects of the BIPV system as a demonstration of its application in BMS.postprintThe 8th Annual Power Symposium, Hong Kong, 19 June 2009

    Integration of BIPV systems and load management

    Get PDF
    This paper outlines the basics of load management, and highlights the possibility of maximising the contribution from the Building Integrated Photovoltaic (BIPV) power generation. It will also explain the underlying principles of a dynamic modelling approach and its application in supporting the anticipatory control strategy for load shifting. For many types of building applications, the load profiles are well matched with the BIPV generation profiles such that the BIPV power source is already acting as the peak clipping device. The application of Building Management Systems (BMS) in load shifting should consider the supply from BIPV system. Secondly, due to the thermal mass of the building, there exists time delay in the response of the power requirement of the HVAC system in the building from the solar radiation data. The BIPV system, on the contrary, is responding almost instantaneously to the solar irradiance. A dynamic BIPV model could be applied in aiding the prediction of the load profile. This paper will outline these aspects of the dynamic model developed as a demonstration of its application.postprintThe International Conference on Electrical Engineering 2009

    Influence of drying treatments on antioxidant capacity of forage legume leaves

    Get PDF
    This study was aimed to investigate the antioxidant capacities of four common forage legume leaves namely, Arachis pintoi (Pintoi), Calapogonium mucunoides (Calapo), Centrosema pubescens (Centro), and Stylosanthes guanensis (Stylo). Two different drying methods (oven-drying and freeze-drying) were employed and antioxidant activities were determined by DPPH, Ferric Reducing Antioxidant Power (FRAP) and β-carotene bleaching assays. Total phenolic content (TPC) was determined using Folin-Ciocalteu assay. Freeze-dried extract showed the highest antioxidant activities by DPPH (EC50 values 1.17–2.13 mg/ml), FRAP (147.08–246.42 μM of Fe2+/g), and β-carotene bleaching (57.11–78.60%) compared to oven drying. Hence, freeze drying treatment could be considered useful in retention of antioxidant activity and phenolic content

    Uncovering the effect of low-frequency static magnetic field on tendon-derived cells: from mechanosensing to tenogenesis

    Get PDF
    Magnetotherapy has been receiving increased attention as an attractive strategy for modulating cell physiology directly at the site of injury, thereby providing the medical community with a safe and non- invasive therapy. Yet, how magnetic eld in uences tendon cells both at the cellular and molecular levels remains unclear. Thus, the in uence of a low-frequency static magnetic eld (2 Hz, 350 mT) on human tendon-derived cells was studied using di erent exposure times (4 and 8 h; short-term studies) and di erent regimens of exposure to an 8h-period of magnetic stimulation (continuous, every 24 h or every 48 h; long-term studies). Herein, 8 h stimulation in short-term studies signi cantly upregulated the expression of tendon-associated genes SCX, COL1A1, TNC and DCN (p < 0.05) and altered intracellular Ca2+ levels (p < 0.05). Additionally, every 24 h regimen of stimulation signi cantly upregulated COL1A1, COL3A1 and TNC at day 14 in comparison to control (p < 0.05), whereas continuous exposure di erentially regulated the release of the immunomodulatory cytokines IL-1β and IL-10 (p < 0.001) but only at day 7 in comparison to controls. Altogether, these results provide new insights on how low-frequency static magnetic eld ne-tune the behaviour of tendon cells according to the magnetic settings used, which we foresee to represent an interesting candidate to guide tendon regeneration.info:eu-repo/semantics/publishedVersio

    Linguistic validation, validity and reliability of the British English versions of the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire and QuickDASH in people with rheumatoid arthritis

    Get PDF
    Background: Although the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire is widely used in the UK, no British English version is available. The aim of this study was to linguistically validate the DASH into British English and then test the reliability and validity of the British English DASH, (including the Work and Sport/Music DASH) and QuickDASH, in people with rheumatoid arthritis (RA). Methods: The DASH was forward translated, reviewed by an expert panel and cognitive debriefing interviews undertaken with 31 people with RA. Content validity was evaluated using the ICF Core Set for RA. Participants with RA (n=340) then completed the DASH, Health Assessment Questionnaire (HAQ), Short Form Health Survey v2 (SF36v2) and Measure of Activity Performance of the Hand (MAPHAND). We examined internal consistency and concurrent validity for the DASH, Work and Sport/Music DASH modules and QuickDASH. Participants repeated the DASH to assess test-retest reliability. Results: Minor wording changes were made as required. The DASH addresses a quarter of Body Function and half of Activities and Participation codes in the ICF RA Core Set. Internal consistency for DASH scales were consistent with individual use (Cronbach’s alpha = 0.94-0.98). Concurrent validity was strong with the HAQ (rs = 0.69-0.91), SF36v2 Physical Function (rs = -0.71 - -0.85), Bodily Pain (rs = -0.71 - -0.74) scales and MAPHAND (rs =0.71-0.93). Test-retest reliability was good (rs = 0.74-0.95). Conclusions: British English versions of the DASH, QuickDASH and Work and Sport/Music modules are now available to evaluate upper limb disabilities in the UK. The DASH, QuickDASH, Work and Sport/Music modules are reliable and valid to use in clinical practice and research with British people with RA

    The voltage control problem with the variation of the renewable power generation and load demand

    No full text
    Conference Theme: Future Technology for Bridging NationsVoltage stability issues can be classified into three main types: static voltage instability, dynamic voltage instability and transient voltage instability. This paper will focus on the voltage control which is an important element in the static voltage stability problem. Under given configuration and condition of the power grid, the power supply and customer demand are the two main aspects which significantly influence the operation status of the power grid. Thus, two operational scenarios of the power grid in practice which are corresponding to the variation of the power generation and load demand respectively have been selected for discussion: the voltage drop that is caused by the intermittent renewable power connection; and the increase of the load demand resulting in voltage sag. The former will be analyzed with renewable power generations connected to a specific power network to investigate the voltage deviation of the nodes and work out some corresponding solutions to improve the voltage performance. The second part will examine the situation in which the increases of the loads resulting in the drop of the bus voltages at the load side and apply the some devices to control the voltage deviation in a certain range automatically and dynamically. Corresponding to each individual problem, this paper will establish different models and apply effective methods to simulate the related solutions in order to improve the voltage performance, which can provide us with referable information in the stable operation of the power system.The 2016 The International Conference on Electrical Engineering (ICEE 2016), Okinawa, Japan, 3-7 July 2016
    corecore