    Visualization of postoperative anterior cruciate ligament reconstruction bone tunnels: Reliability of standard radiographs, CT scans, and 3D virtual reality images

    Get PDF
    Background and purpose: Non-anatomic bone tunnel placement is the most common cause of a failed ACL reconstruction. Accurate and reproducible methods to visualize and document bone tunnel placement are therefore important. We evaluated the reliability of standard radiographs, CT scans, and a 3-dimensional (3D) virtual reality (VR) approach in visualizing and measuring ACL reconstruction bone tunnel placement. Methods: 50 consecutive patients who underwent single-bundle ACL reconstructions were evaluated postoperatively by standard radiographs, CT scans, and 3D VR images. Tibial and femoral tunnel positions were measured by 2 observers using the traditional methods of Amis, Aglietti, Hoser, Stubli, and the method of Benereau for the VR approach. Results: The tunnel was visualized in 50-82% of the standard radiographs and in 100% of the CT scans and 3D VR images. Using the intraclass correlation coefficient (ICC), the inter- and intraobserver agreement was between 0.39 and 0.83 for the standard femoral and tibial radiographs. CT scans showed an ICC range of 0.49-0.76 for the inter- and intraobserver agreement. The agreement in 3D VR was almost perfect, with an ICC of 0.83 for the femur and 0.95 for the tibia. Interpretation: CT scans and 3D VR images are more reliable in assessing postoperative bone tunnel placement following ACL reconstruction than standard radiographs. Copyright

    Tomographic renal cortical scintigraphy: Correlation with intravenous urography, computed tomography, ultrasonography, angiography, and nuclear magnetic resonance imaging

    Full text link
    This study evaluates single-photon renal tomoscintigraphy (SPECT) in the evaluation of renal masses and correlates this modality, where indicated, with computed tomography (CT), ultrasonography (US), angiography (ANGIO) and nuclear magnetic resonance imaging (NMR). Eight patients with renal cortical lesions detected on intravenous urography (IVP) were evaluated by SPECT and planar nuclear imaging using Tc-99m glucoheptonate (GH). Three of these patients were felt particularly likely to have renal tumors and were additionally evaluated with US, CT, ANGIO and NMR. The five patients with nodules on IVP that were not particularly suggestive of malignancy had functioning, benign, renal tissue accounting for their IVP lesions. Four of five were found by planar-GH nuclear imaging, five/five by SPECT-GH. In addition, SPECT-GH allowed better “confidence” in the normal renal tissue diagnosis in three/five cases. Of the three renal lesions that were highly suggestive of malignancy, two were hypernephromas and one was hypertrophied functioning cortical tissue. All three were correctly identified prospectively on SPECT-GH; however, one hypernephroma was missed on planar-GH. NMR, CT, and ANGIO detected only one of two hypernephromas prospectively (US detected both); all four modalities incorrectly diagnosed the hypertrophied tissue suggestive of malignancy.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/46822/1/259_2004_Article_BF00279072.pd

    Radiological informed consent in cardiovascular imaging: towards the medico-legal perfect storm?

    Get PDF
    Use of radiation for medical examinations and tests is the largest manmade source of radiation exposure. No one can doubt the immense clinical and scientific benefits of imaging to the modern practice of medicine. Every radiological and nuclear medicine examination confers a definite (albeit low) long-term risk of cancer, but patients undergoing such examinations often receive no or inaccurate information about radiological dose exposure and corresponding risk directly related to the radiological dose received. Too detailed information on radiological dose and risk may result in undue anxiety, but information "economical with the truth" may violate basic patients' rights well embedded in ethics (Oviedo convention 1997) and law (97/43 Euratom Directive 1997). Informed consent is a procedure needed to establish a respectful and ethical relation between doctors and patients. Nevertheless, in an "ideal" consent process, the principle of patient autonomy in current radiological practice might be reinforced by making it mandatory to obtain explicit and transparent informed consent form for radiological examination with high exposure (≥ 500 chest x-rays). The form may spell-out the type of examination, the exposure in effective dose (mSv), derived from reference values in guidelines or – better – from actual values from their department. The dose equivalent might be also expressed in number of chest radiographs and the risk of cancer as number of extra cases in the exposed population, derived from most recent and authorative guidelines (e.g., BEIR VII Committee, release 2006). Common sense, deontological code, patients'rights, medical imaging guidelines, Euratom law, all coherently and concordantly encourage and recommend a justified, optimized, responsible and informed use of testing with ionizing radiation. Although the idea of informed consent for radiation dose does not seem to be on the immediate radar screen at least in the US, the current practice clashes against these guidelines and laws

    Criteria for the selective use of chest computed tomography in blunt trauma patients

    Get PDF
    Item does not contain fulltextPURPOSE: The purpose of this study was to derive parameters that predict which high-energy blunt trauma patients should undergo computed tomography (CT) for detection of chest injury. METHODS: This observational study prospectively included consecutive patients (>or=16 years old) who underwent multidetector CT of the chest after a high-energy mechanism of blunt trauma in one trauma centre. RESULTS: We included 1,047 patients (median age, 37; 70% male), of whom 508 had chest injuries identified by CT. Using logistic regression, we identified nine predictors of chest injury presence on CT (age >or=55 years, abnormal chest physical examination, altered sensorium, abnormal thoracic spine physical examination, abnormal chest conventional radiography (CR), abnormal thoracic spine CR, abnormal pelvic CR or abdominal ultrasound, base excess or=1 positive predictors, 484 had injury on CT (95% of all 508 patients with injury). Of all 192 patients with no positive predictor, 24 (13%) had chest injury, of whom 4 (2%) had injuries that were considered clinically relevant. CONCLUSION: Omission of CT in patients without any positive predictor could reduce imaging frequency by 18%, while most clinically relevant chest injuries remain adequately detected.1 april 201

    Rotational knee laxity: Reliability of a simple measurement device in vivo

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Double bundle ACL reconstruction has been demonstrated to decrease rotational knee laxity. However, there is no simple, commercially-available device to measure knee rotation. The investigators developed a simple, non-invasive device to measure knee rotation. In conjunction with a rigid boot to rotate the tibia and a force/moment sensor to allow precise determination of torque about the knee, a magnetic tracking system measures the axial rotation of the tibia with respect to the femur. This device has been shown to have acceptable levels of test re-test reliability to measure knee rotation in cadaveric knees.</p> <p>Methods</p> <p>The objective of this study was to determine reliability of the device in measuring knee rotation of human subjects. Specifically, the intra-tester reliability within a single testing session, test-retest reliability between two testing sessions, and inter-tester reliability were assessed for 11 male subjects with normal knees.</p> <p>Results</p> <p>The 95% confidence interval for rotation was less than 5° for intra-tester, test-retest, and inter-tester reliability, and the standard error of measurement for the differences between left and right knees was found to be less than 3°.</p> <p>Conclusion</p> <p>It was found that the knee rotation measurements obtained with this device have acceptable limits of reliability for clinical use and interpretation.</p
    corecore