70 research outputs found
Influence of reaction time and synthesis temperature on the physical properties of ZnO nanoparticles synthesized by the hydrothermal method
Influence of synthesis temperature and reaction time on the structural and optical properties of ZnO nanoparticles synthesized by the hydrothermal method was investigated using X-ray diffraction (XRD), high resolution transmission electron microscopy (HR-TEM), energy-dispersive X-ray, Fourier transform infra-red spectroscopy, and UV–visible and fluorescence spectroscopy. The XRD pattern and HR-TEM images confirmed the presence of crystalline hexagonal wurtzite ZnO nanoparticles with average crystallite size in the range 30–40 nm. Their energy gap determined by fluorescence was found to depend on the synthesis temperature and reaction time with values in the range 2.90–3.78 eV. Thermal analysis, thermogravimetric and the differential scanning calorimetry were used to study the thermal reactions and weight loss with heat of the prepared ZnO nanoparticles
Preparation and thermal analysis kinetics of the core–nanoshell composite materials doped with Sm
Mammographic density does not correlate with Ki-67 expression or cytomorphology in benign breast cells obtained by random periareolar fine needle aspiration from women at high risk for breast cancer
BACKGROUND:Ki-67 expression is a possible risk biomarker and is currently being used as a response biomarker in chemoprevention trials. Mammographic breast density is a risk biomarker and is also being used as a response biomarker. We previously showed that Ki-67 expression is higher in specimens of benign breast cells exhibiting cytologic atypia that are obtained by random periareolar fine needle aspiration (RPFNA). It is not known whether there is a correlation between mammographic density and Ki-67 expression in benign breast ductal cells obtained by RPFNA.METHODS:Included in the study were 344 women at high risk for developing breast cancer (based on personal or family history), seen at The University of Kansas Medical Center high-risk breast clinic, who underwent RPFNA with cytomorphology and Ki-67 assessment plus a mammogram. Mammographic breast density was assessed using the Cumulus program. Categorical variables were analyzed by ?2 test, and continuous variables were analyzed by nonparametric test and linear regression.RESULTS:Forty-seven per cent of women were premenopausal and 53% were postmenopausal. The median age was 48 years, median 5-year Gail Risk was 2.2%, and median Ki-67 was 1.9%. The median mammographic breast density was 37%. Ki-67 expression increased with cytologic abnormality (atypia versus no atypia; P = 0.001) and younger age (=50 years versus >50 years; P = 0.001). Mammographic density was higher in premenopausal women (P = 0.001), those with lower body mass index (P < 0.001), and those with lower 5-year Gail risk (P = 0.001). Mammographic density exhibited no correlation with Ki-67 expression or cytomorphology.CONCLUSION:Given the lack of correlation of mammographic breast density with either cytomorphology or Ki-67 expression in RPFNA specimens, mammographic density and Ki-67 expression should be considered as potentially complementary response biomarkers in breast cancer chemoprevention trials
Epithelial atypia in biopsies performed for microcalcifications. Practical considerations about 2,833 serially sectioned surgical biopsies with a long follow-up
This study analyzes the occurrence of epithelial atypia in 2,833 serially sectioned surgical breast biopsies (SB) performed for microcalcifications (median number of blocks per SB:26) and the occurrence of subsequent cancer after an initial diagnosis of epithelial atypia (median follow-up 160 months). Epithelial atypia (flat epithelial atypia, atypical ductal hyperplasia, and lobular neoplasia) were found in 971 SB, with and without a concomitant cancer in 301 (31%) and 670 (69%) SB, respectively. Thus, isolated epithelial atypia were found in 670 out of the 2,833 SB (23%). Concomitant cancers corresponded to ductal carcinomas in situ and micro-invasive (77%), invasive ductal carcinomas not otherwise specified (15%), invasive lobular carcinomas (4%), and tubular carcinomas (4%). Fifteen out of the 443 patients with isolated epithelial atypia developed a subsequent ipsilateral (n = 14) and contralateral (n = 1) invasive cancer. The high slide rating might explain the high percentages of epithelial atypia and concomitant cancers and the low percentage of subsequent cancer after a diagnosis of epithelial atypia as a single lesion. Epithelial atypia could be more a risk marker of concomitant than subsequent cancer
Investigation of Optical and Electrical Properties of Different Compositions of As-S-Se Thin Films at Thickness 725 nm With High Precision Using a Wedge-Shaped Optical Model
Structure Analysis and Optical Parameters of Nano-scale ZnSe/Flexible Substrate Thin Film
Thermal stability and crystallization kinetics of ternary Se–Te–Sb semiconducting glassy alloys
- …
