2 research outputs found
Analisa Optimasi Dewatering dengan Variasi Koagulan pada Lumpur Limbah Aktif Menggunakan Plate and Frame Filter Press (Optimization Analysis of Dewatering with Coagulant Variation on Activated Sewage Sludge Using Plate and Frame Filter Press)
ANALISA OPTIMASI DEWATERING DENGAN VARIASI KOAGULAN PADA LUMPUR
LIMBAH AKTIF MENGGUNAKAN PLATE AND FRAME FILTER PRESS
Dina Elvia Rani’*
21030116060061
Penelitian ini bertujuan untuk mengembangkan skema proses filtrasi untuk analisa tahanan medium filter
(Rm), specific resistance to filtration (SRF), kadar air (moisture content) serta yield pada dewatering
lumpur limbah. Target yang ingin dicapai berupa optimasi jenis koagulan pada proses dewatering lumpur
limbah. Kajian dilakukan pada berbagai variabel diantaranya variabel bebas meliputi variasi koagulan
(Tawas 80 gr/lt, 100 gr/lt, 120 gr/lt dan PAC 72 gr/lt, 100 gr/lt, 128 gr/lt) dan variasi tekanan (56 kg/cm
2
,
60 kg/cm
2
, 70 kg/cm
2
). Sedangkan variabel tetap meliputi volume lumpur, volume pelarut, kecepatan dan
lama pengadukan, serta volume filtrat. Percobaan menunjukkan jenis koagulan yang optimum diperoleh
yaitu pada koagulan Poly Alumunium Chloride (PAC). Untuk analisa SRF sebesar 6,53E+09 m/kg ;
analisa Rm sebesar 6,75E+12 1/m ; analisa kadar air sebesar 69,82% ; analisa yield sebesar 20,68
kg/m
2
h.
Kata kunci : filtrasi, lumpur limbah, dewatering
ABSTRACT
OPTIMIZATION ANALYSIS OF DEWATERING WITH COAGULANT VARIATION ON
ACTIVATED SEWAGE SLUDGE USING PLATE AND FRAME FILTER PRESS
Dina Elvia Rani’*
21030116060061
This research aims to develop the filtration process scheme for the analysis of resistance associated with
the filter medium (Rm), specific resistance to filtration (SRF), moisture content and yield for sewage
sludge dewatering. The target to be achieved is optimization the type of coagulant in the sewage sludge
dewatering process. The study was conducted on various variables including coagulant various (Tawas
80 gr/lt, 100 gr/lt, 120 gr/lt and PAC 72 gr/lt, 100 gr/lt, 128 gr/lt) and pressure various (56 kg/cm
2
, 60
kg/cm
2
, 70 kg/cm
2
). The experiment showed that the optimum coagulant of the influence of Poly
Alumunium Chloride (PAC) coagulant. Value for analysis of SRF was 6,53E+09 m/kg ; analysis of Rm
was 6,75E+12 1/m ; analysis of moisture content was 69,82%; analysis of yield was 20,68 kg/m
2
h.
Keyword : filtration, sewage sludge, dewaterin