9 research outputs found

    Recycling and photodegradation processes of organic hazardous materials on polyaniline-titanium dioxide quantum dots catalyst

    No full text
    A photo-catalyst with conducting polymers doped with titanium dioxide, known as TiO2 quantum dots (TiO2 QDs), has a high efficiency for photocatalytic usage. The organic hue methyl orange was broken down in the current study using polyaniline (PANI) and polyaniline titanium dioxide quantum dots (PANI-TiO2 QDs) polymers. PANI and PANI-TiO2 QDs have been produced by chemical oxidative polymerization in an aqueous solution. By characterization of PANI-TiO2 QDs nanocomposites using ultraviolet–visible (UV–vis), Fourier transform infrared (FTIR), and X-ray powder diffraction (XRD), it was demonstrated that the chemical structure of polymer composites had not changed after being doped with TiO2 QDs. To determine the form, size, surface area, and thermal analyses of the produced PANI-TiO2 QDs samples, EDX, BET, and TGA were used. The photocatalytic activity of the PANI-TiO2 QDs in the photo-degradation of methyl orange dye as an organic hazardous chemical in an aqueous medium was assessed using a 50-watt xenon lamp light source and direct sunlight. PANI-TiO2 QDs demonstrated high photocatalytic properties, with a 93% efficiency, as opposed to 35% and 60.1%, respectively, for PANI and TiO2 QDs. When PANI, titanium dioxide quantum dots, and PANI-TiO2 QDs are present during the recycling processes in the presence of all created samples up to four times, the photo-degradation rate decreases by about 50.2%, 15.4%, and 17.4%, respectively

    Anisotropy of 4f states in 3d 4f single molecule magnets

    No full text
    We have measured angular dependent fluorescence yield x ray magnetic circular dichroism spectra on single crystals of the heterometallic 3d amp; 8722;4f 12 metallacrown 4 TbMn4 and DyMn4 complexes. Simulated spectra using crystal field multiplet calculations reproduce the experimentally observed spectra. The orientation of the molecules causes linear dichroism spectra of the 4f absorption spectra. This natural linear dichroism shows the anisotropic charge distribution of the rare earth 4f state in the tetragonal crystal field despite the small 4f crystal field splitting. The magnetic moment of the molecule is dominated by the rare earth moment revealing a considerably large contribution of orbital moment. From a sum rule analysis of experimental and simulated x ray magnetic circular dichroism, we determined corrected spin and orbital Dy moments at low temperature 14 K within a magnetic field of 7 T. We find a significant angular dependence of the Dy magnetic moments, indicating the presence of fourth order magnetic anisotrop

    Piperine: Old Spice and New Nutraceutical?

    No full text

    Accelerated surgery versus standard care in hip fracture (HIP ATTACK) : an international, randomised, controlled trial

    No full text
    Background: Observational studies have suggested that accelerated surgery is associated with improved outcomes in patients with a hip fracture. The HIP ATTACK trial assessed whether accelerated surgery could reduce mortality and major complications. Methods: HIP ATTACK was an international, randomised, controlled trial done at 69 hospitals in 17 countries. Patients with a hip fracture that required surgery and were aged 45 years or older were eligible. Research personnel randomly assigned patients (1:1) through a central computerised randomisation system using randomly varying block sizes to either accelerated surgery (goal of surgery within 6 h of diagnosis) or standard care. The coprimary outcomes were mortality and a composite of major complications (ie, mortality and non-fatal myocardial infarction, stroke, venous thromboembolism, sepsis, pneumonia, life-threatening bleeding, and major bleeding) at 90 days after randomisation. Patients, health-care providers, and study staff were aware of treatment assignment, but outcome adjudicators were masked to treatment allocation. Patients were analysed according to the intention-to-treat principle. This study is registered at ClinicalTrials.gov (NCT02027896). Findings: Between March 14, 2014, and May 24, 2019, 27 701 patients were screened, of whom 7780 were eligible. 2970 of these were enrolled and randomly assigned to receive accelerated surgery (n=1487) or standard care (n=1483). The median time from hip fracture diagnosis to surgery was 6 h (IQR 4\u20139) in the accelerated-surgery group and 24 h (10\u201342) in the standard-care group (p<0\ub70001). 140 (9%) patients assigned to accelerated surgery and 154 (10%) assigned to standard care died, with a hazard ratio (HR) of 0\ub791 (95% CI 0\ub772 to 1\ub714) and absolute risk reduction (ARR) of 1% ( 121 to 3; p=0\ub740). Major complications occurred in 321 (22%) patients assigned to accelerated surgery and 331 (22%) assigned to standard care, with an HR of 0\ub797 (0\ub783 to 1\ub713) and an ARR of 1% ( 122 to 4; p=0\ub771). Interpretation: Among patients with a hip fracture, accelerated surgery did not significantly lower the risk of mortality or a composite of major complications compared with standard care. Funding: Canadian Institutes of Health Research
    corecore