2,173 research outputs found
Indigenous and institutional profile: Limpopo River Basin
River basins / Water resource management / History / Institutions / Social aspects / Legal aspects
Homotopy types of stabilizers and orbits of Morse functions on surfaces
Let be a smooth compact surface, orientable or not, with boundary or
without it, either the real line or the circle , and
the group of diffeomorphisms of acting on by the rule
, where and .
Let be a Morse function and be the orbit of under this
action. We prove that for , and
except for few cases. In particular, is aspherical, provided so is .
Moreover, is an extension of a finitely generated free abelian
group with a (finite) subgroup of the group of automorphisms of the Reeb graph
of .
We also give a complete proof of the fact that the orbit is tame
Frechet submanifold of of finite codimension, and that the
projection is a principal locally trivial -fibration.Comment: 49 pages, 8 figures. This version includes the proof of the fact that
the orbits of a finite codimension of tame action of tame Lie group on tame
Frechet manifold is a tame Frechet manifold itsel
Multipurpose High Frequency Electron Spin Resonance Spectrometer for Condensed Matter Research
We describe a quasi-optical multifrequency ESR spectrometer operating in the
75-225 GHz range and optimized at 210 GHz for general use in condensed matter
physics, chemistry and biology. The quasi-optical bridge detects the change of
mm wave polarization at the ESR. A controllable reference arm maintains a mm
wave bias at the detector. The attained sensitivity of 2x10^10 spin/G/(Hz)1/2,
measured on a dilute Mn:MgO sample in a non-resonant probe head at 222.4 GHz
and 300 K, is comparable to commercial high sensitive X band spectrometers. The
spectrometer has a Fabry-Perot resonator based probe head to measure aqueous
solutions, and a probe head to measure magnetic field angular dependence of
single crystals. The spectrometer is robust and easy to use and may be operated
by undergraduate students. Its performance is demonstrated by examples from
various fields of condensed matter physics.Comment: submitted to Journal of Magnetic Resonanc
Recommended from our members
Acrylic vessel cleaning tests
The acrylic vessel as constructed is dirty. The dirt includes blue tape, Al tape, grease pencil, gemak, the glue or residue form these tapes, finger prints and dust of an unknown composition but probably mostly acrylic dust. This dirt has to be removed and once removed, the vessel has to be kept clean or at least to be easily cleanable at some future stage when access becomes much more difficult. The authors report on the results of a series of tests designed: (a) to prepare typical dirty samples of acrylic; (b) to remove dirt stuck to the acrylic surface; and (c) to measure the optical quality and Th concentration after cleaning. Specifications of the vessel call for very low levels of Th which could come from tape residues, the grease pencil, or other sources of dirt. This report does not address the concerns of how to keep the vessel clean after an initial cleaning and during the removal of the scaffolding. Alconox is recommended as the cleaner of choice. This acrylic vessel will be used in the Sudbury Neutrino Observatory
The Gridded Retarding Ion Drift Sensor for the PetitSat CubeSat Mission
The Gridded Retarding Ion Drift Sensor (GRIDS) is a small sensor that will fly on the 6 U petitSat CubeSat. It is designed to measure the three-dimensional plasma drift velocity vector in the Earth’s ionosphere. The GRIDS also supplies information about the ion temperature, ion density, and the ratio of light to heavy ions present in the ionospheric plasma. It utilizes well-proven techniques that have been successfully validated by similar instruments on larger satellite missions while meeting CubeSat-compatible requirements for low mass, size, and power consumption. GRIDS performs the functions of a Retarding Potential Analyzer (RPA) and an Ion Drift Meter (IDM) by combining the features of both types of instruments in a single package. The sensor alternates RPA and IDM measurements to produce the full set of measurement parameters listed above. On the petitSat mission, GRIDS will help identify and characterize a phenomenon known as plasma blobs (or enhancements)
Evaluation of the WMO Solid Precipitation Intercomparison Experiment (SPICE) transfer functions for adjusting the wind bias in solid precipitation measurements
The World Meteorological Organization (WMO) Solid Precipitation Intercomparison Experiment (SPICE) involved extensive field intercomparisons of automated instruments for measuring snow during the 2013/2014 and 2014/2015 winter seasons. A key outcome of SPICE was the development of transfer functions for the wind bias adjustment of solid precipitation measurements using various precipitation gauge and wind shield configurations. Due to the short intercomparison period, the data set was not sufficiently large to develop and evaluate transfer functions using independent precipitation measurements, although on average the adjustments were effective at reducing the bias in unshielded gauges from −33.4 % to 1.1 %. The present analysis uses data collected at eight SPICE sites over the 2015/2016 and 2016/2017 winter periods, comparing 30 min adjusted and unadjusted measurements from Geonor T-200B3 and OTT Pluvio2 precipitation gauges in different shield configurations to the WMO Double Fence Automated Reference (DFAR) for the evaluation of the transfer function. Performance is assessed in terms of relative total catch (RTC), root mean square error (RMSE), Pearson correlation (r), and percentage of events (PEs) within 0.1 mm of the DFAR. Metrics are reported for combined precipitation types and for snow only. The evaluation shows that the performance varies substantially by site. Adjusted RTC varies from 54 % to 123 %, RMSE from 0.07 to 0.38 mm, r from 0.28 to 0.94, and PEs from 37 % to 84 %, depending on precipitation phase, site, and gauge configuration (gauge and wind screen type). Generally, windier sites, such as Haukeliseter (Norway) and Bratt's Lake (Canada), exhibit a net under-adjustment (RTC of 54 % to 83 %), while the less windy sites, such as Sodankylä (Finland) and Caribou Creek (Canada), exhibit a net over-adjustment (RTC of 102 % to 123 %). Although the application of transfer functions is necessary to mitigate wind bias in solid precipitation measurements, especially at windy sites and for unshielded gauges, the variability in the performance metrics among sites suggests that the functions be applied with caution
Assessment of snowfall accumulation underestimation by tipping bucket gauges in the Spanish operational network
Within the framework of the World Meteorological Organization Solid Precipitation Intercomparison Experiment (WMO-SPICE), the Thies tipping bucket precipitation gauge was assessed against the SPICE reference configuration at the Formigal–Sarrios test site located in the Pyrenees mountain range of Spain. The Thies gauge is the most widely used precipitation gauge by the Spanish Meteorological State Agency (AEMET) for the measurement of all precipitation types including snow. It is therefore critical that its performance is characterized. The first objective of this study is to derive transfer functions based on the relationships between catch ratio and wind speed and temperature. Multiple linear regression was applied to 1 and 3 h accumulation periods, confirming that wind is the most dominant environmental variable affecting the gauge catch efficiency, especially during snowfall events. At wind speeds of 1.5 m s−1 the tipping bucket recorded only 70 % of the reference precipitation. At 3 m s−1, the amount of measured precipitation decreased to 50 % of the reference, was even lower for temperatures colder than −2 °C and decreased to 20 % or less for higher wind speeds
Aging in a topological spin glass
We have examined the nonconventional spin glass phase of the 2-dimensional
kagome antiferromagnet (H_3 O) Fe_3 (SO_4)_2 (OH)_6 by means of ac and dc
magnetic measurements. The frequency dependence of the ac susceptibility peak
is characteristic of a critical slowing down at Tg ~ 18K. At fixed temperature
below Tg, aging effects are found which obey the same scaling law as in spin
glasses or polymers. However, in clear contrast with conventional spin glasses,
aging is remarkably insensitive to temperature changes. This particular type of
dynamics is discussed in relation with theoretical predictions for highly
frustrated non-disordered systems.Comment: 4 pages, 4 figure
- …