23 research outputs found

    Initial experience of the BREAST-Q breast-conserving therapy module.

    Get PDF
    Purpose The most recently developed module of the BREAST-Q, a validated patient outcome measure, is for patients who have undergone breast-conserving therapy (BCT) for cancer. This aim of this study was to assess patient satisfaction and quality of life after BCT using BREAST-Q, investigate clinical risk factors for lower satisfaction and explore the relationship between patient satisfaction with the appearance of their breasts and the other domains of the BREAST-Q.Methods Women who had undergone unilateral BCT in the preceding 1-6 years were invited to participate at the time of their annual surveillance mammogram. Clinicopathological data were collected from an electronic database. Linear regression was used to evaluate risk factors for lower satisfaction. Spearman's rho correlation coefficients were calculated to evaluate the relationship between domains.Results 200 women completed the questionnaire. Mean age was 60 years (SD 11.1). Time from surgery was 35.5 months (SD 17.8). Median score for 'Satisfaction with breasts' was 68 (interquartile range 55-80). Lowest scores were for 'sexual wellbeing' (57, IQR 45-66). On multivariate analysis, BMI at the time of surgery (p = 0.002), delayed wound healing (p = 0.001) and axillary surgery (p = 0.003) were independent risk factors for lower satisfaction. There was significant correlation between 'Satisfaction with breasts' and all other BREAST-Q domains.Conclusion High BMI, delayed wound healing and axillary surgery are risk factors for lower patient satisfaction. This first publication reporting the whole dataset for the BREAST-Q BCT will serve as a benchmark for future studies of patient satisfaction following BCT

    Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach.</p> <p>Methods</p> <p>A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009.</p> <p>Results</p> <p>Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P < 0.001) patients in the spring-loaded 14-gauge core biopsy group (81/719, 11.3%) than in the 8-gauge vacuum-assisted biopsy group (18/724, 2.5%) were recommended for further diagnostic surgical removal of additional tissue from the same anatomical site of the affected breast in an immediate fashion for indeterminate/inconclusive findings seen on the original ultrasound-guided diagnostic breast biopsy procedure. Significantly more (P < 0.001) patients in the spring-loaded 14-gauge core biopsy group (54/719, 7.5%) than in the 8-gauge vacuum-assisted biopsy group (9/724, 1.2%) personally requested further diagnostic surgical removal of additional tissue from the same anatomical site of the affected breast in an immediate fashion for a benign finding seen on the original ultrasound-guided diagnostic breast biopsy procedure.</p> <p>Conclusions</p> <p>In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information.</p

    Three horizontal muscle surgery for large-angle infantile esotropia: Validation of a table of amounts of surgery

    No full text
    PurposeTo validate a table of amounts of three horizontal muscle surgery in patients with large-angle infantile esotropia (60 prism dioptres, PD).MethodsA prospective interventional case series reporting the postoperative alignment of 51 patients (27 male, 24 female) over a 15-year period was conducted. Surgery amounts were according to a published table developed on a previous patient cohort (n=49), using bilateral medial rectus recession with graded unilateral lateral rectus resection. Kaplan-Meier life-table survival curves were formulated for success to orthotropia (±10 PD) after one and subsequent horizontal muscle surgeries for up to 8 years follow-up.ResultsThe median preoperative deviation was 65 PD (range 60-80 PD) and median age at surgery was 11.8 months (range 5.1 months-3.6 years). Surgical success to orthotropia (±10 PD) after one surgery was 100% at 2 months, 95.7% at 6 months, 91.3% at 12 months, 77.8% at 4 years, and 73.6% at 8 years. Postoperative failure requiring further horizontal surgery occurred in 17.6% (residual esotropia 4, consecutive exotropia 5).ConclusionsOur second cohort has reproduced the success rate of the previous cohort (77.8% vs 77.1% at 4 years). If the published table of surgical amounts is used, three horizontal muscle surgery in large-angle infantile esotropia (≥60 PD) appears to have a good long-term success rate, and does not lead to the high rates of either residual esotropia or consecutive exotropia reported by others in the literature
    corecore