758 research outputs found

    Few promising multivariable prognostic models exist for recovery of people with non-specific neck pain in musculoskeletal primary care: a systematic review

    Get PDF
    © 2017 Australian Physiotherapy Association Question Which multivariable prognostic model(s) for recovery in people with neck pain can be used in primary care? Design Systematic review of studies evaluating multivariable prognostic models. Participants People with non-specific neck pain presenting at primary care. Determinants Baseline characteristics of the participants. Outcome measures Recovery measured as pain reduction, reduced disability, or perceived recovery at short-term and long-term follow-up. Results Fifty-three publications were included, of which 46 were derivation studies, four were validation studies, and three concerned combined studies. The derivation studies presented 99 multivariate models, all of which were at high risk of bias. Three externally validated models generated usable models in low risk of bias studies. One predicted recovery in non-specific neck pain, while two concerned participants with whiplash-associated disorders (WAD). Discriminative ability of the non-specific neck pain model was area under the curve (AUC) 0.65 (95% CI 0.59 to 0.71). For the first WAD model, discriminative ability was AUC 0.85 (95% CI 0.79 to 0.91). For the second WAD model, specificity was 99% (95% CI 93 to 100) and sensitivity was 44% (95% CI 23 to 65) for prediction of non-recovery, and 86% (95% CI 73 to 94) and 55% (95% CI 41 to 69) for prediction of recovery, respectively. Initial Neck Disability Index scores and age were identified as consistent prognostic factors in these three models. Conclusion Three externally validated models were found to be usable and to have low risk of bias, of which two showed acceptable discriminative properties for predicting recovery in people with neck pain. These three models need further validation and evaluation of their clinical impact before their broad clinical use can be advocated. Registration PROSPERO CRD42016042204. [Wingbermühle RW, van Trijffel E, Nelissen PM, Koes B, Verhagen AP (2018) Few promising multivariable prognostic models exist for recovery of people with non-specific neck pain in musculoskeletal primary care: a systematic review. Journal of Physiotherapy 64: 16–23

    Environmental Particle Emissions due to Automated Drilling of Polypropylene Composites and Nanocomposites Reinforced with Talc, Montmorillonite and Wollastonite

    Get PDF
    In this study, the effect on nanoparticle emissions due to drilling on Polypropylene (PP) reinforced with 20% talc, 5% montmorillonite (MMT) and 5% Wollastonite (WO) is investigated. The study is the first to explore the nanoparticle release from WO and talc reinforced composites and compares the results to previously researched MMT. With 5% WO, equivalent tensile properties with a 10 % weight reduction were obtained relative to the reference 20% talc sample. The materials were fabricated through injection moulding. The nanorelease studies were undertaken using the controlled drilling methodology for nanoparticle exposure assessment developed within the European Commission funded SIRENA Life 11 ENV/ES/506 project. Measurements were taken using CPC and DMS50 equipment for real-time characterization and measurements. The particle number concentration (of particles <1000nm) and particle size distribution (4.87nm - 562.34nm) of the particles emitted during drilling were evaluated to investigate the effect of the silicate fillers on the particles released. The nano-filled samples exhibited a 33% decrease (MMT sample) or a 30% increase (WO sample) on the average particle number concentration released in comparison to the neat polypropylene sample. The size distribution data displayed a substantial percentage of the particles released from the PP, PP/WO and PP/MMT samples to be between 5-20nm, whereas the PP/talc sample emitted larger particle diameters.The work is funded by and part of the European Commission Life project named Simulation of the release of nanomaterials from consumer products for environmental exposure assessment (SIRENA, Pr. No. LIFE 11 ENV/ES/596). The access and use of the facilities at the Flemish Institute for Technological Research (VITO) was funded by QualityNano Project through Transnational Access (TA Application VITO-TAF-382 and VITO-TAF-500) under the European Commission, Grant Agreement No: INFRA-2010-262163. Kristof is also thankful for partial funding by the School of Engineering at Robert Gordon University for his studentship

    Association between weight or Body Mass Index and hand osteoarthritis: a systematic review

    Get PDF
    Objective: To investigate the association between weight or Body Mass Index (BMI) and the development of hand osteoarthritis (OA). Methods: Systematic review of observational studies. Medical databases were searched up to April 2008. Articles which presented data on the association between weight and hand OA were selected. The qualities of these studies were then assessed by two independent reviewers using a 19 criteria scoring syst

    Outcome in hip fracture patients related to anemia at admission and allogeneic blood transfusion: an analysis of 1262 surgically treated patients

    Get PDF
    Background: Anemia is more often seen in older patients. As the mean age of hip fracture patients is rising, anemia is common in this population. Allogeneic blood transfusion (ABT) and anemia have been pointed out as possible risk factors for poorer outcome in hip fracture patients. Methods. In the timeframe 2005-2010, 1262 admissions for surgical treatment of a hip fracture in patients aged 65 years and older were recorded. Registration was prospective from 2008 on. Anemic and non-anemic patients (based on hemoglobin level at admission) were compared regarding clinical characteristics, mortality, delirium incidence, LOS, discharge to a nursing home and the 90-day readmission rate. Receiving an ABT, age, gender, ASA classification, type of fracture and anesthesia were used as possible confounders in multivariable regression analysis. Results: The prevalence of anemia and the rate of ABT both were 42.5%. Anemic patients were more likely to be older and men and had more often a trochanteric fracture, a higher ASA score and received more often an ABT. In univariate analysis, the 3- and 12-month mortality rate, delirium incidence and discharge to a nursing home rate were significantly worse in preoperatively anemic patients. In multivariable regression analysis, anemia at admission was a significant risk factor for discharge to a nursing home and readmission < 90 days, but not for mortality. Indication for ABT, age and ASA classification were independent risk factors for mortality at all moments, only the mortality rate for the 3-12 month interval was not influenced by ABT. An indication for an ABT was the largest negative contributor to a longer LOS (OR 2.26, 95% CI 1.73-2.94) and the second largest for delirium (OR 1.67, 95% CI 1.28-2.20). Conclusions: This study has demonstrated that anemia at admission and postoperative anemia needing an ABT (PANT) were independent risk factors for worse outcome in hip fracture patients. In multivariable regression analysis, anemia as such had no effect on mortality, due to a rescue effect of PANT. In-hospital, 3- and 12-month mortality was negatively affected by PANT, with the main effect in the first 3 months postoperatively

    Polyethylene thickness is a risk factor for wear necessitating insert exchange

    Get PDF
    PURPOSE: The aim of this observational study was to investigate the optimal minimal polyethylene (PE) thickness in total knee arthroplasty (TKA) and identify other risk factors associated with revision of the insert due to wear. METHODS: A total of 84 TKA were followed for 11-16 years. All patients received the same prosthesis design (Interax; Howmedica/ Stryker) with halfbearings: separate PE-inserts medially and laterally. Statistical analysis comprised Cox-regression to correct for confounding. RESULTS: Eight knees (9.5%) had been revised due to thinning inserts and an additional patient is scheduled for revision. PE thickness, diagnosis, BMI and weight are risk factors for insert exchange. For each millimetre decrease in PE thickness, the risk of insert exchange increases 3.0 times, which remains after correction for age, gender, weight, diagnosis and femoral-tibial angle. Insert exchange was 4.73 times more likely in OA-patients compared to RA-patients. For every unit increase in BMI and weight the risk for insert exchange increases 1.40 times and 1.14 times, respectively. CONCLUSIONS: In conclusion we therefore advise against the use of thin PE inserts in modular TKA and recommend PE inserts with a minimal 8-mm thickness.Optimising joint reconstruction management in arthritis and bone tumour patient
    • …
    corecore