Design and Tests of the Silicon Sensors for the ZEUS Micro Vertex Detector
To fully exploit the HERA-II upgrade,the ZEUS experiment has installed a
Micro Vertex Detector (MVD) using n-type, single-sided, silicon micro-strip
sensors with capacitive charge division. The sensors have a readout pitch of
120 micrometers, with five intermediate strips (20 micrometer strip pitch). The
designs of the silicon sensors and of the test structures used to verify the
technological parameters, are presented. Results on the electrical measurements
are discussed. A total of 1123 sensors with three different geometries have
been produced by Hamamatsu Photonics K.K. Irradiation tests with reactor
neutrons and Co-60 photons have been performed for a small sample of sensors.
The results on neutron irradiation (with a fluence of 1 x 10^{13} 1 MeV
equivalent neutrons / cm^2) are well described by empirical formulae for bulk
damage. The Co-60 photons (with doses up to 2.9 kGy) show the presence of
generation currents in the SiO_2-Si interface, a large shift of the flatband
voltage and a decrease of the hole mobility.Comment: 33 pages, 25 figures, 3 tables, accepted for publication in NIM
Deeltjesfysica: onvoorstelbare waarnemingen?
In een 27 km lange tunnel onder de grond in de buurt van Genève (de deeltjesversneller Large Hadron Collider (LHC) van het Europese onderzoeksinstituut CERN) wordt na een jarenlange voorbereiding de laatste hand gelegd aan een deeltjesversneller. De versneller is gemaakt om protonen met elkaar in botsing te brengen. De protonen krijgen een ongeëvenaarde snelheid en op deze manier zullen de botsingen inzicht verschaffen in het diepst van de materie. Structuur der materie op een afstandschaal van 0.000000000000000001 meter ofwel een attometer. Onvoorstelbaar klein
Beam Test of Silicon Strip Sensors for the ZEUS Micro Vertex Detector
For the HERA upgrade, the ZEUS experiment has designed and installed a high
precision Micro Vertex Detector (MVD) using single sided micro-strip sensors
with capacitive charge division. The sensors have a readout pitch of 120
microns, with five intermediate strips (20 micron strip pitch). An extensive
test program has been carried out at the DESY-II testbeam facility. In this
paper we describe the setup developed to test the ZEUS MVD sensors and the
results obtained on both irradiated and non-irradiated single sided micro-strip
detectors with rectangular and trapezoidal geometries. The performances of the
sensors coupled to the readout electronics (HELIX chip, version 2.2) have been
studied in detail, achieving a good description by a Monte Carlo simulation.
Measurements of the position resolution as a function of the angle of incidence
are presented, focusing in particular on the comparison between standard and
newly developed reconstruction algorithms.Comment: 41 pages, 21 figures, 2 tables, accepted for publication in NIM
3+1 dimensional Yang-Mills theory as a local theory of evolution of metrics on 3 manifolds
An explicit canonical transformation is constructed to relate the physical
subspace of Yang-Mills theory to the phase space of the ADM variables of
general relativity. This maps 3+1 dimensional Yang-Mills theory to local
evolution of metrics on 3 manifolds.Comment: 7 pages, revte
- …