879 research outputs found
New ring shear deformation apparatus for three-dimensional multiphase experiments: First results
Multiphase deformation, where a solid and fluid phase deform simultaneously, play a crucial role in a variety of geological hazards, such as landslides, glacial slip, and the transition from earthquakes to slow slip. In all these examples a continuous, viscous or fluid-like phase is mixed with a granular or brittle phase where both phases deform simultaneously when stressed. Understanding the interaction between the phases and how they will impact deformation dynamics is essential to improve hazard assessments for a wide variety of geo-hazards. Here, we present the design and first experimental results from a ring shear deformation apparatus capable of deforming multiple phases simultaneously. The experimental design allows for three dimensional observations during deformation in addition to unlimited shear strain, controllable normal force, and a variety of boundary conditions. To impose shear deformation, either the experimental chamber or lid rotate around its central axis while the other remains stationary. Normal and pulling force data are collected with force gauges located on the lid of the apparatus and between the pulling motor and the experimental chamber. Experimental materials are chosen to match the light refraction index of the experimental chamber, such that 3D observations can be made throughout the experiment with the help of a laser light sheet. We present experimental results where we deform hydropolymer orbs and cubes (brittle phase) and Carbopol® hydropolymer gel (fluid phase). Preliminary results show variability in force measurements and deformation styles between solid and fluid end member experiments. The ratio of solids to fluids and their relative competencies in multiphase experiments control deformation dynamics, which range from stick-slip to creep. The presented experimental strategy has the potential to shed light on multi-phase processes associated with multiple geo-hazards.</p
Initial experience and outcome of a new hemodialysis access device for catheter-dependent patients
ObjectiveThe effects of a new long-term subcutaneous vascular access device were studied in access-challenged patients who were poor candidates for fistulas or grafts due to venous obstruction. Bacteremia rates, patency, and function of the Hemodialysis Reliable Outflow (HeRO) Vascular Access Device (Hemosphere Inc, Minneapolis, Minn) were evaluated.MethodsThe HeRO device consists of a 6-mm expanded polytetrafluoroethylene graft attached to a 5-mm nitinol-reinforced silicone outflow component designed to bypass venous stenoses and enter the internal jugular vein directly, providing continuous arterial blood flow into the right atrium. The HeRO device was studied in a multicenter clinical trial to test the hypothesis that access-challenged patients would experience a statistically significant reduction in bacteremia rates compared with a tunneled dialysis catheter (TDC) literature control of 2.3/1000 days. HeRO-related bacteremia rates, adequacy of dialysis, patency, and adverse events were analyzed.ResultsThe HeRO device was implanted in 36 access-challenged patients who were followed for a mean 8.6 months (9931 HeRO days). The HeRO-related bacteremia rate was 0.70/1000 days. All HeRO-related bacteremias occurred during the bridging period when a TDC was still implanted before HeRO graft incorporation. HeRO adequacy of dialysis (mean Kt/V) was 1.7. HeRO primary patency was 38.9%, and secondary patency was 72.2%.ConclusionsIn access-challenged patients, a statistically significant reduction in HeRO-related bacteremia was noted compared with TDC literature. The device had similar function and patency compared with conventional arteriovenous graft literature
Liquid Chromatography Electron Capture Dissociation Tandem Mass Spectrometry (LC-ECD-MS/MS) versus Liquid Chromatography Collision-induced Dissociation Tandem Mass Spectrometry (LC-CID-MS/MS) for the Identification of Proteins
Electron capture dissociation (ECD) offers many advantages over the more traditional fragmentation techniques for the analysis of peptides and proteins, although the question remains: How suitable is ECD for incorporation within proteomic strategies for the identification of proteins? Here, we compare LC-ECD-MS/MS and LC-CID-MS/MS as techniques for the identification of proteins.Experiments were performed on a hybrid linear ion trapâFourier transform ion cyclotron resonance mass spectrometer. Replicate analyses of a six-protein (bovine serum albumin, apo-transferrin,lysozyme, cytochrome c, alcohol dehydrogenase, and β-galactosidase) tryptic digest were performed and the results analyzed on the basis of overall protein sequence coverage and sequence tag lengths within individual peptides. The results show that although protein coverage was lower for LC-ECDMS/MS than for LC-CID-MS/MS, LC-ECD-MS/MS resulted in longer peptide sequence tags,providing greater confidence in protein assignment
Foot health education for people with rheumatoid arthritis : the practitioner's perspective
Background: Patient education is considered to be a key role for podiatrists in the management of patients with rheumatoid arthritis (RA). Patient education has undoubtedly led to improved clinical outcomes, however no attempts have been made to optimise its content or delivery to maximise benefits within the context of the foot affected by rheumatoid arthritis. The aim of this study was to identify the nature and content of podiatrists' foot health education for people with RA. Any potential barriers to its provision were also explored.
Methods: A focus group was conducted. The audio dialogue was recorded digitally, transcribed verbatim and analysed using a structured, thematic approach. The full transcription was verified by the focus group as an accurate account of what was said. The thematic analysis framework was verified by members of the research team to ensure validity of the data.
Results: Twelve members (all female) of the north west Podiatry Clinical Effectiveness Group for Rheumatology participated. Six overarching themes emerged: (i) the essence of patient education; (ii) the content; (iii) patient-centred approach to content and timing; (iv) barriers to provision; (v) the therapeutic relationship; and (vi) tools of the trade.
Conclusion: The study identified aspects of patient education that this group of podiatrists consider most important in relation to its: content, timing, delivery and barriers to its provision. General disease and foot health information in relation to RA together with a potential prognosis for foot health, the role of the podiatrist in management of foot health, and appropriate self-management strategies were considered to be key aspects of content, delivered according to the needs of the individual. Barriers to foot health education provision, including financial constraints and difficulties in establishing effective therapeutic relationships, were viewed as factors that strongly influenced foot health education provision. These data will contribute to the development of a patient-centred, negotiated approach to the provision of foot health education for people with RA
Improvements in Modeling 90 degree Bleed Holes for Supersonic Inlets
The modeling of porous bleed regions as boundary conditions in computational fluid dynamics (CFD) simulations of supersonic inlet flows has been improved through a scaling of sonic flow coefficient data for 90deg bleed holes. The scaling removed the Mach number as a factor in computing the sonic flow coefficient and allowed the data to be fitted with a quadratic equation, with the only factor being the ratio of the plenum static pressure to the surface static pressure. The implementation of the bleed model into the Wind-US CFD flow solver was simplified by no longer requiring the evaluation of the flow properties at the boundary-layer edge. The quadratic equation can be extrapolated to allow the modeling of small amounts of blowing, which can exist when recirculation of the bleed flow occurs within the bleed region. The improved accuracy of the bleed model was demonstrated through CFD simulations of bleed regions on a flat plate in supersonic flow with and without an impinging oblique shock. The bleed model demonstrated good agreement with experimental data and three-dimensional CFD simulations of bleed holes
Efficiency of Collisionally-activated dissociation and 193-nm photodissociation of peptide ions in fourier transform mass spectrometry
AbstractFor tandem mass spectrometry, the Fourier transform instrument exhibits advantages for the use of collisionally-activated dissociation (CAD). The CAD energy deposited in larger ions can be greatly increased by extending the collision time to as much as 120 s, and the efficiency of trapping and measuring CAD product ions in many times greater than the found for triple-quadrupole or magnetic sector instruments, although the increased pressure from the collision gas is an offsetting disadvantage. A novel system that uses the same laser for photodesorption of ions and their subsequent photodissociation can produce complete dissociation of larger oligopeptide ions and unusually abundant fragment ions. In comparison to CAD, much more internal energy can be deposited in the primary ions using 193-nm photons, sufficient to dissociate peptide ions of m/z > 2000. Mass spectra closely resembling ion photodissociation spectra can also be obtained by neutral photodissociation (193-nm laser irradiation of the sample) followed by ion photodesorption
- âŚ