1,462 research outputs found

    Observation of coupled-cavity structures in metamaterials

    Get PDF
    Cataloged from PDF version of article.In this letter, we investigated the transmission properties of metamaterial based coupled-cavity structures. We first calculated the effective parameters of a split-ring resonator (SRR) and composite metamaterial (CMM) structures. Subsequently, we introduced coupled-cavity structures and presented the transmission spectrum of SRR and CMM based coupled-cavity structures. The splitting of eigenmodes was observed due to the interaction between the localized electromagnetic cavity modes. Finally, the dispersion relation and normalized group velocity of the coupled-cavity structures were calculated. The maximum group velocity was found to be 100 times smaller than the speed of light in vacuum. (C) 2008 American Institute of Physics

    Experimental observation of subwavelength localization using metamaterial-based cavities

    Get PDF
    Cataloged from PDF version of article.We report subwavelength localization of electromagnetic fields within cavities based on metamaterials. Cavity resonances are observed in the transmission spectrum of a split-ring resonator and composite metamaterials cavity structures. These cavity resonances are shown to exhibit high-quality factors. Since the unit cells of metamaterials are much smaller than the operation wavelength, subwavelength localization is possible within these metamaterial cavity structures. In the present Letter, we show that the electromagnetic field is localized into a region of λ/8, where λ is the cavity resonance wavelength. © 2008 Optical Society of America

    Experimental observation of cavity formation in composite metamaterials

    Get PDF
    Cataloged from PDF version of article.In this paper, we investigated one of the promising applications of left-handed metamaterials: composite metamaterial based cavities. Four different cavity structures operating in the microwave regime were constructed, and we observed cavity modes on the transmission spectrum with different quality factors. The effective permittivity and permeability of the CMM structure and cavity structure were calculated by use of a retrieval procedure. Subsequently, in taking full advantage of the effective medium theory, we modeled CMM based cavities as one dimensional Fabry-Perot resonators with a subwavelength cavity at the center. We calculated the transmission from the Fabry-Perot resonator model using the one-dimensional transfer matrix method, which is in good agreement with the measured result. Finally, we investigated the Fabry-Perot resonance phase condition for a CMM based cavity, in which the condition was satisfied at the cavity frequency. Therefore, our results show that it is possible to treat metamaterial based cavities as one-dimensional Fabry-Perot resonators with a subwavelength cavity. ©2008 Optical Society of America

    Antithrombin significantly influences platelet adhesion onto immobilized fibrinogen in an in-vitro system simulating low flow

    Get PDF
    BACKGROUND: Adhesion of platelets onto immobilized fibrinogen is of importance in initiation and development of thrombosis. According to a recent increase in evidence of a multiple biological property of antithrombin, we evaluated the influence of antithrombin on platelet adhesion onto immobilized fibrinogen using an in-vitro flow system. METHODS: Platelets in anticoagulated whole blood (29 healthy blood donors) were labelled with fluorescence dye and perfused through a rectangular flow chamber (shear rates of 13 s(-1 )to 1500 s(-1)). Platelet adhesion onto fibrinogen-coated slips was assessed using a fluorescence laser-scan microscope and compared to the plasma antithrombin activity. Additionally the effect of supraphysiological AT supplementation on platelets adhesion rate was evaluated. RESULTS: Within a first minute of perfusion, an inverse correlation between platelet adhesion and plasma antithrombin were observed at 13 s(-1 )and 50 s(-1 )(r = -0.48 and r = -0.7, p < 0.05, respectively). Significant differences in platelet adhesion related to low (92 ± 3.3%) and high (117 ± 4.1%) antithrombin activity (1786 ± 516 U vs. 823 ± 331 U, p < 0.05) at low flow rate (13 s(-1), within first minute) have been found. An in-vitro supplementation of whole blood with antithrombin increased the antithrombin activity up to 280% and platelet adhesion rate reached about 65% related to the adhesion rate in a non-supplemented blood (1.25 ± 0.17 vs. 1.95 ± 0.4 p = 0.008, respectively). CONCLUSION: It appears that antithrombin in a low flow system suppresses platelet adhesion onto immobilized fibrinogen independently from its antithrombin activity. A supraphysiological substitution of blood with antithrombin significantly reduces platelet adhesion rate. This inhibitory effect might be of clinical relevance

    Platelet adhesion onto immobilized fibrinogen under arterial and venous in-vitro flow conditions does not significantly differ between men and women

    Get PDF
    BACKGROUND: Gender-related differences in incidence of arterial thrombosis have been a focus of interest for years. The platelet integrin αIIbβ3 is primarily responsible for the interaction between platelets and fibrinogen and consecutive thrombus growth. In this study, we evaluated platelet adhesion onto immobilized fibrinogen under venous and arterial flow conditions in men and women. METHODS: Platelets in whole anticoagulated blood were labelled with the fluorescence dye Mepacrine and perfused through the rectangular flow chamber over glass cover slips coated with fibrinogen (shear rates of 50 s(-1), 500 s(-1 )and 1500 s(-1)). A fluorescence laser-scan microscope was used for visualisation and quantification of platelet adhesion at 15 seconds, 1 and 5 minutes after the start of perfusion. RESULTS: During perfusion, the platelet adhesion linearly increased in regard to exposition time and shear rate. After five minutes of perfusion the platelet adhesion onto immobilized fibrinogen showed no significant gender related difference, neither at 50 s(-1 )nor at 500 s(-1 )and 1500 s(-1 )(p > 0.05), respectively. No significant difference in platelet adhesion onto immobilized fibrinogen, in regard to the menopausal status, was either observed (p > 0.05). CONCLUSION: In our in vitro experimental system, hormonal differences between men and women did not influence platelet adhesion onto immobilized fibrinogen, neither under venous nor under arterial rheological conditions

    The screening power of methylenetetrahydrofolate reductase C677T polymorphism versus plasma homocysteine concentration in patients with stenosis of the internal carotid artery

    Get PDF
    BACKGROUND: Hyperhomocysteinemia is an important and independent risk factor for vascular disease. About 35% of patients with stroke and 47% of patients with peripheral arterial disease have elevated plasma homocysteine (HCY) concentrations. The relationship between plasma HCY and the methylentetrahydrofolate reductase (MTHFR) C677T polymorphism is still unclear, especially in regard to screening/diagnostic power. METHODS: This case-control study was performed on 96 patients, who underwent surgery due to asymptomatic or symptomatic high grade stenosis of the internal carotid artery (ICA), and 96 healthy age and sex-matched, controls. Plasma HCY concentration was determined using a commercial kit for fully automated analysis (AxSYM, Abbott). The C677T polymorphism of the MTHFR-gene was assessed by PCR. RESULTS: The mean plasma HCY concentration was significantly higher in the group with stenosis of ICA compared to the controls, 12.43 ± 6.96 μM and 10.16 ± 3.16 μM, respectively, (p < 0.05). An HCY plasma concentration of 1.5 SD above the mean value of the control group, was defined as cut-off for a pathological versus physiological plasma concentration. The sensitivity and specificity of HCY was 0.27 and 0.94, respectively. The positive predictive value was 0.82. There was no significant difference in the frequency of the MTHFR 677 CT and TT genotype between patients and controls (47% vs. 47% and 8.3% vs. 11.4%, respectively). Carriers of the T-allele (CT and TT genotypes) have significantly higher plasma HCY concentrations than CC patients, 14.1 ± 7.6 μM and 10.29 ± 5.2 μM, respectively, p < 0.05. Sensitivity and specificity of the MTHFR C677T polymorphism (T-allele) were 0.56 and 0.40, respectively. The positive predictive value was 0.48. There was no significant difference in plasma HCY or genotype frequency of the MTHFR C677T polymorphism between asymptomatic and symptomatic patients. CONCLUSION: Our study shows that in a population with a given pretest disease probability of 50%, the determination of plasma HCY concentration, with a positive predictive value of 0.82, is more suitable for screening of patients at risk than analysis of the MTHFR C677T polymorphism
    corecore