4,383 research outputs found

    On the localization properties of an RPWELL gas-avalanche detector

    Full text link
    A study of the localization properties of a single-element Resistive Plate WELL (RPWELL) detector is presented. The detector comprises of a single-sided THick Gaseous Electron Multiplier (THGEM) coupled to a segmented readout anode through a doped silicate-glass plate of 1010^{10} Ω⋅\Omega\cdotcm bulk resistivity. Operated in ambient Ne/(5%\%CH4_4) gas, the detector has been investigated with 150 GeV muons at CERN-SPS. Signals induced through the resistive plate on anode readout strips were recorded with APV25/SRS electronics. The experimental results are compared with that of Monte Carlo simulations. The effects of various physics phenomena on the position resolution are discussed. The measured position resolution in the present configuration is 0.28 mm RMS - compatible with the holes-pattern of the multiplier. Possible ways for improving the detector position resolution are suggested

    The Thin Gap Chambers database experience in test beam and preparations for ATLAS

    Full text link
    Thin gap chambers (TGCs) are used for the muon trigger system in the forward region of the LHC experiment ATLAS. The TGCs are expected to provide a trigger signal within 25 ns of the bunch spacing. An extensive system test of the ATLAS muon spectrometer has been performed in the H8 beam line at the CERN SPS during the last few years. A relational database was used for storing the conditions of the tests as well as the configuration of the system. This database has provided the detector control system with the information needed for configuration of the front end electronics. The database is used to assist the online operation and maintenance. The same database is used to store the non event condition and configuration parameters needed later for the offline reconstruction software. A larger scale of the database has been produced to support the whole TGC system. It integrates all the production, QA tests and assembly information. A 1/12th model of the whole TGC system is currently in use for testing the performance of this database in configuring and tracking the condition of the system. A prototype of the database was first implemented during the H8 test beams. This paper describes the database structure, its interface to other systems and its operational performance.Comment: Proceedings IEEE, Nuclear Science Symposium 2005, Stockholm, Sweeden, May 200

    A variant of the Mukai pairing via deformation quantization

    Full text link
    We give a new method to prove a formula computing a variant of Caldararu's Mukai pairing \cite{Cal1}. Our method is based on some important results in the area of deformation quantization. In particular, part of the work of Kashiwara and Schapira in \cite{KS} as well as an algebraic index theorem of Bressler, Nest and Tsygan in \cite{BNT},\cite{BNT1} and \cite{BNT2} are used. It is hoped that our method is useful for generalization to settings involving certain singular varieties.Comment: 8 pages. Comments and suggestions welcom

    Convex Polytopes and Quasilattices from the Symplectic Viewpoint

    Get PDF
    We construct, for each convex polytope, possibly nonrational and nonsimple, a family of compact spaces that are stratified by quasifolds, i.e. each of these spaces is a collection of quasifolds glued together in an suitable way. A quasifold is a space locally modelled on Rk\R^k modulo the action of a discrete, possibly infinite, group. The way strata are glued to each other also involves the action of an (infinite) discrete group. Each stratified space is endowed with a symplectic structure and a moment mapping having the property that its image gives the original polytope back. These spaces may be viewed as a natural generalization of symplectic toric varieties to the nonrational setting.Comment: LaTeX, 29 pages. Revised version: TITLE changed, reorganization of notations and exposition, added remarks and reference

    A Method of Drusen Measurement Based on the Geometry of Fundus Reflectance

    Get PDF
    BACKGROUND: The hallmarks of age-related macular degeneration, the leading cause of blindness in the developed world, are the subretinal deposits known as drusen. Drusen identification and measurement play a key role in clinical studies of this disease. Current manual methods of drusen measurement are laborious and subjective. Our purpose was to expedite clinical research with an accurate, reliable digital method. METHODS: An interactive semi-automated procedure was developed to level the macular background reflectance for the purpose of morphometric analysis of drusen. 12 color fundus photographs of patients with age-related macular degeneration and drusen were analyzed. After digitizing the photographs, the underlying background pattern in the green channel was leveled by an algorithm based on the elliptically concentric geometry of the reflectance in the normal macula: the gray scale values of all structures within defined elliptical boundaries were raised sequentially until a uniform background was obtained. Segmentation of drusen and area measurements in the central and middle subfields (1000 μm and 3000 μm diameters) were performed by uniform thresholds. Two observers using this interactive semi-automated software measured each image digitally. The mean digital measurements were compared to independent stereo fundus gradings by two expert graders (stereo Grader 1 estimated the drusen percentage in each of the 24 regions as falling into one of four standard broad ranges; stereo Grader 2 estimated drusen percentages in 1% to 5% intervals). RESULTS: The mean digital area measurements had a median standard deviation of 1.9%. The mean digital area measurements agreed with stereo Grader 1 in 22/24 cases. The 95% limits of agreement between the mean digital area measurements and the more precise stereo gradings of Grader 2 were -6.4 % to +6.8 % in the central subfield and -6.0 % to +4.5 % in the middle subfield. The mean absolute differences between the digital and stereo gradings 2 were 2.8 +/- 3.4% in the central subfield and 2.2 +/- 2.7% in the middle subfield. CONCLUSIONS: Semi-automated, supervised drusen measurements may be done reproducibly and accurately with adaptations of commercial software. This technique for macular image analysis has potential for use in clinical research

    The Resistive-Plate WELL with Argon mixtures - a robust gaseous radiation detector

    Full text link
    A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was operated with 150 GeV/c muon and pion beams in Ne/(5%CH4_4), Ar/(5%CH4_4) and Ar/(7%CO2_2); signals were recorded with 1 cm2^2 square pads and SRS/APV25 electronics. Detection efficiency values greater than 98% were reached in all the gas mixtures, at average pad multiplicity of 1.2. The use of the 109^9{\Omega}cm resistive plate resulted in a completely discharge-free operation also in intense pion beams. The efficiency remained essentially constant at 98-99% up to fluxes of ∼\sim104^4Hz/cm2^2, dropping by a few % when approaching 105^5 Hz/cm2^2. These results pave the way towards cost-effective, robust, efficient, large-scale detectors for a variety of applications in future particle, astro-particle and applied fields. A potential target application is digital hadron calorimetry.Comment: presented at the 2016 VIenna Conf. On instrumentation. Submitted to the Conference proceeding
    • …