2 research outputs found

    Predicting Factors Associated with Hypoglycemia Reduction with Automated Predictive Insulin Suspension in Patients at High Risk of Severe Hypoglycemia: An Analysis from the SMILE Randomized Trial

    No full text
    Background: This analysis from the SMILE randomized study was performed to identify predictive factors associated with the greatest reductions in hypoglycemia with the Medtronic MiniMed™ 640G Suspend before low feature in adults with type 1 diabetes at high risk of severe hypoglycemia. Methods: Clinical and treatment-related factors associated with decreased sensor hypoglycemia (SH) were identified in participants from the intervention arm by univariate and multivariate analyses. Results: The reduction in SH events <54 mg/dL (<3.0 mmol/L) in the intervention group was significantly (P < 0.0001) associated with the baseline mean number of sensor hypoglycemic events (MNSHE) <54 mg/dL. When excluding continuous glucose monitoring (CGM) factors not readily available (MNSHE, duration of SH events, area under the curve, mean amplitude of glycemic excursions), only the baseline mean time spent <54 mg/dL was found to be a significant independent predictor factor (P < 0.0001). Baseline HbA1c, mean self-monitoring of blood glucose (SMBG), and coefficient of variation of SMBG were significant, although weak, predictors in the absence of any CGM data. Conclusions: The greatest reductions in SH events achieved with the MiniMed 640G system with the Suspend before low feature were seen in participants with higher baseline MNSHE. Measuring these (usually uncollected) events can be a useful tool to predict hypoglycemia reduction. ClinicalTrials.gov Registration Identifier NCT02733991

    Consensus Recommendations for the Use of Automated Insulin Delivery Technologies in Clinical Practice

    No full text
    The significant and growing global prevalence of diabetes continues to challenge people with diabetes (PwD), healthcare providers, and payers. While maintaining near-normal glucose levels has been shown to prevent or delay the progression of the long-term complications of diabetes, a significant proportion of PwD are not attaining their glycemic goals. During the past 6 years, we have seen tremendous advances in automated insulin delivery (AID) technologies. Numerous randomized controlled trials and real-world studies have shown that the use of AID systems is safe and effective in helping PwD achieve their long-term glycemic goals while reducing hypoglycemia risk. Thus, AID systems have recently become an integral part of diabetes management. However, recommendations for using AID systems in clinical settings have been lacking. Such guided recommendations are critical for AID success and acceptance. All clinicians working with PwD need to become familiar with the available systems in order to eliminate disparities in diabetes quality of care. This report provides much-needed guidance for clinicians who are interested in utilizing AIDs and presents a comprehensive listing of the evidence payers should consider when determining eligibility criteria for AID insurance coverage
    corecore