24 research outputs found

    IMRT for image-guided single vocal cord irradiation

    Get PDF
    Purpose: We have been developing an image-guided single vocal cord irradiation technique to treat patients with stage T1a glottic carcinoma. In the present study, we compared the dose coverage to the affected vocal cord and the dose delivered to the organs at risk using conventional, intensity-modulated radiotherapy (IMRT) coplanar, and IMRT non-coplanar techniques. Methods and Materials: For 10 patients, conventional treatment plans using two laterally opposed wedged 6-MV photon beams were calculated in XiO (Elekta-CMS treatment planning system). An in-house IMRT/beam angle optimization algorithm was used to obtain the coplanar and non-coplanar optimized beam angles. Using these angles, the IMRT plans were generated in Monaco (IMRT treatment planning system, Elekta-CMS) with the implemented Monte Carlo dose calculation algorithm. The organs at risk included the contralateral vocal cord, arytenoids, swallowing muscles, carotid arteries, and spinal cord. The prescription dose was 66 Gy in 33 fractions. Results: For the conventional plans and coplanar and non-coplanar IMRT plans, the population-averaged mean dose ± standard deviation to the planning target volume was 67 ± 1 Gy. The contralateral vocal cord dose was reduced from 66 ± 1 Gy in the conventional plans to 39 ± 8 Gy and 36 ± 6 Gy in the coplanar and non-coplanar IMRT plans, respectively. IMRT consistently reduced the doses to the other organs at risk. Conclusions: Single vocal cord irradiation with IMRT resulted in good target coverage and provided significant sparing of the critical structures. This has the potential to improve the quality-of-life outcomes after RT and maintain the same local control rates

    Plan-library supported automated replanning for online-adaptive intensity-modulated proton therapy of cervical cancer

    Get PDF
    Background: Intensity-modulated proton therapy is sensitive to inter-fraction variations, including density changes along the pencil-beam paths and variations in organ-shape and location. Large dayto-day variations are seen for cervical cancer patients. The purpose of this study was to develop and evaluate a novel method for online selection of a plan from a patient-specific library of prior plans for different anatomies, and adapt it for the daily anatomy. Material and methods: The patient-specific library of prior plans accounting for altered target geometries was generated using a pretreatment established target motion model. Each fraction, the best fitting prior plan was selected. This prior plan was adapted using (1) a restoration of spot-positions (Bragg peaks) by adapting the energies to the new water equivalent path lengths; and (2) a spot addition to fully cover the target of the day, followed by a fast optimization of the spot-weights with the reference point method (RPM) to obtain a Pareto-optimal plan for the daily anatomy. Spot addition and spot-weight optimization could be repeated iteratively. The patient cohort consisted of six patients with in total 23 repeat-CT scans, with a prescribed dose of 45 Gy(RBE) to the primary tumor and the nodal CTV. Using a 1-plan-library (one prior plan based on all motion in the motion model) was compared to choosing from a 2-plan-library (two prior plans based on part of the motion). Results: Applying the prior-plan adaptation method with one iteration of adding spots resulted in clinically acceptable target coverage (V95% 95% and V107% 2%) for 37/46 plans using the 1-planlibrary and 41/46 plans for the 2-plan-library. When adding spots twice, the 2-plan-library approach could obtain acceptable coverage for all scans, while the 1-plan-library approach showed V107% > 2% for 3/46 plans. Similar OAR results were obtained. Conclusion: The automated prior-plan adaptation method can successfully adapt for the large day-today variations observed in cervical cancer patients

    Radiation Therapy Techniques and Treatment-Related Toxicity in the PORTEC-3 Trial:Comparison of 3-Dimensional Conformal Radiation Therapy Versus Intensity-Modulated Radiation Therapy

    Get PDF
    Purpose Radiation therapy techniques have developed from 3-dimensional conformal radiation therapy (3DCRT) to intensity modulated radiation therapy (IMRT), with better sparing of the surrounding normal tissues. The current analysis aimed to investigate whether IMRT, compared to 3DCRT, resulted in fewer adverse events (AEs) and patient-reported symptoms in the randomized PORTEC-3 trial for high-risk endometrial cancer. Methods and Materials Data on AEs and patient-reported quality of life (QoL) of the PORTEC-3 trial were available for analysis. Physician-reported AEs were graded using Common Terminology Criteria for Adverse Events v3.0. QoL was assessed by the European Organisation for Research and Treatment of Cancer QLQC30, CX24, and OV28 questionnaires. Data were compared between 3DCRT and IMRT. A P value of ≤ .01 was considered statistically significant due to the risk of multiple testing. For QoL, combined scores 1 to 2 (“not at all” and “a little”) versus 3 to 4 (“quite a bit” and “very much”) were compared between the techniques. Results Of 658 evaluable patients, 559 received 3DCRT and 99 IMRT. Median follow-up was 74.6 months. During treatment no significant differences were observed, with a trend for more grade ≥3 AEs, mostly hematologic and gastrointestinal, after 3DCRT (37.7% vs 26.3%, P = .03). During follow-up, 15.4% (vs 4%) had grade ≥2 diarrhea, and 26.1% (vs 13.1%) had grade ≥2 hematologic AEs after 3DCRT (vs IMRT) (both P < .01). Among 574 (87%) patients evaluable for QoL, 494 received 3DCRT and 80 IMRT. During treatment, 37.5% (vs 28.6%) reported diarrhea after 3DCRT (vs IMRT) (P = .125); 22.1% (versus 10.0%) bowel urgency (P = 0039), and 18.2% and 8.6% abdominal cramps (P = .058). Other QoL scores showed no differences. Conclusions IMRT resulted in fewer grade ≥3 AEs during treatment and significantly lower rates of grade ≥2 diarrhea and hematologic AEs during follow-up. Trends toward fewer patient-reported bowel urgency and abdominal cramps were observed after IMRT compared to 3DCRT

    Intensity-modulated radiation therapy: emerging cancer treatment technology

    Get PDF
    The use of intensity-modulated radiation therapy (IMRT) is rapidly advancing in the field of radiation oncology. Intensity-modulated radiation therapy allows for improved dose conformality, thereby affording the potential to decrease the spectrum of normal tissue toxicities associated with IMRT. Preliminary results with IMRT are quite promising; however, the clinical data is relatively immature and overall patient numbers remain small. High-quality IMRT requires intensive physics support and detailed knowledge of three-dimensional anatomy and patterns of tumour spread. This review focuses on basic principles, and highlights the clinical implementation of IMRT in head and neck and prostate cancer

    Radiation therapy techniques and treatment-related toxicity in the PORTEC-3 trial: comparison of 3-dimensional conformal radiation therapy versus intensity-modulated radiation therapy

    Get PDF
    Purpose: Radiation therapy techniques have developed from 3-dimensional conformal radiation therapy (3DCRT) to intensity modulated radiation therapy (IMRT), with better sparing of the surrounding normal tissues. The current analysis aimed to investigate whether IMRT, compared to 3DCRT, resulted in fewer adverse events (AEs) and patient-reported symptoms in the randomized PORTEC-3 trial for high-risk endometrial cancer.Methods and materials: Data on AEs and patient-reported quality of life (QoL) of the PORTEC-3 trial were available for analysis. Physician-reported AEs were graded using Common Terminology Criteria for Adverse Events v3.0. QoL was assessed by the European Organisation for Research and Treatment of Cancer QLQC30, CX24, and OV28 questionnaires. Data were compared between 3DCRT and IMRT. A P value of = .01 was considered statistically significant due to the risk of multiple testing. For QoL, combined scores 1 to 2 ("not at all" and "a little") versus 3 to 4 ("quite a bit" and "very much") were compared between the techniques.Results: Of 658 evaluable patients, 559 received 3DCRT and 99 IMRT. Median follow-up was 74.6 months. During treatment no significant differences were observed, with a trend for more grade =3 AEs, mostly hematologic and gastrointestinal, after 3DCRT (37.7% vs 26.3%, P = .03). During follow-up, 15.4% (vs 4%) had grade >= 2 diarrhea, and 26.1% (vs 13.1%) had grade >= 2 hematologic AEs after 3DCRT (vs IMRT) (both P = 3 AEs during treatment and significantly lower rates of grade >= 2 diarrhea and hematologic AEs during follow-up. Trends toward fewer patient-reported bowel urgency and abdominal cramps were observed after IMRT compared to 3DCRT. (C) 2021 The Authors. Published by Elsevier Inc.Biological, physical and clinical aspects of cancer treatment with ionising radiatio

    Cone-Beam Computed Tomography-Guided Positioning of Laryngeal Cancer Patients with Large Interfraction Time Trends in Setup and Nonrigid Anatomy Variations

    No full text
    Purpose: To investigate interfraction setup variations of the primary tumor, elective nodes, and vertebrae in laryngeal cancer patients and to validate protocols for cone beam computed tomography (CBCT)-guided correction.Methods and Materials: For 30 patients, CBCT-measured displacements in fractionated treatments were used to investigate population setup errors and to simulate residual setup errors for the no action level (NAL) offline protocol, the extended NAL (eNAL) protocol, and daily CBCT acquisition with online analysis and repositioning.Results: Without corrections, 12 of 26 patients treated with radical radiation therapy would have experienced a gradual change (time trend) in primary tumor setup >= 4 mm in the cranio-caudal (CC) direction during the fractionated treatment (11/12 in caudal direction, maximum 11 mm). Due to these trends, correction of primary tumor displacements with NAL resulted in large residual CC errors (required margin 6.7 mm). With the weekly correction vector adjustments in eNAL, the trends could be largely compensated (CC margin 3.5 mm). Correlation between movements of the primary and nodal clinical target volumes (CTVs) in the CC direction was poor (r(2) = 0.15). Therefore, even with online setup corrections of the primary CTV, the required CC margin for the nodal CTV was as large as 6.8 mm. Also for the vertebrae, large time trends were observed for some patients. Because of poor CC correlation (r(2) = 0.19) between displacements of the primary CTV and the vertebrae, even with daily online repositioning of the vertebrae, the required CC margin around the primary CTV was 6.9 mm.Conclusions: Laryngeal cancer patients showed substantial interfraction setup variations, including large time trends, and poor CC correlation between primary tumor displacements and motion of the nodes and vertebrae (internal tumor motion). These trends and nonrigid anatomy variations have to be considered in the choice of setup verification protocol and planning target volume margins. eNAL could largely compensate time trends with minor prolongation of fraction time. (c) 2013 Elsevier Inc.Biological, physical and clinical aspects of cancer treatment with ionising radiatio
    corecore