1,176 research outputs found

    EFFECTS OF HIGH AND LOW MANAGEMENT INTENSITY ON PROFITABILITY FOR THREE WATERMELON GENOTYPES

    Get PDF
    A replicated, small plot study on watermelon [Citrullus lanatus (Thunberg) Matsumura and Nakai] in 1997, 1999, and 2000 revealed that production management intensity affected yields and profitability of watermelon, in Oklahoma. Management intensity was based on a combination of cultural practices and levels of use of production methods. Low intensity management (LM) consisted of use of soil fertilization and weed control. High intensity management (HM) included the same weed control and fertilization as LM but also included use of plastic mulch, drip irrigation, insect pest control, and plant disease control. Cost and return analyses were based on the range of actual prices during the cropping season and the range of yields during the three years. Yields from the seedless triploid genotype 'Gem Dandy' consistently resulted in greater positive net revenue under HM than the diploid open pollinated 'Allsweet' or the hybrid diploid 'Sangria'. Under LM, yields from the seedless triploid also resulted in greater net revenues when conditions were favorable or lost less money than the open pollinated 'Allsweet' or the hybrid diploid 'Sangria' when conditions were unfavorable.Crop Production/Industries,

    Influence of Bridge Facility Attributes on Bicycle Travel Behavior

    Get PDF
    An unlabeled multinomial logit model is developed to estimate the impact bridge facility attributes have on bicycle travel behavior. Data were collected in Austin, Texas, via a GPS-based smartphone application. Three attributes are analyzed and interacted with varied demographic and trip purpose information: bridge accessibility, vehicular volume, and traffic separation. Due to the significant investment in bicycle facilities at the local, state, and federal levels and the increase in urban bicycle use, it is imperative that agencies fully understand the behavioral elements underlying bicycle travel patterns. Transportation planners cannot assume bicyclists are solely focused on minimizing travel time or distance—standard practice assumptions for vehicular modes. This paper focuses on the analysis of bridge characteristics that are attractive to bicyclists. While several others have looked at bicycle facility preferences, this is the first paper to focus exclusively on bridges. Bridge facilities are fundamentally different from the res

    Adjuvants for Leishmania vaccines: from models to clinical application

    Get PDF
    Two million new cases of leishmaniasis occur every year, with the cutaneous leishmaniasis (CL) presentation accounting for approximately two-thirds of all cases. Despite the high incidence rates and geographic expansion of the disease, CL remains a neglected tropical disease without effective intervention strategies. Efforts to address this deficit have given rise to the experimental murine model of CL. By virtue of its simplicity and pliability, the CL model has been used to provide substantial information regarding cellular immunity, as well as in the discovery and evaluation of various vaccine adjuvants. The CL model has facilitated in vivo studies of the mechanism of action of many adjuvants, including the TLR4 agonist monophosphoryl lipid A, the TLR7/8 agonist imiquimod, the TLR9 agonist CpG, adenoviral vectors, and the immunostimulatory complexes. Together, these studies have helped to unveil the requirement for certain types of immune responses at specific stages of CL disease and provide a basis to aid the design of effective second-generation vaccines for human CL. This review focuses on adjuvants that have been tested in experimental CL, outlining how they have helped advance our understanding of the disease and ultimately, how they have performed when applied within clinical trials against human CL

    Expression of KOC, S100P, mesothelin and MUC1 in pancreatico-biliary adenocarcinomas: development and utility of a potential diagnostic immunohistochemistry panel

    Get PDF
    <b>Background</b> Pancreatico-biliary adenocarcinomas (PBA) have a poor prognosis. Diagnosis is usually achieved by imaging and/or endoscopy with confirmatory cytology. Cytological interpretation can be difficult especially in the setting of chronic pancreatitis/cholangitis. Immunohistochemistry (IHC) biomarkers could act as an adjunct to cytology to improve the diagnosis. Thus, we performed a meta-analysis and selected KOC, S100P, mesothelin and MUC1 for further validation in PBA resection specimens.<p></p> <b>Methods</b> Tissue microarrays containing tumour and normal cores in a ratio of 3:2, from 99 surgically resected PBA patients, were used for IHC. IHC was performed on an automated platform using antibodies against KOC, S100P, mesothelin and MUC1. Tissue cores were scored for staining intensity and proportion of tissue stained using a Histoscore method (range, 0–300). Sensitivity and specificity for individual biomarkers, as well as biomarker panels, were determined with different cut-offs for positivity and compared by summary receiver operating characteristic (ROC) curve.<p></p> <b>Results</b> The expression of all four biomarkers was high in PBA versus normal ducts, with a mean Histoscore of 150 vs. 0.4 for KOC, 165 vs. 0.3 for S100P, 115 vs. 0.5 for mesothelin and 200 vs. 14 for MUC1 (p < .0001 for all comparisons). Five cut-offs were carefully chosen for sensitivity/specificity analysis. Four of these cut-offs, namely 5%, 10% or 20% positive cells and Histoscore 20 were identified using ROC curve analysis and the fifth cut-off was moderate-strong staining intensity. Using 20% positive cells as a cut-off achieved higher sensitivity/specificity values: KOC 84%/100%; S100P 83%/100%; mesothelin 88%/92%; and MUC1 89%/63%. Analysis of a panel of KOC, S100P and mesothelin achieved 100% sensitivity and 99% specificity if at least 2 biomarkers were positive for 10% cut-off; and 100% sensitivity and specificity for 20% cut-off.<p></p> <b>Conclusion</b> A biomarker panel of KOC, S100P and mesothelin with at least 2 biomarkers positive was found to be an optimum panel with both 10% and 20% cut-offs in resection specimens from patients with PBA.<p></p&gt

    Modification of the standard model for the lanthanides

    Full text link
    We show that incorporation of strong electron correlations into the Kohn-Sham scheme of band structure calculations leads to a modification of the standard model of the lanthanides and that this procedure removes the existing discrepancy between theory and experiment concerning the ground state properties. Within the picture suggested, part of the upper Hubbard ff-band is occupied due to conduction band-ff-mixing interaction (that is renormalized due to correlations) and this contributes to the cohesive energy of the crystal. The lower Hubbard band has zero width and describes fermionic excitations in the shell of localized ff-s. Fully self-consistent calculations (with respect to both charge density and many-electron population numbers of the ff-shell) of the equilibrium volume V0V_0 and the bulk modulus of selected lanthanides have been performed and a good agreement is obtained.Comment: 1 fi

    Randomized controlled trial of patient-controlled sedation for colonoscopy: Entonox vs modified patient-maintained target-controlled propofol

    Get PDF
    Aim Propofol sedation is often associated with deep sedation and decreased manoeuvrability. Patient-maintained sedation has been used in such patients with minimal side-effects. We aimed to compare novel modified patient-maintained target-controlled infusion (TCI) of propofol with patient-controlled Entonox inhalation for colonoscopy in terms of analgesic efficacy (primary outcome), depth of sedation, manoeuvrability and patient and endoscopist satisfaction (secondary outcomes). Method One hundred patients undergoing elective colonoscopy were randomized to receive either TCI propofol or Entonox. Patients in the propofol group were administered propofol initially to achieve a target concentration of 1.2 μ g/ml and then allowed to self-administer a bolus of propofol (200 μ g/kg/ml) using a patient-controlled analgesia pump with a handset. Entonox group patients inhaled the gas through a mouthpiece until caecum was reached and then as required. Sedation was initially given by an anaesthetist to achieve a score of 4 (Modified Observer's Assessment of Alertness and Sedation Scale), and colonoscopy was then started. Patients completed an anxiety score (Hospital Anxiety and Depression questionnaire), a baseline letter cancellation test and a pain score on a 100-mm visual analogue scale before and after the procedure. All patients completed a satisfaction survey at discharge and 24 h postprocedure. Results The median dose of propofol was 174 mg, and the median number of propofol boluses was four. There was no difference between the two groups in terms of pain recorded (95% confidence interval of the difference -0.809, 5.02) and patient/endoscopist satisfaction. There was no difference between the two groups in either depth of sedation or manoeuvrability. Conclusion Both Entonox and the modified TCI propofol provide equally effective sedation and pain relief, simultaneously allowing patients to be easily manoeuvred during the procedures. © 2010 The Authors. Colorectal Disease © 2010 The Association of Coloproctology of Great Britain and Ireland

    A case study of electron precipitation fluxes due to plasmaspheric hiss

    Get PDF
    We find that during a large geomagnetic storm in October 2011 the trapped fluxes of >30, >100, and >300 keV outer radiation belt electrons were enhanced at L=3-4 during the storm main phase. A gradual decay of the trapped fluxes was observed over the following 5–7 days, even though no significant precipitation fluxes could be observed in the Polar Orbiting Environmental Satellite (POES) electron precipitation detectors. We use the Antarctic-Arctic Radiation-belt (Dynamic) Deposition - VLF Atmospheric Research Konsortium (AARDDVARK) receiver network to investigate the characteristics of the electron precipitation throughout the storm period. Weak electron precipitation was observed on the dayside for 5–7 days, consistent with being driven by plasmaspheric hiss. Using a previously published plasmaspheric hiss-induced electron energy e-folding spectrum of E0=365 keV, the observed radiowave perturbation levels at L=3-4 were found to be caused by >30 keV electron precipitation with flux ~100 el. cm−2 s−1 sr−1. The low levels of precipitation explain the lack of response of the POES telescopes to the flux, because of the effect of the POES lower sensitivity limit and ability to measure weak diffusion-driven precipitation. The detection of dayside, inner plasmasphere electron precipitation during the recovery phase of the storm is consistent with plasmaspheric hiss wave-particle interactions, and shows that the waves can be a significant influence on the evolution of the outer radiation belt trapped flux that resides inside the plasmapause
    corecore