453 research outputs found
Happiness on Tap: Piped Water Adoption in Urban Morocco
We study the demand for household water connections in urban Morocco, and the effect of such connections on household welfare. In the northern city of Tangiers, among homeowners without a private connection to the city’s water grid, a random subset was offered a simplified procedure to purchase a household connection on credit (at a zero percent interest rate). Take-up was high, at 69%. Because all households in our sample had access to the water grid through free public taps (often located fairly close to their homes), household connections did not lead to any improvement in the quality of the water households consumed; and despite significant increase in the quantity of water consumed, we find no change in the incidence of waterborne illnesses. Nevertheless, we find that households are willing to pay a substantial amount of money to have a private tap at home. Being connected generates important time gains, which are used for leisure and social activities, rather than productive activities. Because water is often a source of tension between households, household connections improve social integration and reduce conflict. Overall, within 6 months, self-reported well-being improved substantially among households in the treatment group, despite the financial cost of the connection. Our results suggest that facilitating access to credit for households to finance lump sum quality-of-life investments can significantly increase welfare, even if those investments do not result in income or health gains
Phenomenological model for the remanent magnetization of dilute quasi-one-dimensional antiferromagnets
We present a phenomenological model for the remanent magnetization at low
temperatures in the quasi-one-dimensional dilute antiferromagnets
CH_{3}NH_{3}Mn_{1-x}Cd_{x} Cl_{3}\cdot 2H_{2}O and
(CH_{3})_{2}NH_{2}Mn_{1-x}Cd_{x}Cl_{3}\cdot 2H_{2}O. The model assumes the
existence of uncompensated magnetic moments induced in the odd-sized segments
generated along the Mn(^{2+}) chains upon dilution. These moments are further
assumed to correlate ferromagnetically after removal of a cooling field. Using
a (mean-field) linear-chain approximation and reasonable set of model
parameters, we are able to reproduce the approximate linear temperature
dependence observed for the remanent magnetization in the real compounds.Comment: 5 pages, 2 figures; final version to appear in Physical Review
AME position statement on adrenal incidentaloma.
Objective: To assess currently available evidence on adrenal incidentaloma and provide recommendations for clinical practice. Design: A panel of experts (appointed by the Italian Association of Clinical Endocrinologists (AME)) appraised the methodological quality of the relevant studies, summarized their results, and discussed the evidence reports to find consensus. Radiological assessment: Unenhanced computed tomography (CT) is recommended as the initial test with the use of an attenuation value of <= 10 Hounsfield units (HU) to differentiate between adenomas and non-adenomas. For tumors with a higher baseline attenuation value, we suggest considering delayed contrast-enhanced CT studies. Positron emission tomography (PET) or PET/CT should be considered when CT is inconclusive, whereas fine needle aspiration biopsy may be used only in selected cases suspicious of metastases (after biochemical exclusion of pheochromocytoma). Hormonal assessment: Pheochromocytoma and excessive overt cortisol should be ruled out in all patients, whereas primary aldosteronism has to be considered in hypertensive and/or hypokalemic patients. The 1 mg overnight dexamethasone suppression test is the test recommended for screening of subclinical Cushing's syndrome (SCS) with a threshold at 138 nmol/l for considering this condition. A value of 50 nmol/l virtually excludes SCS with an area of uncertainty between 50 and 138 nmol/l. Management: Surgery is recommended for masses with suspicious radiological aspects and masses causing overt catecholamine or steroid excess. Data are insufficient to make firm recommendations for or against surgery in patients with SCS. However, adrenalectomy may be considered when an adequate medical therapy does not reach the treatment goals of associated diseases potentially linked to hypercortisolism
Imaging tests in determination of brain death
In this issue, an excellent review is published on the imaging findings in non-neonatal hypoxic-ischemic encephalopathy [1]. The authors also go into detail on imaging “brain death”, an entity that is currently causing debate as far as the imaging approach is concerned. Brain death refers to the irreversible end of all brain activity due to necrosis of neurons. The diagnosis of brain death allows organ donation for transplantation or withdrawal of life support. Legal standard and/or practice guidelines are currently present in most countries. There is uniform agreement on the clinical neurological examination to evaluate absence of brain function. This examination includes the assessment of coma, the absence of brain reflexes, and the assessment of apnea. Some guidelines require a confirmatory test for the diagnosis o
Radio-frequency tissue ablation of the liver: in vivo and ex vivo experiments with four different systems.
The aim of this study was to test the efficacy of four different radio-frequency ablation (RFA) systems in normal hepatic parenchyma in large animals. The RFA was applied to pig livers in vivo and to calf livers ex vivo using the Radionics cluster needle, RITA starburst XL needle, Radiotherapeutics Le Veen 4.0 needle, and the Berchtold 14-G saline-perfused 15-mm active-tip needle based on constructor specifications. The volume of tissue coagulation from RF was calculated from measurements of the vertical diameter (Dv) and transverse diameter (Dt). Lesion shape was characterized using the ratio between Dt/Dv. Radiotherapeutics and RITA produced in vivo lesion volume of 42+/-10, 39+/-4 cm3 with a reproducible spherical shape (Dt/Dv of 1.01+/-0.16 and 0.97+/-0.1, respectively). Radionics produced in vivo RF lesions volume of 29+/-11 cm3) with an ovoid shape (Dt/Dv 0.88+/-0.09). The RF lesions with the Berchtold device could not be assessed in vivo as 5 of 8 animals died during treatment. Ex vivo RF lesions had similar volumes with each system; however, the Radiotherapeutics device produced more reproducible shaped lesions than the other systems. In our experimental study, we found no difference between expandable needle systems in vivo. Cooled needles produced slightly smaller and ovoid shape in vivo lesions
Nonlinear excitations in CsNiF3 in magnetic fields perpendicular to the easy plane
Experimental and numerical studies of the magnetic field dependence of the
specific heat and magnetization of single crystals of CsNiF3 have been
performed at 2.4 K, 2.9 K, and 4.2 K in magnetic fields up to 9 T oriented
perpendicular to the easy plane. The experimental results confirm the presence
of the theoretically predicted double peak structure in the specific heat
arising from the formation of nonlinear spin modes. The demagnetizing effects
are found to be negligible, and the overall agreement between the data and
numerical predictions is better than reported for the case when the magnetic
field was oriented in the easy plane. Demagnetizing effects might play a role
in generating the difference observed between theory and experiment in previous
work analyzing the excess specific heat using the sine-Gordon model.Comment: 6 pages, 5 figures, submitted to Phys. Rev.
Magnetization steps in a diluted Heisenberg antiferromagnetic chain: Theory and experiments on TMMC:Cd
A theory for the equilibrium low-temperature magnetization M of a diluted
Heisenberg antiferromagnetic chain is presented. The magnetization curve, M
versus B, is calculated using the exact contributions of finite chains with 1
to 5 spins, and the "rise and ramp approximation" for longer chains. Some
non-equilibrium effects that occur in a rapidly changing B, are also
considered. Specific non-equilibrium models based on earlier treatments of the
phonon bottleneck, and of spin flips associated with cross relaxation and with
level crossings, are discussed. Magnetization data on powders of TMMC diluted
with cadmium [i.e., (CH_3)_4NMn_xCd_(1-x)Cl_3, with 0.16<=x<=0.50 were measured
at 0.55 K in 18 T superconducting magnets. The field B_1 at the first MST from
pairs is used to determine the NN exchange constant, J, which changes from -5.9
K to -6.5 K as x increases from 0.16 to 0.50. The magnetization curves obtained
in the superconducting magnets are compared with simulations based on the
equilibrium theory. Data for the differential susceptibility, dM/dB, were taken
in pulsed magnetic fields (7.4 ms duration) up to 50 T, with the powder samples
in a 1.5 K liquid-helium bath. Non-equilibrium effects, which became more
severe as x decreased, were observed. The non-equilibrium effects are
tentatively interpreted using the "Inadequate Heat Flow Scenario," or to
cross-relaxation, and crossings of energy levels, including those of excited
states.Comment: 16 pages, 14 figure
Performance investigation of hybrid excited switched flux permanent magnet machines using frozen permeability method
This study investigates the electromagnetic performance of a hybrid excited switched flux permanent magnet (SFPM) machine using the frozen permeability (FP) method. The flux components due to PMs, field excitation windings and armature windings have been separated using the FP method. It has been used to separate the torque components due to the PMs and excitations, providing a powerful insight into the torque generation mechanism of hybrid excited SFPM machines. It also allows the accurate calculation of d- and q-axis inductances, which will then be used to calculate the torque, power and power factor against rotor speed to compare the relative merits of hybrid excited SFPM machines with different types of PMs (i.e. NdFeB, SmCo and Ferrite). This offers the possibility of choosing appropriate PMs for different applications (maximum torque or maximum speed). Although only one type of hybrid excited PM machine has been employed to carry out the investigations, the method used in this study can also be extended to other hybrid excited PM machines. The predicted results have been validated by tests
- …