3 research outputs found

    Wind Speed Forecast for Sudan Using the Two-Parameter Weibull Distribution: The Case of Khartoum City

    No full text
    In this quick study, we estimated the Weibull distribution’s parameters using wind data collected between March 2017 and January 2018 using a twelve-meter mast meteorological station on the grounds of the National Energy Research Center in Khartoum. In order to quantify these descriptors, we relied on analytical and stochastic methods, subsequently enabling specialists from researchers, engineers, decision-makers, and policymakers to apprehend the wind characteristics in the vicinity. Hence, the computed scale and shape parameters were provided, in which the Firefly algorithm (FA) resulted in the most accuracy in terms of the coefficient of determination, which equaled 0.999, which we considered logical due to the observed nonlinearity in the wind speed numbers. On the contrary, the energy pattern factor method had the worst prediction capability depending on several goodness-of-fit metrics. This concise work is unique because it is the first to use data from Sudan to forecast local wind speeds using artificial intelligence algorithms, particularly the FA technique, which is widely used in solar photovoltaic modeling. Additionally, since classic estimating approaches act differently spatially, evaluating their efficacy becomes innovative, which was accomplished here. On a similar note, a weighted-average wind speed was found to equal 4.98 m/s and the FA average wind speed was 3.73 m/s, while the rose diagram indicated that most winds with potential energy equivalent to 3 m/s or more blow from the north

    Performance evaluation of five commercial assays in assessing seroprevalence of HEV antibodies among blood donors

    No full text
    Although hepatitis E virus (HEV) is mainly transmitted via the faecal-oral route, the rate of HEV transmission via blood donation is on the rise. However, the seroprevalence of HEV among blood donors is not well established and is thought to be affected by the type of diagnostic assay used. We aimed to evaluate performance and correlation among widely used commercial diagnostic assays for the seroprevalence assessment of HEV-IgM/IgG among blood donors. A total of 1049 blood donor samples were tested for HEV IgG and IgM using different enzyme immunoassays (Wantai, Eruoimmune, MP diagnostics, Mikrogen immunoblot, HEV-IgM rapid test). The performance of each assay was evaluated according to our established silver standard value based on three or more IgG concordant assay results. HEV seroprevalence varied considerably using these assays, ranging from 10.1 % (Euroimmune-ELISA) to 18.0 % (Wanti-ELISA) for HEV-IgG, and from 0.2 % (Wanti-ELISA) to 2.6 % (MP Rapid test) for HEV-IgM. A total of 155 of 216 (71.6%) samples tested positive for HEV-IgG by three or more concordant assays. On the other hand, IgM assays showed poor agreement as only 7.6 % (4/52) of the specimens were positive according to three or more concordant assay test results. All HEV-IgG assays revealed high sensitivity and specificity (ranging 96.5-100 %),and excellent Kappa concordance (0.88-0.95), except for Euroimmun ELISA (sensitivity=61.5 %, kappa=0.63). MP ELISA showed the highest levels of sensitivity (100 %) and specificity (98.5 %). Due to discrepancies in the performance of various IgG and IgM assays, seroprevalence studies should be based on furher confirmatory testing for decisive conclusions to be reached
    corecore