7,780 research outputs found
Automated mass spectrometer/analysis system: A concept
System performs rapid multiple analyses of entire compound classes or individual compounds on small amounts of sample and reagent. Method will allow screening of large populations for metabolic disorders and establishment of effective-but-safe levels of therapeutic drugs in body fluids and tissues
Behavior of the Dripping Faucet over a Wide Range of the Flow Rate
The time interval of successive water-drips from a faucet was examined over a
wide range of the flow rate. The dripping interval alternately exhibits a
stable state and a chaotic state as the flow rate increases. In the stable
state, the volume of the drip is kept constant at fixed flow rates, and the
constant volume increases with the flow rate. In the chaotic state, in addition
to a mechanics that the drip is torn by its own weight, the vibration of the
drip on the faucet takes part in the strange behavior of the interval.Comment: 7 pages, 7 figures, to be published in J. Phys. Soc. Jpn vol
68-2(1999
The effect of stellar limb darkening values on the accuracy of the planet radii derived from photometric transit observations
We study how the precision of the exoplanet radius determination is affected
by our present knowledge of limb darkening in two cases: when we fix the limb
darkening coefficients and when we adjust them. We also investigate the effects
of spots in one-colour photometry. We study the effect of limb darkening on the
planetary radius determination both via analytical expressions and by numerical
experiments. We also compare some of the existing limb darkening tables. When
stellar spots affect the fit, we replace the limb darkening coefficients,
calculated for the unspotted cases, with effective limb darkening coefficients
to describe the effect of the spots. There are two important cases. (1) When
one fixes the limb darkening values according to some theoretical predictions,
the inconsistencies of the tables do not allow us to reach accuracy in the
planetary radius of better than 1-10% (depending on the impact parameter) if
the host star's surface effective temperature is higher than 5000 K. Below 5000
K the radius ratio determination may contain even 20% error. (2) When one
allows adjustment of the limb darkening coefficients, the a/Rs ratio, the
planet-to-stellar radius ratio, and the impact parameter can be determined with
sufficient accuracy (<1%), if the signal-to-noise ratio is high enough.
However, the presence of stellar spots and faculae can destroy the agreement
between the limb darkening tables and the fitted limb darkening coefficients,
but this does not affect the precision of the planet radius determination. We
also find that it is necessary to fit the contamination factor, too. We
conclude that the present inconsistencies of theoretical stellar limb darkening
tables suggests one should not fix the limb darkening coefficients. When one
allows them to be adjusted, then the planet radius, impact parameter, and the
a/Rs can be obtained with the required precision.Comment: Astronomy & Astrophysics Vol. 549, A9 (2013) - 11 page
- …