55 research outputs found

    Reliability, construct validity and measurement potential of the ICF comprehensive core set for osteoarthritis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>This study aimed to investigate the reliability and construct validity of the International Classification of Functioning, Disability and Health (ICF) Comprehensive Core Set for osteoarthritis (OA) in order to test its possible use as a measuring tool for functioning.</p> <p>Methods</p> <p>100 patients with OA (84 F, 16 M; mean age 63 yr) completed forms including demographic and clinical information besides the Short Form (36) Health Survey (SF-36<sup>®</sup>) and the Western Ontario and McMaster Universities Index of Osteoarthritis (WOMAC). The ICF Comprehensive Core Set for OA was filled by health professionals. The internal construct validities of "Body Functions-Body structures" (BF-BS), "Activity" (A), "Participation" (P) and "Environmental Factors" (EF) domains were tested by Rasch analysis and reliability by internal consistency and person separation index (PSI). External construct validity was evaluated by correlating the Rasch transformed scores with SF-36 and WOMAC.</p> <p>Results</p> <p>In each scale, some items showing disordered thresholds were rescored, testlets were created to overcome the problem of local dependency and items that did not fit to the Rasch model were deleted. The internal construct validity of the four scales (BF-BS 16 items, A 8 items, P 7 items, EF 13 items) were good [mean item fit (SD) 0.138 (0.921), 0.216 (1.237), 0.759 (0.986) and -0.079 (2.200); person item fit (SD) -0.147 (0.652), -0.241 (0.894), -0.310 (1.187) and -0.491 (1.173) respectively], indicating a single underlying construct for each scale. The scales were free of differential item functioning (DIF) for age, gender, years of education and duration of disease. Reliabilities of the BF-BS, A, P, and EF scales were good with Cronbach's alphas of 0.79, 0.86, 0.88, and 0.83 and PSI's of 0.76, 0.86, 0.87, and 0.71, respectively. Rasch scores of BF-BS, A, and P showed moderate correlations with SF-36 and WOMAC scores where the EF had significant but weak correlations only with SF36-Social Functioning and SF36-Mental Health.</p> <p>Conclusion</p> <p>Since the four different scales derived from BF-BS, A, P, and EF components of the ICF core set for OA were shown to be valid and reliable through a combination of Rasch analysis and classical psychometric methods, these might be used as clinical assessment tools.</p

    Reliability of maximal isometric knee strength testing with modified hand-held dynamometry in patients awaiting total knee arthroplasty: useful in research and individual patient settings? A reliability study

    Get PDF
    <p>Abstract</p> <p><b>Background</b></p> <p>Patients undergoing total knee arthroplasty (TKA) often experience strength deficits both pre- and post-operatively. As these deficits may have a direct impact on functional recovery, strength assessment should be performed in this patient population. For these assessments, reliable measurements should be used. This study aimed to determine the inter- and intrarater reliability of hand-held dynamometry (HHD) in measuring isometric knee strength in patients awaiting TKA.</p> <p><b>Methods</b></p> <p>To determine interrater reliability, 32 patients (81.3% female) were assessed by two examiners. Patients were assessed consecutively by both examiners on the same individual test dates. To determine intrarater reliability, a subgroup (n = 13) was again assessed by the examiners within four weeks of the initial testing procedure. Maximal isometric knee flexor and extensor strength were tested using a modified Citec hand-held dynamometer. Both the affected and unaffected knee were tested. Reliability was assessed using the Intraclass Correlation Coefficient (ICC). In addition, the Standard Error of Measurement (SEM) and the Smallest Detectable Difference (SDD) were used to determine reliability.</p> <p><b>Results</b></p> <p>In both the affected and unaffected knee, the inter- and intrarater reliability were good for knee flexors (ICC range 0.76-0.94) and excellent for knee extensors (ICC range 0.92-0.97). However, measurement error was high, displaying SDD ranges between 21.7% and 36.2% for interrater reliability and between 19.0% and 57.5% for intrarater reliability. Overall, measurement error was higher for the knee flexors than for the knee extensors.</p> <p><b>Conclusions</b></p> <p>Modified HHD appears to be a reliable strength measure, producing good to excellent ICC values for both inter- and intrarater reliability in a group of TKA patients. High SEM and SDD values, however, indicate high measurement error for individual measures. This study demonstrates that a modified HHD is appropriate to evaluate knee strength changes in TKA patient groups. However, it also demonstrates that modified HHD is not suitable to measure individual strength changes. The use of modified HHD is, therefore, not advised for use in a clinical setting.</p

    Diagnostic Value of Lumbar Facet Joint Injection: A Prospective Triple Cross-Over Study

    Get PDF
    The diagnosis “lumbar facet syndrome” is common and often indicates severe lumbar spine surgery procedures. It is doubtful whether a painful facet joint (FJ) can be identified by a single FJ block. The aim of this study was to clarify the validity of a single and placebo controlled bilateral FJ blocks using local anesthetics. A prospective single blinded triple cross-over study was performed. 60 patients (31 f, 29 m, mean age 53.2 yrs (22–73)) with chronic low back pain (mean pain persistance 31 months, 6 months of conservative treatment without success) admitted to a local orthopaedic department for surgical or conservative therapy of chronic LBP, were included in the study. Effect on pain reduction (10 point rating scale) was measured. The 60 subjects were divided into six groups with three defined sequences of fluoroscopically guided bilateral monosegmental lumbar FJ test injections in “oblique needle” technique: verum-(local anaesthetic-), placebo-(sodium chloride-) and sham-injection. Carry-over and periodic effects were evaluated and a descriptive and statistical analysis regarding the effectiveness, difference and equality of the FJ injections and the different responses was performed. The results show a high rate of non-response, which documents the lack of reliable and valid predictors for a positive response towards FJ blocks. There was a high rate of placebo reactions noted, including subjects who previously or later reacted positively to verum injections. Equivalence was shown among verum vs. placebo and partly vs. sham also. With regard to test validity criteria, a single intraarticular FJ block with local anesthetics is not useful to detect the pain-responsible FJ and therefore is no valid and reliable diagostic tool to specify indication of lumbar spine surgery. Comparative FJ blocks with local anesthetics and placebo-controls have to be interpretated carefully also, because they solely give no proper diagnosis on FJ being main pain generator

    Appropriateness Kriterien in der Hüftendoprothetik - Entwicklung und erste Erfahrungen

    No full text
    M. A. Collins' 8 wheel Foden flat lorry photographed 26 August 1959. see also 178C57.1245

    Appropriateness Kriterien in der Hüftendoprothetik - Entwicklung und erste Erfahrungen

    No full text

    Entwicklung von Notwendigkeitskriterien zur Hüftprothesenimplantation

    No full text

    EULAR/EFORT recommendations for management of patients older than 50 years with a fragility fracture and prevention of subsequent fractures

    Full text link
    The European League Against Rheumatism (EULAR) and the European Federation of National Associations of Orthopaedics and Traumatology (EFORT) have recognised the importance of optimal acute care for the patients aged 50 years and over with a recent fragility fracture and the prevention of subsequent fractures in high-risk patients, which can be facilitated by close collaboration between orthopaedic surgeons and rheumatologists or other metabolic bone experts. Therefore, the aim was to establish for the first time collaborative recommendations for these patients. According to the EULAR standard operating procedures for the elaboration and implementation of evidence-based recommendations, 7 rheumatologists, a geriatrician and 10 orthopaedic surgeons met twice under the leadership of 2 convenors, a senior advisor, a clinical epidemiologist and 3 research fellows. After defining the content and procedures of the task force, 10 research questions were formulated, a comprehensive and systematic literature search was performed and the results were presented to the entire committee. 10 recommendations were formulated based on evidence from the literature and after discussion and consensus building in the group. The recommendations included appropriate medical and surgical perioperative care, which requires, especially in the elderly, a multidisciplinary approach including orthogeriatric care. A coordinator should setup a process for the systematic investigations for future fracture risk in all elderly patients with a recent fracture. High-risk patients should have appropriate non-pharmacological and pharmacological treatment to decrease the risk of subsequent fracture. KEYWORDS: Bone Mineral Density; Orthopedic Surgery; Osteoporosi

    Burden of muscoskeletal conditions in Germany in the Bone and Joint Decade

    No full text

    Erhalten Studenten an deutschen Universitäten genügend Unterricht in Orthopädie?

    No full text

    Ergebnisse der posttraumatischen Rehabilitation bei Tetra- und Paraplegikern > 65 Jahre

    No full text
    corecore