5,580 research outputs found
On the Detectability of Oxygen X-ray Fluorescence and its Use as a Solar Photospheric Abundance Diagnostic
Monte Carlo calculations of the O Kalpha line fluoresced by coronal X-rays
and emitted just above the temperature minimum region of the solar atmosphere
have been employed to investigate the use of this feature as an abundance
diagnostic. While quite weak, we estimate line equivalent widths in the range
0.02-0.2 AA, depending on the X-ray plasma temperature. The line remains
essentially uncontaminated by blends for coronal temperatures T =< 3e6 K and
should be quite observable, with a flux >~ 2 ph/s/arcmin^2. Model calculations
for solar chemical mixtures with an O abundance adjusted up and down by a
factor of 2 indicate 35-60% changes in O Kalpha line equivalent width,
providing a potentially useful O abundance diagnostic. Sensitivity of
equivalent width to differences between recently recommended chemical
compositions with ``high'' and ``low'' complements of the CNO trio important
for interpreting helioseismological observations is less accute, amounting to
20-26% at coronal temperatures T ~< 2e6 K. While still feasible for
discriminating between these two mixtures, uncertainties in measured line
equivalent widths and in the models used for interpretation would need to be
significantly less than 20%. Provided a sensitive X-ray spectrometer with
resolving power >= 1000 and suitably well-behaved instrumental profile can be
built, X-ray fluorescence presents a viable means for resolving the solar
``oxygen crisis''.Comment: To appear in the Astrophysical Journa
QED calculation of the n=1 and n=2 energy levels in He-like ions
We perform ab initio QED calculations of energy levels for the and
states of He-like ions with the nuclear charge in the range -100.
The complete set of two-electron QED corrections is evaluated to all orders in
the parameter \aZ. Uncalculated contributions to energy levels come through
orders \alpha^3 (\aZ)^2, \alpha^2 (\aZ)^7, and higher. The calculation
presented is the first treatment for excited states of He-like ions complete
through order \alpha^2 (\aZ)^4. A significant improvement in accuracy of
theoretical predictions is achieved, especially in the high- region.Comment: 23 pages, 5 figure
Evaluation of a Coping Kit of Items to Support Children with Developmental Disorders in the Hospital Setting
This study attempted to answer the question, Do nurses perceive coping kits to be effective at meeting the needs of hospitalized children with developmental disabilities who are at increased risk for challenging behaviors? A cross-sectional post-test survey study design was used, with a convenience sample of 24 registered nurses at a Midwestern free-standing children\u27s hospital. A coping kit with simple communication cards, social script book, and distraction items (toys) was developed to enhance communication and distract children with developmental disabilities (including autism spectrum disorder) undergoing procedures in the hospital. A modified version of Hudson\u27s (2006) intervention effectiveness survey was used to measure the nurse\u27s perception of the effectiveness of the coping kit. Nurses perceived the coping kits to be effective for decreasing their patient\u27s anxiety, calming the child\u27s behavior, and increasing cooperation during procedures. The nurse can develop a plan of care that includes a coping kit to help gain cooperation with the hospitalized child with challenging behaviors
Analog processing of signals from a CZT strip detector with orthogonal coplanar anodes
We present the requirements, design, and performance of an analog circuit for processing the non-collecting anode strip signals from a cadmium zinc telluride (CZT) strip detector with orthogonal coplanar anodes. Detector signal simulations and measurements with a prototype are used to define the range of signal characteristics as a function of location of the gamma interaction in the detector. The signals from the non- collecting anode strip electrodes are used to define two of the three spatial coordinates including the depth of interaction, the z dimension. Analog signal processing options are discussed. A circuit to process the signals from the non- collecting anode strips and extract from them the depth of interaction is described. The circuit employs a time-over- threshold (TOT) measurement. The performance of the detector prototype with a preliminary version of this circuit is presented, and future development work is outlined
- …