344 research outputs found

    Do patients’ information needs decrease over the course of radiotherapy?

    Get PDF
    PURPOSE: We aimed to investigate if cancer patients’ information needs decrease during radiotherapy and if so, which patient, consultation and radiation oncologist characteristics are associated with a decrease in information needs over time. METHODS: In this longitudinal study, patients (n = 104) completed a baseline questionnaire a week before the initial radiotherapy consultation, immediately following this initial consultation, and 1 week prior to the first follow-up visit, which took place on average 3–5 weeks after the initial visit. Besides information needs, measured by the Information Preference for Radiotherapy Patients scale, the questionnaire assessed patient, consultation and radiation oncologist characteristics. RESULTS: Information needs decreased over time, but remained at a high level. Being religious, being male, having low health literacy and higher perceived involvement during the consultation were all statistically significantly associated to a decrease in information needs on specific domains (e.g. procedures or side effects). CONCLUSIONS: Cancer patients’ information needs decline between the initial consultation and the first follow-up visit, but remain high. It is therefore advised to investigate the patients’ information needs at every radiotherapy visit and not rely on giving information just once. Furthermore, radiation oncologists should check if the information given at first consultation is understood and remembered. By those means, tailored information giving becomes possible

    Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength

    Get PDF
    BACKGROUND: The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to monitor changes over time, instruments and procedures with a sufficient reliability are needed. The Q Force is an innovative mobile muscle strength measurement instrument suitable to measure in various degrees of extension. Measurements between 110 and 130° extension present the highest values and the most significant increase after training. The objective of this study is to determine the test-retest reliability of muscle strength measurements by the Q Force in older adults in 110° extension. METHODS: Forty-one healthy older adults, 13 males and 28 females were included in the study. Mean (SD) age was 81.9 (4.89) years. Isometric muscle strength of the Quadriceps muscle was assessed with the Q Force at 110° of knee extension. Participants were measured at two sessions with a three to eight day interval between sessions. To determine relative reliability, the intraclass correlation coefficient (ICC) was calculated. To determine absolute reliability, Bland and Altman Limits of Agreement (LOA) were calculated and t-tests were performed. RESULTS: Relative reliability of the Q Force is good to excellent as all ICC coefficients are higher than 0.75. Generally a large 95 % LOA, reflecting only moderate absolute reliability, is found as exemplified for the peak torque left leg of -18.6 N to 33.8 N and the right leg of -9.2 N to 26.4 N was between 15.7 and 23.6 Newton representing 25.2 % to 39.9 % of the size of the mean. Small systematic differences in mean were found between measurement session 1 and 2. CONCLUSION: The present study shows that the Q Force has excellent relative test-retest reliability, but limited absolute test-retest reliability. Since the Q Force is relatively cheap and mobile it is suitable for application in various clinical settings, however, its capability to detect changes in muscle force over time is limited but comparable to existing instruments

    Lower leukotriene C4 levels in bronchoalveolar lavage fluid of asthmatic subjects after 2.5 years of inhaled corticosteroid therapy

    Get PDF
    Long-term treatment with inhaled corticosteroids has been shown to result in improvement of symptoms and lung function in subjects with asthma. Arachidonic acid (AA) metabolites are thought to play a role in the pathophysiology of asthma. It was assessed whether differences could be found in bronchoalveolar lavage (BAL) AA metabolite levels between subjects with asthma who were treated for 2.5 years with inhaled bronchodilators alone or in combination with inhaled corticosteroids. Prostaglandin (PG)D2, PGF2α, 6-keto-PGF1α, thromboxane B2, leukotriene (LT)C4 and LTB4 levels and cell numbers were assessed in BAL fluid from 22 non-smoking asthmatic subjects. They were participating in a randomized, double-blind multicentre drug trial over a period of 2.5 years. Results of the group treated with inhaled corticosteroids (CS+: beclomethasone 200 ÎŒg four times daily) were compared with the other group (CS−) which was treated with either ipratropium bromide (40 ÎŒg four times daily) or placebo. BAL LTC4 levels of asthmatic subjects were significantly lower after 2.5 years inhaled corticosteroid therapy (CS+, 9(1–17) pg/ml vs. CS−, 16(6-53) pg/ml; p = 0.01). The same trend was observed for the PGD2 levels. The results suggest that inhaled corticosteroids may exert their beneficial effect on lung function via a mechanism in which inhibition of LTC4 synthesis in the airways is involved

    Quantification of Movement in Stroke Patients under Free Living Conditions Using Wearable Sensors:A Systematic Review

    Get PDF
    Stroke is a main cause of long-term disability worldwide, placing a large burden on individuals and health care systems. Wearable technology can potentially objectively assess and monitor patients outside clinical environments, enabling a more detailed evaluation of their impairment and allowing individualization of rehabilitation therapies. The aim of this review is to provide an overview of setups used in literature to measure movement of stroke patients under free living conditions using wearable sensors, and to evaluate the relation between such sensor-based outcomes and the level of functioning as assessed by existing clinical evaluation methods. After a systematic search we included 32 articles, totaling 1076 stroke patients from acute to chronic phases and 236 healthy controls. We summarized the results by type and location of sensors, and by sensor-based outcome measures and their relation with existing clinical evaluation tools. We conclude that sensor-based measures of movement provide additional information in relation to clinical evaluation tools assessing motor functioning and both are needed to gain better insight in patient behavior and recovery. However, there is a strong need for standardization and consensus, regarding clinical assessments, but also regarding the use of specific algorithms and metrics for unsupervised measurements during daily life

    A Dutch consensus statement on the diagnosis and treatment of ANCA-associated vasculitis

    Get PDF
    INTRODUCTION: Despite the availability of several guidelines on the diagnosis and treatment of antineutrophil cytoplasmic antibody-associated vasculitis (AAV), clinical routine practice will only improve when an implementation strategy is in place to support clinical decision making and adequate implementation of guidelines. We describe here an initiative to establish national and multidisciplinary consensus on broad aspects of the diagnosis and treatment of AAV relevant to daily clinical practice in the Netherlands. METHODS: A multidisciplinary working group of physicians in the Netherlands with expertise on AAV addressed the broad spectrum of diagnosis, terminology, and immunosuppressive and non-immunosuppressive treatment, including an algorithm for AAV patients. Based on recommendations from (inter)national guidelines, national consensus was established using a Delphi-based method during a conference in conjunction with a nationally distributed online consensus survey. Cut-off for consensus was 70% (dis)agreement. RESULTS: Ninety-eight professionals were involved in the Delphi procedure to assess consensus on 50 statements regarding diagnosis, treatment, and organisation of care for AAV patients. Consensus was achieved for 37/50 statements (74%) in different domains of diagnosis and treatment of AAV including consensus on the treatment algorithm for AAV. CONCLUSION: We present a national, multidisciplinary consensus on a diagnostic strategy and treatment algorithm for AAV patients as part of the implementation of (inter)national guideline-derived recommendations in the Netherlands. Future studies will focus on evaluating local implementation of treatment protocols for AAV, and assessments of current and future clinical practice variation in the care for AAV patients in the Netherlands

    Rasiowa–Sikorski deduction systems in computer science applications

    Get PDF
    AbstractA Rasiowa-Sikorski system is a sequence-type formalization of logics. The system uses invertible decomposition rules which decompose a formula into sequences of simpler formulae whose validity is equivalent to validity of the original formula. There may also be expansion rules which close indecomposable sequences under certain properties of relations appearing in the formulae, like symmetry or transitivity. Proofs are finite decomposition trees with leaves having “fundamental”, valid labels. The author describes a general method of applying the R-S formalism to develop complete deduction systems for various brands of C.S and A.I. logic, including a logic for reasoning about relative similarity, a three-valued software specification logic with McCarthy's connectives and Kleene quantifiers, a logic for nondeterministic specifications, many-sorted FOL with possibly empty carriers of some sorts, and a three-valued logic for reasoning about concurrency
    • 

    corecore