23 research outputs found
Durability of mitral valve reconstruction using the cosgrove edwards annuloplasty band at 5 years : From 23rd World Congress of the World Society of Cardio-Thoracic Surgeons. Split, Croatia. 12-15 September 2013
Oral presentation: 23rd World Congress of the World Society of Cardio-Thoracic Surgeons. Split, Croatia. 12-15 September 2013.
Background: In the past, questions have been raised, whether an open flexible annuloplasty band can reliably prevent recurrent mitral valve regurgitation. The purpose of this study was to evaluate the durability of mitral valve repair at midterm, using the Cosgrove-Edwards annuloplasty band in a homogenic patient cohort.
Methods: From January 2004 to December 2007, 157 consecutive patients with degenerative mitral valve disease were included in the study. All had quadrangular resection of a P2 prolapse and annuloplasty with a Cosgrove-Edwards annuloplasty band. Clinical and echocardiography follow-up was complete.
Results: There was no intraoperative or 30 day mortality. After a mean follow-up of 5.0 ± 1.9 years, survival was 94.3%. At midterm, freedom from reoperations was 98.9%, freedom from thromboembolism was 97.5% and freedom from endocarditis was 99.4%. Echocardiography follow-up showed recurrent mitral valve regurgitation higher than grade 2 in two patients. Mean ejection fraction was 60.3 ± 10.2%, left atrial diameter was 42 ± 7 mm, mean gradient was 3.2 ± 1.4 mmHg, effective orifice area was 3.3 ± 1.3cm², mitral leaflet coaptation length was 7.5 ± 1.9 mm and mitral leaflet tethering height was 6.2 ± 2.3 mm.
Conclusion: Mitral valve repair using the Cosgrove annuloplasty band for degenerative mitral valve disease provides an effective and durable form of reconstruction
Comparative evaluation of left ventricular mass regression after aortic valve replacement: a prospective randomized analysis
Background: We assessed the hemodynamic performance of various prostheses and the clinical outcomes after aortic valve replacement, in different age groups.
Methods: One-hundred-and-twenty patients with isolated aortic valve stenosis were included in this prospective randomized randomised trial and allocated in three age-groups to receive either pulmonary autograft (PA, n = 20) or mechanical prosthesis (MP, Edwards Mira n = 20) in group 1 (age 75). Clinical outcomes and hemodynamic performance were evaluated at discharge, six months and one year.
Results: In group 1, patients with PA had significantly lower mean gradients than the MP (2.6 vs. 10.9 mmHg, p = 0.0005) with comparable left ventricular mass regression (LVMR). Morbidity included 1 stroke in the PA population and 1 gastrointestinal bleeding in the MP subgroup. In group 2, mean gradients did not differ significantly between both populations (7.0 vs. 8.9 mmHg, p = 0.81). The rate of LVMR and EF were comparable at 12 months; each group with one mortality. Morbidity included 1 stroke and 1 gastrointestinal bleeding in the stentless and 3 bleeding complications in the MP group. In group 3, mean gradients did not differ significantly (7.8 vs 6.5 mmHg, p = 0.06). Postoperative EF and LVMR were comparable. There were 3 deaths in the stented group and no mortality in the stentless group. Morbidity included 1 endocarditis and 1 stroke in the stentless compared to 1 endocarditis, 1 stroke and one pulmonary embolism in the stented group.
Conclusions: Clinical outcomes justify valve replacement with either valve substitute in the respective age groups. The PA hemodynamically outperformed the MPs. Stentless valves however, did not demonstrate significantly superior hemodynamics or outcomes in comparison to stented bioprosthesis or MPs
Long-term discontinuation of warfarin in a patient with HeartMate 3 left ventricular assist device without thromboembolic events
The gold standard therapy for end-stage heart failure is cardiac transplantation. However, in the face of a donor shortage, a mechanical assist device such as the left ventricular assist device HeartMate 3 (Abbott Laboratories, Abbott Park, IL, USA) serves as bridging therapy to transplantation and/or destination therapy. Current guidelines recommend anticoagulation with a vitamin K antagonist in combination with low-dose aspirin. We herein report a challenging anticoagulation regimen in a patient with a HeartMate 3 in whom systemic anticoagulation with warfarin was not feasible for 4 years because of low compatibility and a rare X-factor deficiency. This is a rare hematological disorder, estimated to affect approximately 1 in every 500,000 to 1,000,000 people in the general population. The patient finally received a modified anticoagulation regimen involving the combination of rivaroxaban and clopidogrel without warfarin. Under this regimen, the patient remained free of thromboembolic complications for 4 years with in situ placement of the left ventricular assist device. This case illustrates that under specific circumstances, long-term absence of warfarin therapy is feasible in patients with a HeartMate 3
Propensity matched analysis of longterm outcomes following transcatheter based aortic valve implantation versus classic aortic valve replacement in patients with previous cardiac surgery
Background: The aim of this study was to compare outcome of patients with previous cardiac surgery undergoing transapical aortic valve implantation (Redo-TAVI) to those undergoing classic aortic valve replacement (Redo-AVR) by using propensity analysis.
Methods: From January 2005 through May 2012, 52 high-risk patients underwent Redo-TAVI using a pericardial xenograft fixed within a stainless steel, balloon-expandable stent (Edwards SAPIEN™). During the same period of time 167 patients underwent classic Redo-AVR. Logistic regression analysis was used to identify covariates among 11 baseline patient variables including the type of initial surgery. Using the significant regression coefficients, each patient’s propensity score was calculated, allowing selectively matched subgroups of 40 patients each. Initial surgery included coronary artery bypass grafting in 30 patients, aortic valve replacement in 7 patients and mitral valve reconstruction in 3 patients in each group. Follow-up was 4 ± 2 years and was 100% complete.
Results: Postoperative chest tube drainage (163 ± 214 vs. 562 ± 332 ml/24 h, p = 0.02) and incidence of early permanent neurologic deficit (0 vs. 13%, p = 0.04) was lower in patients with Redo-TAVI and there was a trend towards improved 30-day survival (p = 0.06). Also we detected a decreased ventilation time (p = 0.04) and lower transfusion rate of allogenic blood products (p ≤ 0.05) in the Redo-TAVI group. At late follow up differences regarding incidence of major adverse events, including death and permanent neurologic deficits (25% vs. 43%, p = 0.01) statistically supported early postoperative findings.
Conclusion: The encouraging results regarding early and long-term outcomes following TAVI in patients with previous cardiac surgery show, that this evolving approach may be particularly beneficial in this patient cohort
Clinical performance of a sutureless aortic bioprosthesis: five-year results of the 3f Enable long-term follow-up study.
OBJECTIVE
Sutureless valves are designed to facilitate surgical implantation, including less-invasive techniques in aortic valve replacement, by maintaining surgical precision of implantation compared with transcatheter techniques. Long-term clinical experience with sutureless valves is lacking. We report the 5-year follow-up results of an international, prospective, multicenter study evaluating the clinical performance and safety of the 3f Enable valve (Medtronic Inc, Minneapolis, Minn).
METHODS
Between March 2007 and December 2009, 141 patients (54 male; mean age, 76.1±5.7 years) undergoing aortic valve replacement with the 3f Enable valve were enrolled in 10 European sites. The mean follow-up was 2.76 years (range, 2 days to 5.1 years; total, 388.7 patient-years). Echocardiographic valvular hemodynamic and morphologic analyses were performed by an independent core laboratory.
RESULTS
The mean systolic gradient was 10.4±4.4 mm Hg at discharge and 7.7±4.1 mm Hg at 5 years. The mean effective orifice area was 1.7±0.5 cm2 at discharge and 1.6±0.2 cm2 at 5 years. Freedom from all-cause and valve-related mortality was 87.6%±2.9% and 96.8%±1.6% at 1 year (113 patients at risk) and 77.0%±7.5% and 93.8%±4.8% at 5 years (24 patients at risk), respectively. Six patients underwent reoperation (4 because of major paravalvular leakage and 2 because of endocarditis). Freedom from reoperation was 95.4%±1.9% at 1 year and 95.4%±6.1% at 5 years. No structural valve deterioration occurred during the follow-up period.
CONCLUSIONS
The sutureless 3f Enable valve represents a safe and effective treatment for aortic valve stenosis, providing an excellent hemodynamic profile. This study represents the longest follow-up study for a sutureless bioprosthesis. Sutureless valves may become an option for all patients with indicated biological aortic valve replacement
Outcome of patients with heart failure after transcatheter aortic valve implantation
Aims: Patients with aortic stenosis (AS) may have concomitant heart failure (HF) that determines prognosis despite successful transcatheter aortic valve implantation (TAVI). We compared outcomes of TAVI patients with low stroke volume index (SVI) ≤35 ml/m2 body surface area in different HF classes.
Methods and results: Patients treated by transfemoral TAVI at our center (n = 1822) were classified as 1) ‘HF with preserved ejection fraction (EF)’ (HFpEF, EF ≥50%), 2) ‘HF with mid-range EF’ (HFmrEF, EF 40–49%), or 3) ‘HF with reduced EF’ (HFrEF, EF 35 ml/m2 served as controls. The prevalence of cardiovascular disease and symptoms increased stepwise from controls (n = 968) to patients with HFpEF (n = 591), HFmrEF (n = 97), and HFrEF (n = 166). Mortality tended to be highest in HFrEF patients 30 days post-procedure, and it became significant after one year: 10.2% (controls), 13.5% (HFpEF), 13.4% (HFmrEF), and 23.5% (HFrEF). However, symptomatic improvement in survivors of all groups was achieved in the majority of patients without differences among groups.
Conclusions: Patients with AS and HF benefit from TAVI with respect to symptom alleviation. TAVI in patients with HFpEF and HFmrEF led to an identical, favorable post-procedural prognosis that was significantly better than that of patients with HFrEF, which remains a high-risk population
Outcome of patients with heart failure after transcatheter aortic valve implantation.
AIMS:Patients with aortic stenosis (AS) may have concomitant heart failure (HF) that determines prognosis despite successful transcatheter aortic valve implantation (TAVI). We compared outcomes of TAVI patients with low stroke volume index (SVI) ≤35 ml/m2 body surface area in different HF classes. METHODS AND RESULTS:Patients treated by transfemoral TAVI at our center (n = 1822) were classified as 1) 'HF with preserved ejection fraction (EF)' (HFpEF, EF ≥50%), 2) 'HF with mid-range EF' (HFmrEF, EF 40-49%), or 3) 'HF with reduced EF' (HFrEF, EF 35 ml/m2 served as controls. The prevalence of cardiovascular disease and symptoms increased stepwise from controls (n = 968) to patients with HFpEF (n = 591), HFmrEF (n = 97), and HFrEF (n = 166). Mortality tended to be highest in HFrEF patients 30 days post-procedure, and it became significant after one year: 10.2% (controls), 13.5% (HFpEF), 13.4% (HFmrEF), and 23.5% (HFrEF). However, symptomatic improvement in survivors of all groups was achieved in the majority of patients without differences among groups. CONCLUSIONS:Patients with AS and HF benefit from TAVI with respect to symptom alleviation. TAVI in patients with HFpEF and HFmrEF led to an identical, favorable post-procedural prognosis that was significantly better than that of patients with HFrEF, which remains a high-risk population
Impact of Initial Operative Urgency on Short-Term Outcomes in Patients Treated with ECMO Due to Postcardiotomy Cardiogenic Shock
The outcomes of patients with PCS and following ECMO therapy are associated with several preoperative risk factors. Our aim was to compare clinical presentation, ECMO-related data and in-hospital outcomes of patients treated with ECMO due to PCS after cardiac surgery, in regard to elective or emergent cardiac surgery procedures. Between April 2006 and October 2016, 164 consecutive patients that received VA-ECMO therapy due to PCS were identified and included in this retrospective cohort study. The patients were divided into groups based on the urgency of the initial procedures performed: elective group (ELG; n = 95) and an emergency group (EMG; n = 69). To compare the unequal patient groups, a propensity score-based matching (PSM) was applied (ELG, n = 56 vs. EMG, n = 56). The EMG primarily received ECMO intraoperatively (p ≤ 0.001). In contrast, the ELG were needed ECMO support more frequently postoperatively (p < 0.001). In-hospital mortality accounted for 71% (n = 40) in the ELG and 76% (n = 43) in the EMG (p = 0.518). Outcome data showed no major differences in the (abdominal ischemia (p = 0.371); septic shock (p = 0.393): rhythm disturbances (p = 0.575); emergency re-thoracotomy (p = 0.418)) between the groups. The urgency of the initial procedures performed is secondary in patients suffering PCS and following ECMO. In this regard, PCS itself seems to trigger outcomes in cardiac surgery ECMO patients substantially