13 research outputs found

    Influence of Role Models and Hospital Design on the Hand Hygiene of Health-Care Workers

    Get PDF
    We assessed the effect of medical staff role models and the number of health-care worker sinks on hand-hygiene compliance before and after construction of a new hospital designed for increased access to handwashing sinks. We observed health-care worker hand hygiene in four nursing units that provided similar patient care in both the old and new hospitals: medical and surgical intensive care, hematology/oncology, and solid organ transplant units. Of 721 hand-hygiene opportunities, 304 (42%) were observed in the old hospital and 417 (58%) in the new hospital. Hand-hygiene compliance was significantly better in the old hospital (161/304; 53%) compared to the new hospital (97/417; 23.3%) (p<0.001). Health-care workers in a room with a senior (e.g., higher ranking) medical staff person or peer who did not wash hands were significantly less likely to wash their own hands (odds ratio 0.2; confidence interval 0.1 to 0.5); p<0.001). Our results suggest that health-care worker hand-hygiene compliance is influenced significantly by the behavior of other health-care workers. An increased number of hand-washing sinks, as a sole measure, did not increase hand-hygiene compliance

    Performance of the BD GeneOhm Methicillin-Resistant Staphylococcus aureus Test before and during High-Volume Clinical Useâ–¿

    No full text
    We evaluated the use of the BD GeneOhm MRSA real-time PCR assay (BD Diagnostics, San Diego, CA) for the detection of nasal colonization with methicillin-resistant Staphylococcus aureus (MRSA). The initial evaluation consisted of 403 paired nasal swabs and was done using the specimen preparation provided with the kit and an in-house lysis method that was specifically developed to accommodate large-volume testing using a minimal amount of personnel time. One swab was placed in an achromopeptidase (ACP) lysis solution, and the other was first used for culture and then prepared according to the kit protocol. PCR was performed on both lysates, and results were compared to those for culture. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the PCR assay were 98%, 96%, 77%, and 99.7% with the kit lysate and 98%, 95%, 75%, and 99.7% with the ACP lysate (P, not significant), respectively. The second evaluation was done after implementation of all-admission surveillance using PCR with ACP lysis and a sampling of 1,107 PCR-negative samples and 215 PCR-positive samples that were confirmed by culture. The results of this sampling showed an NPV of 99.9% and a PPV of 73.5% (prevalence, 6%), consistent with our initial findings. The BD GeneOhm MRSA assay is an accurate and rapid way to detect MRSA nasal colonization. When one is dealing with large specimen numbers, the ACP lysis method offers easier processing without negatively affecting the sensitivity or specificity of the PCR assay

    Staphylococcus aureus Nasal Decolonization in Joint Replacement Surgery Reduces Infection

    No full text
    Surgical site infections (SSIs) with Staphylococcus aureus are a recognized adverse event of hip and knee replacements. We evaluated the impact of a program to detect S. aureus nasal carriers before surgery with preoperative decolonization (using mupirocin twice daily for 5 days prior to surgery) of carriers. Nasal swab samples were obtained from patients prior to surgery from 8/1/2003 through 2/28/2005. Samples were tested using real-time PCR technology to detect S. aureus. The group that developed S. aureus SSI was compared to a combined concurrent and historical control for one year following the operation. S. aureus caused 71% of SSIs in the combined control groups. Of the 1495 surgical candidates evaluated, 912 (61.0%) were screened for S. aureus; 223 of those screened (24.5%) were positive and then decolonized with mupirocin. Among the 223 positive and decolonized patients, three (1.3%) developed a SSI. Among the 689 screen-negative patients, four (0.6%) developed SSIs for an overall rate of 0.77%. Among the 583 control patients who were not screened or decolonized, 10 (1.7%) developed S. aureus SSIs. SSIs from other organisms were 0.44% and 0.69%, respectively
    corecore