50 research outputs found

    Functional MRI brain imaging studies using the Contact Heat Evoked Potential Stimulator (CHEPS) in a human volunteer topical capsaicin pain model

    Get PDF
    Acute application of topical capsaicin produces spontaneous burning and stinging pain similar to that seen in some neuropathic states, with local hyperalgesia. Use of capsaicin applied topically or injected intradermally has been described as a model for neuropathic pain, with patterns of activation in brain regions assessed using functional magnetic resonance imaging (fMRI) and positron emission tomography. The Contact Heat Evoked Potential Stimulator (CHEPS) is a noninvasive clinically practical method of stimulating cutaneous A-delta nociceptors. In this study, topical capsaicin (1%) was applied to the left volar forearm for 15 minutes of twelve adult healthy human volunteers. fMRI scans and a visual analog pain score were recorded during CHEPS stimulation precapsaicin and postcapsaicin application. Following capsaicin application there was a significant increase in visual analog scale (mean ± standard error of the mean; precapsaicin 26.4 ± 5.3; postcapsaicin 48.9 ± 6.0; P < 0.0001). fMRI demonstrated an overall increase in areas of activation, with a significant increase in the contralateral insular signal (mean ± standard error of the mean; precapsaicin 0.434 ± 0.03; postcapsaicin 0.561 ± 0.07; P = 0.047). The authors of this paper recently published a study in which CHEPS-evoked A-delta cerebral potential amplitudes were found to be decreased postcapsaicin application. In patients with neuropathic pain, evoked pain and fMRI brain responses are typically increased, while A-delta evoked potential amplitudes are decreased. The protocol of recording fMRI following CHEPS stimulation after topical application of capsaicin could be combined with recording of evoked potentials to provide a simple, rapid, and robust volunteer model to develop novel drugs for neuropathic pain

    How have advances in CT dosimetry software impacted estimates of CT radiation dose and cancer incidence? A comparison of CT dosimetry software: Implications for past and future research

    Get PDF
    Objective: Organ radiation dose from a CT scan, calculated by CT dosimetry software, can be combined with cancer risk data to estimate cancer incidence resulting from CT exposure. We aim to determine to what extent the use of improved anatomical representation of the adult human body “phantom” in CT dosimetry software impacts estimates of radiation dose and cancer incidence, to inform comparison of past and future research. Methods: We collected 20 adult cases for each of three CT protocols (abdomen/pelvis, chest and head) from each of five public hospitals (random sample) (January-April inclusive 2010) and three private clinics (self-report). Organ equivalent and effective dose were calculated using both ImPACT (mathematical phantom) and NCICT (voxelised phantom) software. Bland- Altman plots demonstrate agreement and Passing-Bablok regression reports systematic, proportional or random differences between results. We modelled the estimated lifetime attributable risk of cancer from a single exposure for each protocol, using age-sex specific risk-coefficients from the Biologic Effects of Ionizing Radiation VII report. Results: For the majority of organs used in epidemiological studies of cancer incidence, the NCICT software (voxelised) provided higher dose estimates. Across the lifespan NCICT resulted in cancer estimates 2.9%-6.6% and 14.8%-16.3% higher in males and females (abdomen/pelvis) and 7.6%-19.7% and 12.9%-26.5% higher in males and females respectively (chest protocol). For the head protocol overall cancer estimates were lower for NCICT, but with greatest disparity, \u3e30% at times. Conclusion: When the results of previous studies estimating CT dose and cancer incidence are compared to more recent, or future, studies the dosimetry software must be considered. Any change in radiation dose or cancer risk may be attributable to the software and phantom used, rather than—or in addition to—changes in scanning practice. Studies using dosimetry software to estimate radiation dose should describe software comprehensively to facilitate comparison with past and future research

    The International Grid (iGrid): Empowering Global Research Community Networking Using High Performance International Internet Services

    Get PDF
    The Electronic Visualization Laboratory (EVL) at the University of Illinois at Chicago and Indiana University collaborated on a major research demonstration at the IEEE/ACM Supercomputing '98 (SC'98) conference in Orlando, Florida, November 7-13, 1998, to showcase the evolution and importance of global research community networking. Collaborators worked together to solve complex computational problems using advanced high-speed networks to access geographically-distributed computing, storage, and display resources. It is the collection of computing and communication resources that we refer to as the International Grid (iGrid). This paper presents an overview of the grid testbed, some of the underlying technologies used to enable distributed computing and collaborative problem solving, and descriptions of the applications. It concludes with recommendations for the future of global research community networking, based on the experiences of iGrid participants from the USA, Australia, Canada, Germany, Japan, The Netherlands, Russia, Switzerland, Singapore, and Taiwan

    Contact heat evoked potentials using simultaneous EEG and fMRI and their correlation with evoked pain

    Get PDF
    BACKGROUND: The Contact Heat Evoked Potential Stimulator (CHEPS) utilises rapidly delivered heat pulses with adjustable peak temperatures to stimulate the differential warm/heat thresholds of receptors expressed by Adelta and C fibres. The resulting evoked potentials can be recorded and measured, providing a useful clinical tool for the study of thermal and nociceptive pathways. Concurrent recording of contact heat evoked potentials using electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI) has not previously been reported with CHEPS. Developing simultaneous EEG and fMRI with CHEPS is highly desirable, as it provides an opportunity to exploit the high temporal resolution of EEG and the high spatial resolution of fMRI to study the reaction of the human brain to thermal and nociceptive stimuli. METHODS: In this study we have recorded evoked potentials stimulated by 51° C contact heat pulses from CHEPS using EEG, under normal conditions (baseline), and during continuous and simultaneous acquisition of fMRI images in ten healthy volunteers, during two sessions. The pain evoked by CHEPS was recorded on a Visual Analogue Scale (VAS). RESULTS: Analysis of EEG data revealed that the latencies and amplitudes of evoked potentials recorded during continuous fMRI did not differ significantly from baseline recordings. fMRI results were consistent with previous thermal pain studies, and showed Blood Oxygen Level Dependent (BOLD) changes in the insula, post-central gyrus, supplementary motor area (SMA), middle cingulate cortex and pre-central gyrus. There was a significant positive correlation between the evoked potential amplitude (EEG) and the psychophysical perception of pain on the VAS. CONCLUSION: The results of this study demonstrate the feasibility of recording contact heat evoked potentials with EEG during continuous and simultaneous fMRI. The combined use of the two methods can lead to identification of distinct patterns of brain activity indicative of pain and pro-nociceptive sensitisation in healthy subjects and chronic pain patients. Further studies are required for the technique to progress as a useful tool in clinical trials of novel analgesics

    Increasing use of CT requested by emergency department physicians in tertiary hospitals in Western Australia 2003–2015: an analysis of linked administrative data

    No full text
    Objective This study aimed to examine trends in number of CT scans requested by tertiary emergency department (ED) physicians in Western Australia (WA) from 2003 to 2015 across broad demographic and presentation characteristics, anatomical areas and presented symptoms.Design An observational cross-sectional study over study period from 2003 to 2015.Setting Linked administrative health service data at individual level from WA.Participants A total of 1 666 884 tertiary hospital ED presentations of people aged 18 years or older were included in this studyMain outcome measure Number of CT scans requested by tertiary ED physicians in an ED presentation.Methods Poisson regression models were used to assess variation and trends in number of CT scans requested by ED physicians across demographic characteristics, clinical presentation characteristics and anatomical areas.Results Over the entire study duration, 71 per 1000 ED episodes had a CT requested by tertiary ED physicians. Between 2003 and 2015, the rate of CT scanning almost doubled from 58 to 105 per 1000 ED presentations. After adjusted for all observed characteristics, the rate of CT scans showed a downward trend from 2009 to 2011 and subsequent increase. Males, older individuals, those attending ED as a result of pain, those with neurological symptoms or injury or with higher priority triage code were the most likely to have CT requested by tertiary ED physicians.Conclusions Noticeable changes in the number of CTs requested by tertiary ED physicians corresponded to the time frame of major health reforms happening within WA and nationally
    corecore