5 research outputs found

    УПРАВЛІННЯ ОБОРОТНИМИ АКТИВАМИ В УМОВАХ КРИЗОВОГО СТАНУ ПІДПРИЄМСТВА

    Get PDF
    Визначено основні критерії вибору ефективного методу управління оборотними активами на основі підходів формування та фінансування оборотних активів у забезпеченні фінансової стійкості та платоспроможності промислового підприємства в кризовий період. Certainly basic criteria of choice of effective method of management of circulating assets on the basis of approaches of forming and financing of circulating assets, in providing of financial firmness and solvency of industrial enterprise in a crisis period

    Solulin reduces infarct volume and regulates gene-expression in transient middle cerebral artery occlusion in rats

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Thrombolysis after acute ischemic stroke has only proven to be beneficial in a subset of patients. The soluble recombinant analogue of human thrombomodulin, Solulin, was studied in an <it>in vivo </it>rat model of acute ischemic stroke.</p> <p>Methods</p> <p>Male SD rats were subjected to 2 hrs of transient middle cerebral artery occlusion (tMCAO). Rats treated with Solulin intravenously shortly before reperfusion were compared to rats receiving normal saline i.v. with respect to infarct volumes, neurological deficits and mortality. Gene expression of IL-6, IL-1β, TNF-α, MMP-9, CD11B and GFAP were semiquantitatively analyzed by rtPCR of the penumbra.</p> <p>Results</p> <p>24 hrs after reperfusion, rats were neurologically tested, euthanized and infarct volumes determined. Solulin significantly reduced mean total (p = 0.001), cortical (p = 0.002), and basal ganglia (p = 0.036) infarct volumes. Hippocampal infarct volumes (p = 0.191) were not significantly affected. Solulin significantly downregulated the expression of IL-1β (79%; p < 0.001), TNF-α (59%; p = 0.001), IL-6 (47%; p = 0.04), and CD11B (49%; p = 0.001) in the infarcted cortex compared to controls.</p> <p>Conclusions</p> <p>Solulin reduced mean total, cortical and basal ganglia infarct volumes and regulated a subset of cytokines and proteases after tMCAO suggesting the potency of this compound for therapeutic interventions.</p

    High CSF thrombin concentration and activity is associated with an unfavorable outcome in patients with intracerebral hemorrhage.

    No full text
    BackgroundThe cerebral thrombin system is activated in the early stage after intracerebral hemorrhage (ICH). Expression of thrombin leads to concentration dependent secondary neuronal damage and detrimental neurological outcome. In this study we aimed to investigate the impact of thrombin concentration and activity in the cerebrospinal fluid (CSF) of patients with ICH on clinical outcome.MethodsPatients presenting with space-occupying lobar supratentorial hemorrhage requiring extra-ventricular drainage (EVD) were included in our study. The CSF levels of thrombin, its precursor prothrombin and the Thrombin-Antithrombin complex (TAT) were measured using enzyme linked immune sorbent assays (ELISA). The oxidative stress marker Superoxide dismutase (SOD) was assessed in CSF. Initial clot size and intraventricular hemorrhage (IVH) volume was calculated based on by computerized tomography (CT) upon admission to our hospital. Demographic data, clinical status at admission and neurological outcome were assessed using the modified Rankin Scale (mRS) at 6-weeks and 6-month after ICH.ResultsTwenty-two consecutive patients (9 females, 11 males) with supratentorial hemorrhage were included in this study. CSF concentrations of prothrombin (p ConclusionIn this study we found that initial thrombin concentration and activity in CSF of ICH patients did not correlate with ICH and IVH volume but are associated with a poorer functional neurological outcome. These findings support mounting evidence of the role of thrombin as a contributor to secondary injury formation after ICH

    Evaluation of robot-guided minimally invasive implantation of 2067 pedicle screws

    No full text
    OBJECTIVE Recent studies have investigated the role of spinal image guidance for pedicle screw placement. Many authors have observed an elevated placement accuracy and overall improvement of outcome measures. This study assessed a bi-institutional experience following introduction of the Renaissance miniature robot for spinal image guidance in Europe. METHODS The medical records and radiographs of all patients who underwent robot-guided implantation of spinal instrumentation using the novel system (between October 2011 and March 2015 in Mainz and February 2014 and February 2016 in Regensburg) were reviewed to determine the efficacy and safety of the newly introduced robotic system. Screw position accuracy, complications, exposure durations to intraoperative radiation, and reoperation rate were assessed. RESULTS Of the 413 surgeries that used robotic guidance, 406 were via a minimally invasive approach. In 7 cases the surgeon switched to conventional screw placement, using a midline approach, due to referencing problems. A total of 2067 screws were implanted using robotic guidance, and 1857 screws were evaluated by postoperative CT. Of the 1857 screws, 1799 (96.9%) were classified as having an acceptable or good position, whereas 38 screws (2%) showed deviations of 3-6 mm and 20 screws (1.1%) had deviations > 6 mm. Nine misplaced screws, implanted in 7 patients, required revision surgery, yielding a screw revision rate of 0.48% of the screws and 7 of 406 (1.7%) of the patients. The mean +/- SD per-patient intraoperative fluoroscopy exposure was 114.4 (+/- 72.5) seconds for 5.1 screws on average and any further procedure required. Perioperative and direct postoperative complications included hemorrhage (2 patients, 0.49%) and wound infections necessitating surgical revision (20 patients, 4.9%). CONCLUSIONS The hexapod miniature robotic device proved to be a safe and robust instrument in all situations, including those in which patients were treated on an emergency basis. Placement accuracy was high; peri-and early postoperative complication rates were found to be lower than rates published in other series of percutaneous screw placement techniques. Intraoperative radiation exposure was found to be comparable to published values for other minimally invasive and conventional approaches
    corecore