59 research outputs found

    Corneal Inflammation After Miniature Keratoprosthesis Implantation

    Get PDF
    Citation: Crnej A, Omoto M, Dohlman TH, Dohlman CH, Dana R. Corneal inflammation after miniature keratoprosthesis implantation. Invest Ophthalmol Vis Sci

    Low-Cost and Readily Available Tissue Carriers for the Boston Keratoprosthesis: A Review of Possibilities

    Get PDF
    The Boston keratoprosthesis (B-KPro), currently the most commonly used artificial cornea worldwide, can provide rapid visual rehabilitation for eyes with severe corneal opacities not suitable for standard corneal transplantation. However, the B-KPro presently needs a corneal graft as a tissue carrier. Although corneal allograft tissue is readily available in the United States and other developed countries with established eye banks, the worldwide need vastly exceeds supply. Therefore, a simple, safe, and inexpensive alternative to corneal allografts is desirable for the developing world. We are currently exploring reasonable alternative options such as corneal autografts, xenografts, noncorneal autologous tissues, and laboratory-made tissue constructs, as well as modifications to corneal allografts, such as deep-freezing, glycerol-dehydration, gamma irradiation, and cross-linking. These alternative tissue carriers for the B-KPro are discussed with special regard to safety, practicality, and cost for the developing world

    Reliable intraocular pressure measurement using automated radio-wave telemetry

    Get PDF
    Purpose To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. Methods: The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. Results: On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg) and mean vehicle IOP (13.27±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute), during which the IOP is not expected to change. Conclusion: IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results

    Effect of Penetrating Keratoplasty and Keratoprosthesis Implantation on the Posterior Segment of the Eye

    Get PDF
    Citation:ÄŚrnej A, Omoto M, Dohlman TH, et al. Effect of penetrating keratoplasty and keratoprosthesis implantation on the posterior segment of the eye. Invest Ophthalmol Vis Sci. 2016;57:164357: -164857: . DOI:10.1167 PURPOSE. To compare the effects of post-penetrating keratoplasty (PK) and post-keratoprosthesis (KPro) surgery-related inflammation on the posterior segment of the eye and to assess inhibition of tumor necrosis factor alpha (TNFa) and interleukin-1 beta (IL-1b) on these effects. METHODS. BALB/C (syngeneic) or C57BL/6 (allogeneic) corneas were transplanted onto BALB/ C host beds as part of PK or miniature KPro (m-KPro) implantation. Intraocular pressure (IOP) was measured via an intracameral pressure sensor; tissues were harvested and analyzed 8 weeks after surgery. Expression of TNFa and IL-1b in the retina was analyzed using real-time quantitative (q)PCR. Optic nerve degeneration (axon count, circularity, and area) was assessed quantitatively using ImageJ software. After m-KPro implantation, mice were treated with saline, anti-TNFa, or anti-IL-1b antibody, and axonal loss was assessed after 10 weeks. RESULTS. Mean IOP was within normal limits in the operated and fellow eyes in all groups. The mRNA expression of TNFa and IL-1b was highest in m-KPro groups with either syngeneic or an allogeneic carrier. We observed optic nerve degeneration in both allogeneic PK and mKPro implanted eyes with an allogeneic carrier. However, TNFa blockade significantly reduced axonal loss by 35%. CONCLUSIONS. Allogeneic PK and m-KPro implants with an allogeneic carrier lead to chronic inflammation in the posterior segment of the eye, resulting in optic nerve degeneration. In addition, blockade of TNFa prevents axonal degeneration in this preclinical model of allogeneic m-KPro (alloKPro) implantation

    of the Boston Keratopros-thesis

    Get PDF
    Purpose: We tested the feasibility of using titanium to enhance adhesion of the Boston Keratoprosthesis (B-KPro), ultimately to decrease the risk of implant-associated complications. Methods: Cylindrical rods were made of poly(methyl methacrylate) (PMMA), PMMA coated with titanium dioxide (TiO 2 ) over a layer of polydopamine (PMMA TiO2 ), smooth (Ti) and sandblasted (Ti SB ) titanium, and titanium treated with oxygen plasma (Ti ox and Ti SBox ). Topography and surface chemistry were analyzed by scanning electron microscopy (SEM), atomic force microscopy (AFM), and X-ray photoelectron spectroscopy (XPS). Adhesion force between rods and porcine corneas was measured ex vivo. Titanium sleeves, smooth and sandblasted, were inserted around the stem of the B-KPro and implanted in rabbits. Tissue adhesion to the stem was assessed and compared to an unmodified B-Kpro after 1 month. Results: X-ray photoelectron spectroscopy demonstrated successful deposition of TiO 2 on polydopamine-coated PMMA. Oxygen plasma treatment did not change the XPS spectra of titanium rods (Ti and Ti SB ), although it increased their hydrophilicity. The materials did not show cell toxicity. After 14 days of incubation, PMMA TiO2 , smooth titanium treated with oxygen plasma (Ti ox ), and sandblasted titanium rods (Ti SB , Ti SBox ) showed significantly higher adhesion forces than PMMA ex vivo. In vivo

    Crosslinker-free collagen gelation for corneal regeneration

    Get PDF
    Development of an artificial cornea can potentially fulfil the demand of donor corneas for transplantation as the number of donors is far less than needed to treat corneal blindness. Collagen-based artificial corneas stand out as a regenerative option, having promising clinical outcomes. Collagen crosslinked with chemical crosslinkers which modify the parent functional groups of collagen. However, crosslinkers are usually cytotoxic, so crosslinkers need to be removed from implants completely before application in humans. In addition, crosslinked products are mechanically weak and susceptible to enzymatic degradation. We developed a crosslinker free supramolecular gelation strategy using pyrene conjugated dipeptide amphiphile (PyKC) consisting of lysine and cysteine; in which collagen molecules are intertwined inside the PyKC network without any functional group modification of the collagen. The newly developed collagen implants (Coll-PyKC) are optically transparent and can effectively block UV light, are mechanically and enzymatically stable, and can be sutured. The Coll-PyKC implants support the growth and function of all corneal cells, trigger anti-inflammatory differentiation while suppressing the pro-inflammatory differentiation of human monocytes. Coll-PyKC implants can restrict human adenovirus propagation. Therefore, this crosslinker-free strategy can be used for the repair, healing, and regeneration of the cornea, and potentially other damaged organs of the body

    Biocompatibility and biofilm inhibition of N,N-hexyl,methyl-polyethylenimine bonded to Boston Keratoprosthesis materials

    Get PDF
    The biocompatibility and antibacterial properties of N,N-hexyl,methyl-polyethylenimine (HMPEI) covalently attached to the Boston Keratoprosthesis (B-KPro) materials was evaluated. By means of confocal and electron microscopies, we observed that HMPEI-derivatized materials exert an inhibitory effect on biofilm formation by Staphylococcus aureus clinical isolates, as compared to the parent poly(methyl methacrylate) (PMMA) and titanium. There was no additional corneal epithelial cell cytotoxicity of HMPEI-coated PMMA compared to that of control PMMA in tissue cultures in vitro. Likewise, no toxicity or adverse reactivity was detected with HMPEI-derivatized PMMA or titanium compared to those of the control materials after intrastromal or anterior chamber implantation in rabbits in vivo.Massachusetts Institute of Technology. Institute for Soldier Nanotechnologies (Contract DAAD-19-D-0002

    Morphologic characteristics of posterior polymorphous dystrophy. A study of nine corneas and review of the literature

    Full text link
    Based on their own study of nine corneas with clinically documented posterior polymorphous dystrophy and a review of the literature, the authors describe the morphologic features of this entity. Study by phase contrast light microscopy and transmission and scanning electron microscopy found that changes were primarily in the endothelium and consisted of endothelial cell degeneration and loss with focal fibroblastic and epithelial-like cell transformation. Secondary alterations of Descemet's membrane were seen; they consisted of abnormal lamination with deposition of abnormal collagen material, particularly in the posterior collagen layer, and formation of guttate excrescences and pits.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/24707/1/0000128.pd
    • …
    corecore