12 research outputs found
DEAP-3600 Dark Matter Search
The DEAP-3600 experiment is located 2 km underground at SNOLAB, in Sudbury,
Ontario. It is a single-phase detector that searches for dark matter particle
interactions within a 1000-kg fiducial mass target of liquid argon. A first
generation prototype detector (DEAP-1) with a 7-kg liquid argon target mass
demonstrated a high level of pulse-shape discrimination (PSD) for reducing
/ backgrounds and helped to develop low radioactivity techniques
to mitigate surface-related backgrounds. Construction of the DEAP-3600
detector is nearly complete and commissioning is starting in 2014. The target
sensitivity to spin-independent scattering of Weakly Interacting Massive
Particles (WIMPs) on nucleons of 10 cm will allow one order of
magnitude improvement in sensitivity over current searches at 100 GeV WIMP
mass. This paper presents an overview and status of the DEAP-3600 project and
discusses plans for a future multi-tonne experiment, DEAP-50T.Comment: International Conference on High Energy Physics (ICHEP 2014),
Valencia, 201
Design and construction of the DEAP-3600 dark matter detector
The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The projected cross section sensitivity for DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons is 10−46cm2 for a 100 GeV/c2 WIMP mass with a fiducial exposure of 3 tonne-years. This paper describes the physical properties and construction of the DEAP-3600 detector
First results from the DEAP-3600 dark matter search with argon at SNOLAB
This paper reports the first results of a direct dark matter search with the DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg capacity. The LAr is viewed by an array of PMTs, which would register scintillation light produced by rare nuclear recoil signals induced by dark matter particle scattering. An analysis of 4.44 live days (fidicial exposure of 9.87 tonne days) of data taken during the initial filling phase demonstrates the best electronic recoil rejection using pulse-shape discrimination in argon, with leakage <1.2X107 (90% C.L.) between 15 and 31 keVee. No candidate signal events
are observed, which results in the leading limit on WIMP-nucleon spin-independent cross section on argon, <1.21044 cm2 for a 100 GeV/c2 WIMP mass (90% C.L.)
Search for dark matter with a 231-day exposure of liquid argon using DEAP-3600 at SNOLAB
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of LAr contained in a spherical acrylic vessel. This paper reports on the analysis of a 758  tonne⋅day exposure taken over a period of 231 live-days during the first year of operation. No candidate signal events are observed in the WIMP-search region of interest, which results in the leading limit on the WIMP-nucleon spin-independent cross section on a LAr target of 3.9×10−45  cm2 (1.5×10−44  cm2) for a 100  GeV/c2 (1  TeV/c2) WIMP mass at 90% C.L. In addition to a detailed background model, this analysis demonstrates the best pulse-shape discrimination in LAr at threshold, employs a Bayesian photoelectron-counting technique to improve the energy resolution and discrimination efficiency, and utilizes two position reconstruction algorithms based on the charge and photon detection time distributions observed in each photomultiplier tube
Recommended from our members
Design and construction of the DEAP-3600 dark matter detector
The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The projected cross section sensitivity for DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons is 10 cm for a 100 GeV/c WIMP mass with a fiducial exposure of 3 tonne-years. This paper describes the physical properties and construction of the DEAP-3600 detector. −46 2
Pulse-shape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from 39Ar beta decays and is suppressed using pulse-shape discrimination (PSD). We use two types of PSD estimator: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window around the event peak, and the log-likelihood-ratio, which compares the observed photon arrival times to a signal and a background model. We furthermore use two algorithms to determine the number of photons detected at a given time: (1) simply dividing the charge of each PMT pulse by the mean single-photoelectron charge, and (2) a likelihood analysis that considers the probability to detect a certain number of photons at a given time, based on a model for the scintillation pulse shape and for afterpulsing in the light detectors. The prompt-fraction performs approximately as well as the log-likelihood-ratio PSD algorithm if the photon detection times are not biased by detector effects. We explain this result using a model for the information carried by scintillation photons as a function of the time when they are detected
Pulse-shape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from 39Ar beta decays and is suppressed using pulse-shape discrimination (PSD). We use two types of PSD estimator: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window around the event peak, and the log-likelihood-ratio, which compares the observed photon arrival times to a signal and a background model. We furthermore use two algorithms to determine the number of photons detected at a given time: (1) simply dividing the charge of each PMT pulse by the mean single-photoelectron charge, and (2) a likelihood analysis that considers the probability to detect a certain number of photons at a given time, based on a model for the scintillation pulse shape and for afterpulsing in the light detectors. The prompt-fraction performs approximately as well as the log-likelihood-ratio PSD algorithm if the photon detection times are not biased by detector effects. We explain this result using a model for the information carried by scintillation photons as a function of the time when they are detected
Precision measurement of the specific activity of 39 Ar in atmospheric argon with the DEAP-3600 detector
The specific activity of the β decay of 39 Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 ± 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector is well-suited to measure the decay of 39 Ar owing to its very low background levels. This is achieved in two ways: it uses low background construction materials; and it uses pulse-shape discrimination to differentiate between nuclear recoils and electron recoils. With 167 live-days of data, the measured specific activity at the time of atmospheric extraction is (0.964 ± 0.001 stat ± 0.024 sys) Bq/kg atmAr , which is consistent with results from other experiments. A cross-check analysis using different event selection criteria and a different statistical method confirms the result
Precision measurement of the specific activity of 39 Ar in atmospheric argon with the DEAP-3600 detector
Abstract The specific activity of the β decay of 39 Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 ± 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector is well-suited to measure the decay of 39 Ar owing to its very low background levels. This is achieved in two ways: it uses low background construction materials; and it uses pulse-shape discrimination to differentiate between nuclear recoils and electron recoils. With 167 live-days of data, the measured specific activity at the time of atmospheric extraction is (0.964 ± 0.001 stat ± 0.024 sys ) Bq/kg atmAr , which is consistent with results from other experiments. A cross-check analysis using different event selection criteria and a different statistical method confirms the result