6 research outputs found
Safety and diagnostic yield of renal biopsy in the intensive care unit
Purpose Renal biopsy (RB) is occasionally performed in critically ill patients. The safety and impact of RB in this setting have not been reported. Methods A 10-year (2000–2009) retrospective multicentre study was conducted in ten French intensive care units (ICU) on patients who underwent RB during their management. Medical files were retrieved for data analysis. Results Seventy-seven patients underwent an RB of which 68 (88 %) were on a native kidney and 9 (12 %) on a transplanted kidney. Percutaneous ultrasound-guided RB was used in most cases (87 %). Fifty-seven per cent of the patients were on mechanical ventilation at the time of RB. RB-related complications occurred in 17 (22 %) patients, two were graded as severe (requirement for kidney embolization, eventually successful). In 35 (51 %) non-transplanted patients, RB established a specific diagnosis other than acute tubular necrosis (ATN), which was diagnosed in only 18 % of patients. In the remaining patients, only non-specific lesions were observed. Therapeutic modifications followed RB in 14 (21 %) non-transplanted patients. Presence of signs of systemic disease involving the renal tract, occurrence of renal failure before hospital admission, and absence of any factor usually associated with ATN significantly predicted the presence of a specific diagnosis at RB other than ATN. Conclusions In this cohort, the contribution of RB to diagnosis and treatment was undeniable, but at the expense of frequent adverse events although most of them were not considered severe
ПРОТЕЗИРОВАНИЕ АОРТАЛЬНОГО КЛАПАНА АУТОПЕРИКАРДОМ БЕЗ ИСПОЛЬЗОВАНИЯ ШАБЛОНОВ: НЕПОСРЕДСТВЕННЫЕ И СРЕДНЕОТДАЛЕННЫЕ РЕЗУЛЬТАТЫ
HighlightsWe have described the outcomes of aortic valve replacement using autologous pericardium without special templates. Although S. Ozaki is considered by many to be the founder of neocuspidization technique, the methods for sizing of the neocusps were proposed long before him. The method of the Japanese professor involves using special templates. This article presents a mathematical formula to calculate neocusps` size, which significantly simplifies the procedure, and makes it possible to perform it in centers that do not possess Ozaki templates. Abstract Aim: To describe an original technique of aortic valve replacement using autologous pericardium without templates. The calculation of the neocusps` size is based on the diameter of aortic annulus, which can be estimated both intraoperatively and preoperatively, helps to reduce the duration of surgery, CPB time and myocardial ischemia, and lower the rates of late complications.Methods: The prospective study included 34 patients with aortic valve disease admitted to the Cardiac Surgical Department of the University Clinical Hospital No.1 of the First Moscow State Medical University named after I.M. Sechenov, Ministry of Health of Russia in the period from January 2020 to March 2023. The mean age of the patients was 51±17 years (from 19 to 78 years). Gender distribution in the total group was as follows: male 50% (n = 17), female 50% (n = 17). All patients underwent aortic valve replacement using autologous pericardium without templates (by calculating the neocusps` size). Isolated aortic valve replacement was performed in 17 patients (50%), ascending aorta replacement in 11 patients (32.3%), mitral valve intervention in 5 (14.7%), coronary artery bypass grafting in 3 (8.8%) cases. 11 patients (32.3%) had aortic valve stenosis, 4 patients (11.7%) had insufficiency, and 19 patients (55.8%) had both stenosis and insufficiency. Bicuspid aortic valve was detected in 18 patients (52.9%). All patients were divided into two groups: Komarov (aortic valve replacement only) and Komarov Plus (aortic valve replacement and treatment for concomitant cardiac pathology).Results: There were no cases of conversion to traditional aortic valve replacement using prosthetic valves. There were 2 cases of in-hospital mortality; according to medical records, death in both cases was due to complications provoked by double pneumonia caused by SARS-CoV-2. 1 patient required reoperation 4 months after the intervention due endocarditis caused by Streptococcus viridans. In the midterm follow-up period, hemodynamic parameters such as peak gradient, mean gradient, and peak velocity were 11.96±4.70 mm Hg, 5.88±2.07 mm Hg, 168.19±30.56 mm Hg.Conclusions: The obtained valve prosthesis is anatomically analogous to the native valve and provides reliable peak pressure reduction, no postoperative regurgitation, and increased effective orifice area. The proposed method is safe and can serve as an alternative to the Ozaki procedure, in which the neocusps are outlined using special templates.Основные положения Продемонстрированы результаты протезирования аортального клапана аутоперикардом без использования шаблонов. Родоначальником неокуспидизации принято считать S. Ozaki, однако методы расчета неостворки из перикарда предложены задолго до него. Методика японского профессора заключается в использовании специальных шаблонов. В данной статье представлен математический расчет створки, выполненный хирургами Сеченовского Университета, позволяющий не только существенно упростить процедуру, но и выполнять ее в тех центрах, где шаблонов Ozaki нет. Резюме Цель: Описана оригинальная методика полной реконструкции аортального клапана аутоперикардом. Расчет формы неостворок осуществлен на основании данных о диаметре фиброзного кольца, которые могут быть получены как во время, так и до операции, что позволяет сократить время вмешательства, искусственного кровообращения и ишемии миокарда, а в конечном итоге добиться снижения ишемии головного мозга и снизить вероятность поздних осложнений.Материалы и методы: Проведено проспективное исследование 34 пациентов, оперированных по поводу порока аортального клапана в кардиохирургическом отделении Университетской клинической больницы № 1 ФГАОУ ВО Первый МГМУ им. И.М. Сеченова Минздрава России (Сеченовский Университет) в период с января 2020 г. по март 2023 г. Средний период наблюдения для всей когорты составил 14,1±7,7 мес. Средний возраст больных – 51±17 лет (19–78 лет). Гендерное распределение в общей группе: мужской пол – 50% (n = 17), женский – 50% (n = 17). Всем пациентам выполнено протезирование аортального клапана аутоперикардом без использования шаблонов (расчетным способом). 17 (50%) больным проведена изолированная коррекция порока аортального клапана, 11 (32,3%) – протезирование восходящей аорты, 5 (14,7%) – вмешательство на митральном клапане, в 3 (8,8%) случаях выполнено коронарное шунтирование. Стеноз аортального клапана отмечен у 11 (32,3%) пациентов, недостаточность – у 4 (11,7%), стеноз и недостаточность – у 19 (55,8%). Двустворчатый аортальный клапан выявлен у 18 (52,9%) больных. Все пациенты разделены на две группы: Komarov (изолированная коррекция порока аортального клапана) и Komarov Plus (коррекция порока аортального клапана с сопутствующей кардиальной патологией).Результаты: Не зарегистрировано случаев конверсии в стандартное протезирование аортального клапана. Зафиксировано два случая госпитальной летальности; по данным патологоанатомического заключения, смерть в обоих случаях наступила из-за осложнений, спровоцированных двусторонней полисегментарной пневмонией, вызванной SARS-CoV-2. Одному пациенту через 4 мес. после вмешательства потребовалась повторная операция вследствие развившегося эндокардита, возбудитель Streptococcus viridans. В среднеотдаленном периоде гемодинамические показатели, такие как пиковый градиент, средний градиент и пиковая скорость, составили 11,96±4,70, 5,88±2,07 мм рт. ст. и 168,19±30,56 см/с.Заключение: Конечный вид протеза служит анатомическим аналогом нативного клапана и обеспечивает достоверное снижение пикового давления, отсутствие регургитации на клапане после операции и увеличение площади эффективного отверстия. Данный метод можно рассматривать как безопасную альтернативу процедуре Ozaki, при которой створки выкраивают с помощью специальных шаблонов
Circulating adrenomedullin estimates survival and reversibility of organ failure in sepsis: the prospective observational multinational Adrenomedullin and Outcome in Sepsis and Septic Shock-1 (AdrenOSS-1) study
Background: Adrenomedullin (ADM) regulates vascular tone and endothelial permeability during sepsis. Levels of circulating biologically active ADM (bio-ADM) show an inverse relationship with blood pressure and a direct relationship with vasopressor requirement. In the present prospective observational multinational Adrenomedullin and Outcome in Sepsis and Septic Shock 1 (, AdrenOSS-1) study, we assessed relationships between circulating bio-ADM during the initial intensive care unit (ICU) stay and short-term outcome in order to eventually design a biomarker-guided randomized controlled trial. Methods: AdrenOSS-1 was a prospective observational multinational study. The primary outcome was 28-day mortality. Secondary outcomes included organ failure as defined by Sequential Organ Failure Assessment (SOFA) score, organ support with focus on vasopressor/inotropic use, and need for renal replacement therapy. AdrenOSS-1 included 583 patients admitted to the ICU with sepsis or septic shock. Results: Circulating bio-ADM levels were measured upon admission and at day 2. Median bio-ADM concentration upon admission was 80.5 pg/ml [IQR 41.5-148.1 pg/ml]. Initial SOFA score was 7 [IQR 5-10], and 28-day mortality was 22%. We found marked associations between bio-ADM upon admission and 28-day mortality (unadjusted standardized HR 2.3 [CI 1.9-2.9]; adjusted HR 1.6 [CI 1.1-2.5]) and between bio-ADM levels and SOFA score (p < 0.0001). Need of vasopressor/inotrope, renal replacement therapy, and positive fluid balance were more prevalent in patients with a bio-ADM > 70 pg/ml upon admission than in those with bio-ADM ≤ 70 pg/ml. In patients with bio-ADM > 70 pg/ml upon admission, decrease in bio-ADM below 70 pg/ml at day 2 was associated with recovery of organ function at day 7 and better 28-day outcome (9.5% mortality). By contrast, persistently elevated bio-ADM at day 2 was associated with prolonged organ dysfunction and high 28-day mortality (38.1% mortality, HR 4.9, 95% CI 2.5-9.8). Conclusions: AdrenOSS-1 shows that early levels and rapid changes in bio-ADM estimate short-term outcome in sepsis and septic shock. These data are the backbone of the design of the biomarker-guided AdrenOSS-2 trial. Trial registration: ClinicalTrials.gov, NCT02393781. Registered on March 19, 2015
Возможности портативного регистратора электрокардиограммы и пульсовой волны в выявлении систолической дисфункции левого желудочка
Highlights. The article presents a novel and unique method for assessment of left ventricular systolic disfunction using electrocardiography and photoplethysmography data. This method will improve and simplify the detection of cardiovascular diseases.Aim. To evaluate left ventricular (LV) systolic function using electrocardiogram (ECG) and photoplethysmogram (PPG) signals recorded by a single-channel ECG and PPG-based monitor.Methods. The prospective study included 489 patients over 18 years old with various cardiovascular diseases. All participants underwent echocardiography to determine the main indicators of LV systolic function: LV ejection fraction (EF), LV outflow tract velocity time integral (LVOT VTI), and global longitudinal strain (GLS). Moreover, all patients underwent 1-lead ECG and PPG recording using a single-channel ECG and PPG-based monitor (CardioQvark). The obtained data were analyzed, and ROC curve analysis was performed.Results. We have identified ECG and PPG parameters associated with a decrease in LV contractile function. During the analysis, the ECG, T-wave amplitude (TA) and RonsF parameters showed the highest diagnostic accuracy. With EF below 55%, the area under the ROC curve (AUC) was 0.822, sensitivity (Se) 80%, specificity (Sp) 69% in EF below 55% in TA; in RonsF AUC was 0.743, Se 81%, Sp 77%. With EF below 40%, AUC was 0.915, Se 85%, Sp 83% in TA, and in RonsF AUC was 0.844, Se 82%, Sp 82%. Diagnostic accuracy of ECG signals in case of LVOT VTI lower than 16 cm was measured: TA (AUC 0.755, Se 82%, Sp 70%), RonsF (AUC 0.620, Se 77%, Sp 72%). PPG signals were not significantly associated with reduced EF; however, the pulse wave parameters were associated with lower LVOT VTI: in DP-B0 AUC was 0.687, Se 71%, Sp 74%. The combination of ECG and PPG signals was significantly associated with EF below 40% (RonsF * DP-SEP (AUC 0.877, Se 86%, Sp 85%). ECG and PPG signals were not associated with LV GLS.Conclusion. Assessment of LV systolic function can be performed by analyzing ECG and PPG signals recorded using a portable single-channel CardioQvark monitor.Основные положения. Описана возможность диагностики снижения систолической функции левого желудочка по данным электро- и фотоплетизмограммы. Разработка метода оценки систолической функции левого желудочка на основе электро- и фотоплетизмограммы позволит улучшить и упростить выявление сердечно-сосудистых заболеваний. Метод оценки систолической функции сердца, изложенный в исследовании, представлен впервые и является уникальным.Цель. Оценка систолической функции левого желудочка (ЛЖ) на основе параметров электро- (ЭКГ) и фотоплетизмограммы (ФПГ), зарегистрированных одноканальным монитором ЭКГ с функцией фотоплетизмографии.Материалы и методы. В проспективное исследование включено 489 пациентов в возрасте старше 18 лет, имеющих заболевания сердечно-сосудистой системы. Всем участникам исследования выполнена эхокардиография с определением основных показателей систолической функции ЛЖ: фракции выброса (ФВ) ЛЖ, интеграла линейной скорости кровотока в выносящем тракте ЛЖ (VTI в ВТЛЖ), глобальной деформации ЛЖ (GLS). Также всем больным проведена регистрация ЭКГ в I отведении и ФПГ с использованием монитора ЭКГ с функцией фотоплетизмографии (CardioQVARK). Проведены расчет всех полученных параметров, затем ROC-анализ данных.Результаты. Выявлены параметры ЭКГ и ФПГ, ассоциированные со снижением сократительной функции ЛЖ. При анализе ЭКГ параметры TA (амплитуда T-волны) и RonsF (частота максимальной энергии переднего фронта R-волны) имели наибольшую диагностическую точность. При ФВ менее 55% для TA площадь под ROC-кривой (AUC) составила 0,822, чувствительность (Se) 80%, специфичность (Sp) 69%, а для параметра RonsF – AUC 0,743, Se 81%, Sp 77%. При ФВ менее 40%: AUC для TA составила 0,915, Se 85%, Sp 83%, для RonsF – AUC 0,844, Se 82%, Sp 82%. Диагностическая точность параметров ЭКГ при снижении VTI в ВТЛЖ менее 16 см: TA (AUC 0,755, Se 82%, Sp 70%), RonsF (AUC 0,620, Se 77%, Sp 72%). При оценке параметров ФПГ достоверной взаимосвязи со снижением ФВ не выявлено, однако параметры пульсовой волны ассоциированы с уменьшением VTI в ВТЛЖ: для DP-B0 AUC 0,687, Se 71%, Sp 74%. Комбинации параметров ЭКГ и ФПГ достоверно взаимосвязаны со значением ФВ менее 40% (RonsF*DP-SEP (AUC 0,877, Se 86%, Sp 85%)). Взаимосвязи параметров ЭКГ и ФПГ со значением GLS ЛЖ не обнаружено.Заключение. Определение систолической функции ЛЖ возможно при анализе параметров ЭКГ и ФПГ, зарегистрированных с помощью портативного одноканального монитора CardioQVARK