    A Formal Verification Methodology for DDD Mode Pacemaker Control Programs

    No full text
    Pacemakers are safety-critical devices whose faulty behaviors can cause harm or even death. Often these faulty behaviors are caused due to bugs in programs used for digital control of pacemakers. We present a formal verification methodology that can be used to check the correctness of object code programs that implement the safety-critical control functions of DDD mode pacemakers. Our methodology is based on the theory of Well-Founded Equivalence Bisimulation (WEB) refinement, where both formal specifications and implementation are treated as transition systems. We develop a simple and general formal specification for DDD mode pacemakers. We also develop correctness proof obligations that can be applied to validate object code programs used for pacemaker control. Using our methodology, we were able to verify a control program with millions of transitions against the simple specification with only 10 transitions. Our method also found several bugs during the verification process

    Label-Free Biosensing Method for the Detection of a Pancreatic Cancer Biomarker Based on Dielectrophoresis Spectroscopy

    No full text
    We show that negative dielectrophoresis (DEP) spectroscopy is an effective transduction mechanism of a biosensor for the diagnosis and prognosis of pancreatic cancer using the biomarker CA 19-9. A substantial change in the negative DEP force applied to functionalized polystyrene microspheres (PM) was observed with respect to both the concentration level of the pancreatic cancer biomarker CA 19-9 and the frequency of the electric field produced by a pearl shaped interdigitated gold micro-electrode. The velocity of repulsion of a set of PM functionalized to a monoclonal antibody to CA 19-9 was calculated for several concentration cutoff levels of CA 19-9, including 0 U/mL and 37 U/mL, at the frequency range from 0.5 to 2 MHz. The velocity of repulsion of the PM from the electrode was determined using a side illumination and an automated software using a real-time image processing technique that captures the Mie scattering from the PM. Since negative DEP spectroscopy is an effective transduction mechanism for the detection of the cutoff levels of CA 19-9, it has the potential to be used in the early stage diagnosis and in the prognosis of pancreatic cancer

    Evaluating the nitrification inhibition potential of selected botanicals and their non-target effects

    No full text
    Nitrification inhibitors (NI) are aimed at improving N-fertilizer use efficiency in cropping systems. This study aimed to assess the nitrification inhibition potential and non-target effects of dry leaf powders (botanicals) of ten plant species [neem (Azadirachta indica), lantana (Lantana camara), karanda (Pongamia pinnata), Brachiaria humidicola, cinnamon (Cinnamomum verum), clove (Syzygium aromaticum), wild-sunflower (Tithonia diversifolia), mee (‎Madhuca longifolia), nutmeg (Myristica fragrans) and pepper (Piper nigram)]. The effect of botanicals on the growth of three ammonia oxidizing bacteria isolates (M4, M5 and M7) and NO3The accepted manuscript in pdf format is listed with the files at the bottom of this page. The presentation of the authors' names and (or) special characters in the title of the manuscript may differ slightly between what is listed on this page and what is listed in the pdf file of the accepted manuscript; that in the pdf file of the accepted manuscript is what was submitted by the author

    A Miniaturized MicroRNA Sensor Identifies Targets Associated with Weight Loss in a Diet and Exercise Intervention among Healthy Overweight Individuals

    No full text
    Weight loss through dietary and exercise intervention is commonly prescribed but is not effective for all individuals. Recent studies have demonstrated that circulating microRNA (miR) biomarkers could potentially be used to identify individuals who will likely lose weight through diet and exercise and attain a healthy body weight. However, accurate detection of miRs in clinical samples is difficult, error-prone, and expensive. To address this issue, we recently developed iLluminate—a low-cost and highly sensitive miR sensor suitable for point-of-care testing. To investigate if miR testing and iLluminate can be used in real-world obesity applications, we developed a pilot diet and exercise intervention and utilized iLluminate to evaluate miR biomarkers. We evaluated the expression of miRs-140, -935, -let-7b, and -99a, which are biomarkers for fat loss, energy metabolism, and adipogenic differentiation. Responders lost more total mass, tissue mass, and fat mass than non-responders. miRs-140, -935, -let-7b, and -99a, collectively accounted for 6.9% and 8.8% of the explained variability in fat and lean mass, respectively. At the level of the individual coefficients, miRs-140 and -935 were significantly associated with fat loss. Collectively, miRs-140 and -935 provide an additional degree of predictive capability in body mass and fat mass alternations

    Shrink-induced sorting using integrated nanoscale magnetic traps

    No full text
    We present a plastic microfluidic device with integrated nanoscale magnetic traps (NSMTs) that separates magnetic from non-magnetic beads with high purity and throughput, and unprecedented enrichments. Numerical simulations indicate significantly higher localized magnetic field gradients than previously reported. We demonstrated >20 000-fold enrichment for 0.001% magnetic bead mixtures. Since we achieve high purity at all flow-rates tested, this is a robust, rapid, portable, and simple solution to sort target species from small volumes amenable for point-of-care applications. We used the NSMT in a 96 well format to extract DNA from small sample volumes for quantitative polymerase chain reaction (qPCR)