12 research outputs found
Evaluating techniques to improve visual performance with and assessment of premium intraocular lenses
Premium Intraocular Lenses (IOLs) such as toric IOLs, multifocal IOLs (MIOLs) and accommodating IOLs (AIOLs) can provide better refractive and visual outcomes compared to standard monofocal designs, leading to greater levels of post-operative spectacle independence. The principal theme of this thesis relates to the development of new assessment techniques that can help to improve future premium IOL design. IOLs designed to correct astigmatism form the focus of the first part of the thesis. A novel toric IOL design was devised to decrease the effect of toric rotation on patient visual acuity, but found to have neither a beneficial or detrimental impact on visual acuity retention. IOL tilt, like rotation, may curtail visual performance; however current IOL tilt measurement techniques require the use of specialist equipment not readily available in most ophthalmological clinics. Thus a new idea that applied Pythagoras’s theory to digital images of IOL optic symmetricality in order to calculate tilt was proposed, and shown to be both accurate and highly repeatable. A literature review revealed little information on the relationship between IOL tilt, decentration and rotation and so this was examined. A poor correlation between these factors was found, indicating they occur independently of each other. Next, presbyopia correcting IOLs were investigated. The light distribution of different MIOLs and an AIOL was assessed using perimetry, to establish whether this could be used to inform optimal IOL design. Anticipated differences in threshold sensitivity between IOLs were not however found, thus perimetry was concluded to be ineffective in mapping retinal projection of blur. The observed difference between subjective and objective measures of accommodation, arising from the influence of pseudoaccommodative factors, was explored next to establish how much additional objective power would be required to restore the eye’s focus with AIOLs. Blur tolerance was found to be the key contributor to the ocular depth of focus, with an approximate dioptric influence of 0.60D. Our understanding of MIOLs may be limited by the need for subjective defocus curves, which are lengthy and do not permit important additional measures to be undertaken. The use of aberrometry to provide faster objective defocus curves was examined. Although subjective and objective measures related well, the peaks of the MIOL defocus curve profile were not evident with objective prediction of acuity, indicating a need for further refinement of visual quality metrics based on ocular aberrations. The experiments detailed in the thesis evaluate methods to improve visual performance with toric IOLs. They also investigate new techniques to allow more rapid post-operative assessment of premium IOLs, which could allow greater insights to be obtained into several aspects of visual quality, in order to optimise future IOL design and ultimately enhance patient satisfaction
Initial experience using a femtosecond laser cataract surgery system at a UK National Health Service cataract surgery day care centre
© 2019 The Author(s). This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/OBJECTIVES: To describe the initial outcomes following installation of a cataract surgery laser system.SETTING: National Health Service cataract surgery day care unit in North London, UK.PARTICIPANTS: 158 eyes of 150 patients undergoing laser-assisted cataract surgery.INTERVENTIONS: Laser cataract surgery using the AMO Catalys femtosecond laser platform.PRIMARY AND SECONDARY OUTCOME MEASURES: PRIMARY OUTCOME MEASURE: intraoperative complications including anterior and posterior capsule tears.SECONDARY OUTCOME MEASURES: docking to the laser platform, successful treatment delivery, postoperative visual acuities.RESULTS: Mean case age was 67.7±10.8 years (range 29-88 years). Docking was successful in 94% (148/158 cases), and in 4% (6/148 cases) of these, the laser delivery was aborted part way during delivery due to patient movement. A total of 32 surgeons, of grades from junior trainee to consultant, performed the surgeries. Median case number per surgeon was 3 (range from 1-20). The anterior capsulotomy was complete in 99.3% of cases, there were no anterior capsule tears (0%). There were 3 cases with posterior capsule rupture requiring anterior vitrectomy, and 1 with zonular dialysis requiring anterior vitrectomy (4/148 eyes, 2.7%). These 4 cases were performed by trainee surgeons, and were either their first laser cataract surgery (2 surgeons) or their first and second laser cataract surgeries (1 surgeon).CONCLUSIONS: Despite the learning curve, docking and laser delivery were successfully performed in almost all cases, and surgical complication rates and visual outcomes were similar to those expected based on national data. Complications were predominately confined to trainee surgeons, and with the exception of intraoperative pupil constriction appeared unrelated to the laser-performed steps.Peer reviewe
Impact of soft contact lens edge design and mid-peripheral lens shape on the epithelium and its indentation with lens mobility
Purpose. To evaluate the influence of soft contact lens midperipheral shape profile and edge design on the apparent epithelial thickness and indentation of the ocular surface with lens movement. Methods. Four soft contact lens designs comprising of two different plano midperipheral shape profiles and two edge designs (chiseled and knife edge) of silicone-hydrogel material were examined in 26 subjects aged 24.7 ± 4.6 years, each worn bilaterally in randomized order. Lens movement was imaged enface on insertion, at 2 and 4 hours with a high-speed, high-resolution camera simultaneous to the cross-section of the edge of the contact lens interaction with the ocular surface captured using optical coherence tomography (OCT) nasally, temporally, and inferiorly. Optical imaging distortions were individually corrected for by imaging the apparent distortion of a glass slide surface by the removed lens. Results. Apparent epithelial thickness varied with edge position (P < 0.001). When distortion was corrected for, epithelial indentation decreased with time after insertion (P = 0.010), changed after a blink (P < 0.001), and varied with position on the lens edge (P < 0.001), with the latter being affected by midperipheral lens shape profile and edge design. Horizontal and vertical lens movement did not change with time postinsertion. Vertical motion was affected by midperipheral lens shape profile (P < 0.001) and edge design (P < 0.001). Lens movement was associated with physiologic epithelium thickness for lens midperipheral shape profile and edge designs. Conclusions. Dynamic OCT coupled with high-resolution video demonstrated that soft contact lens movement and image-corrected ocular surface indentation were influenced by both lens edge design and midperipheral lens shape profiles
Factors Influencing Pseudo-Accommodation—The Difference between Subjectively Reported Range of Clear Focus and Objectively Measured Accommodation Range
The key determinants of the range of clear focus in pre-presbyopes and their relative contributions to the difference between subjective range of focus and objective accommodation assessments have not been previously quantified. Fifty participants (aged 33.0 ± 6.4 years) underwent simultaneous monocular subjective (visual acuity measured with an electronic test-chart) and objective (dynamic accommodation measured with an Aston open-field aberrometer) defocus curve testing for lenses between +2.00 to −10.00 DS in +0.50 DS steps in a randomized order. Pupil diameter and ocular aberrations (converted to visual metrics normalized for pupil size) at each level of blur were measured. The difference between objective range over which the power of the crystalline lens changes and the subjective range of clear focus was quantified and the results modelled using pupil size, refractive error, tolerance to blur, and ocular aberrations. The subjective range of clear focus was principally accounted for by age (46.4%) and pupil size (19.3%). The objectively assessed accommodative range was also principally accounted for by age (27.6%) and pupil size (15.4%). Over one-quarter (26.0%) of the difference between objective accommodation and subjective range of clear focus was accounted for by age (14.0%) and spherical aberration at maximum accommodation (12.0%). There was no significant change in the objective accommodative response (F = 1.426, p = 0.229) or pupil size (F = 0.799, p = 0.554) of participants for levels of defocus above their amplitude of accommodation. Pre-presbyopes benefit from an increased subjective range of clear vision beyond their objective accommodation due in part to neural factors, resulting in a measured depth-of-focus of, on average, 1.0
BCLA CLEAR presbyopia: Management with intraocular lenses
Cataract surgery including intraocular lens (IOL) insertion, has been refined extensively since the first such procedure by Sir Harold Ridley in 1949. The intentional creation of monovision with IOLs using monofocal IOL designs has been reported since 1984. The first reported implantation of multifocal IOLs was published in 1987. Since then, various refractive and or diffractive multifocal IOLs have been commercialised. Most are concentric, but segmented IOLs are also available. The most popular are trifocal designs (overlaying two diffractive patterns to achieve additional focal planes at intermediate and near distances) and extended depth of focus designs which leave the patient largely spectacle independent with the reduced risk of bothersome contrast reduction and glare. As well as mini-monovision, surgical strategies to minimise the impact of presbyopia with IOLs includes mixing and matching lenses between the eyes and using IOLs whose power can be adjusted post-implantation. Various IOL designs to mimic the accommodative process have been tried including hinge optics, dual optics, lateral shifts lenses with cubic-type surfaces, lens refilling and curvature changing approaches, but issues in maintaining the active mechanism with post-surgical fibrosis, without causing ocular inflammation, remain a challenge. With careful patient selection, satisfaction rates with IOLs to manage presbyopia are high and anatomical or physiological complications rates are no higher than with monofocal IOLs
International multi-centre study of potential benefits of ultraviolet radiation protection using contact lenses
Purpose To examine the effects of long-term ultraviolet radiation (UVR) blocking wearing contact lenses on ocular surface health, eye focus and macular pigment. Method 210 pre-presbyopic patients were recruited from Birmingham UK, Brisbane Australia, Hong Kong China, Houston USA and Waterloo Canada (n = 42 at each site). All patients had worn contact lenses for ≥ 5 years, half (test group) of a material incorporating a UVR-blocking filter. Ocular health was assessed using slit-lamp biomicroscopy and UV autofluorescence. Accommodation was measured subjectively with a push-up test and overcoming lens-induced defocus. Objective stimulus response and dynamic measures of the accommodative response were quantified with an open-field aberrometer. Macular pigment optical density (MPOD) was assessed using heterochromatic flicker photometry (MPS II). Results The two groups of participants were matched for age, sex, race, body-mass-index, diet, lifestyle, UVR exposure, refractive error and visual acuity. Limbal (p = 0.035), but not bulbar conjunctival redness (p = 0.903) was lower in eyes that had worn UVR-blocking contact lenses compared to controls. The subjective (8.0 ± 3.7D vs 7.3 ± 3.3D; p = 0.125) and objective (F = 1.255, p = 0.285) accommodative response was higher in the test group, but the differences did not reach significance. However, the accommodative latency was shorter in eyes that had worn UVR-blocking contact lenses (p = 0.003). There was no significant different in MPOD with UVR filtration (p = 0.869). Conclusions Blocking the transmission of UVR is beneficial in maintaining the eye’s ability to focus, suggesting that presbyopia maybe delayed in long-term UVR-blocking contact lenses wearers. These lenses also provide protection to the critical limbal region
Effect of Heating and Massaging of Meibomian Glands on Their Imaging
© 2024 Author(s). Published by MDPI on behalf of the Lithuanian University of Health Sciences. This is an open access article distributed under the Creative Commons Attribution License, to view a copy of the license, see: https://creativecommons.org/licenses/by/4.0/Background and Objectives: Infrared light is used to image the Meibomian glands through their thermal profile. This study aimed to investigate the effects of a combination of heating and an eyelid massage on Meibomian gland visibility and tear film parameters. Materials and Methods: Twenty-four participants (26 ± 6.9 years) were enrolled in this prospective study, which involved imaging the Meibomian glands of both the lower and upper eyelid and assessing the non-invasive breakup time (NIBUT), tear meniscus height (TMH), and blink rate (using the CA-800, Topcon) at baseline after five minutes of eyelid warming followed by a five-minute eyelid massage. The second session, which was randomised in sequence, repeated the same measurements but without the inclusion of any eyelid warming or massage as the control condition. Results: While there was no change in lower lid Meibomian gland appearance as a result of eyelid heating, eyelid massage, or multiple lid eversion (median 2.0, range 0.0 to 4.0; p = 0.782), there was a change in upper lid appearance 5 min after heating and lid massage (p = 0.025), but again, multiple lid eversion had no effect (p > 0.05). The NIBUT decreased on second lid eversion (p = 0.049), although this was not evident on the third lid eversion (p = 0.090). The effect on NIBUT was also apparent with heating (p = 0.034 immediately after) but was sustained with 5 min of eyelid massage (p = 0.031). The TMH increased with heating (p 0.05). The blink rate was unaffected by heating, eyelid massage, or multiple eversions of the eyelids (median 24 blinks/min, range 8 to 59 blinks/min; p = 0.61). Conclusions: Eyelid warming can increase the visibility of the Meibomian glands, although this effect was only observed with upper lid imaging and the effect dissipated after 5 min of eyelid massage. Warming and massage also disrupt the tear film, as does multiple lid eversion, emphasising the need to use the least invasive tear film assessment techniques first.Peer reviewe
Demographic and lifestyle risk factors of dry eye disease subtypes:A cross-sectional study
Purpose: To evaluate demographic and lifestyle factors associated with aqueous deficient and evaporative dry eye disease. Methods: A total of 1125 general public visitors (707 females, mean ± SD age, 33 ± 21, range 5–90 years) at the Royal Society Summer Science Exhibition were recruited in a cross-sectional study. A demographic and lifestyle factor questionnaire was administered, and dry eye symptomology (DEQ-5 score), ocular surface characteristics (conjunctival hyperaemia, and infrared meibography), and tear film parameters (tear meniscus height, non-invasive breakup time, and lipid layer grade) were evaluated for the left eye of each participant within a single session. The diagnostic criteria for dry eye disease subtypes were adapted from the rapid non-invasive dry eye assessment algorithm. Results: Overall, 428 (38%) participants fulfilled the diagnostic criteria for dry eye disease, 161 (14%) with aqueous deficient dry eye disease, and 339 (30%) with evaporative dry eye disease. Multivariate logistic regression demonstrated that advancing age, female sex, reduced sleep duration, higher psychological stress, and poorer self-perceived health status were independently associated with aqueous deficient dry eye disease (all p < 0.05). Significant risk factors for evaporative dry eye disease included advancing age, East and South Asian ethnicity, contact lens wear, increased digital device screen exposure, higher psychological stress, and poorer self-perceived health status (all p < 0.05). Conclusions: Both subtypes of dry eye disease were associated with several unique and shared demographic and lifestyle factors. The findings of this study could inform future research design investigating the utility of targeted screening and risk factor modification for the prevention and management of dry eye disease
Impact of digital screen use and lifestyle factors on dry eye disease in the paediatric population
Short Communicatio